• Title/Summary/Keyword: Fire fighting objects

Search Result 13, Processing Time 0.023 seconds

Study on the Improvement of Inspection-Related Regulation of Fire Protection Systems and Equipment - Focused on the Fire Administration Process - (소방시설 자체점검 관계법령의 개선방안에 대한 연구 - 소방행정프로세서를 중심으로 -)

  • Lee, Jong Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.188-193
    • /
    • 2019
  • In the past, the risk of fire and the rate of fire occurrence has increased gradually as the quality of life improved due to rapid economic growth, and the government enacted Fire Prevention Act. The existing inspection method was revised considering the rapid increase in the number of fire-fighting objects(hereinafter referred to as specific fire-fighting objects) that require the installation of fire-fighting facilities, and has been applied to this day. On the other hand, unlike the rapid increase in specific fire-fighting objects and the development of fire prevention technologies, the scope of work and inspections by unsuitable inspectors caused a large fire accident, which required improvement of the related laws. This study evaluated, the Act on the relationship of firefighting facilities, which had been implemented previously to identify fire victims, save lives, secure independence of fire inspection agencies, and ensure the accuracy of fire prevention actions.

Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage (화재피해 감소 위한 자동소화장치 적용범위 개선)

  • Baek, Chang Sun;Park, In Seon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

Analyses of the Outbreaking Fires according to the Industrialization in Korea (산업화에 따른 한국의 화재발생 추이 분석)

  • Kim, H.B.;Lee, J.I.;Keon, H.S.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.127-137
    • /
    • 2007
  • In our country, a number of fire outbreaking had been increased suddenly for 20 years from beginning of 1980's to 2001. That was related with the focus of economic policy, the rapid increasing of fire fighting objects, the change of life environment, and the increasement of usage of energy. Accordingly, we tried to enforce the function of feedback effect of fire prevention policies with analysing the trends of fire occurring from 1950's to 2006 and the correct statistical analysis.

  • PDF

Efficient Forest Fire Detection using Rule-Based Multi-color Space and Correlation Coefficient for Application in Unmanned Aerial Vehicles

  • Anh, Nguyen Duc;Van Thanh, Pham;Lap, Doan Tu;Khai, Nguyen Tuan;Van An, Tran;Tan, Tran Duc;An, Nguyen Huu;Dinh, Dang Nhu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.2
    • /
    • pp.381-404
    • /
    • 2022
  • Forest fires inflict great losses of human lives and serious damages to ecological systems. Hence, numerous fire detection methods have been proposed, one of which is fire detection based on sensors. However, these methods reveal several limitations when applied in large spaces like forests such as high cost, high level of false alarm, limited battery capacity, and other problems. In this research, we propose a novel forest fire detection method based on image processing and correlation coefficient. Firstly, two fire detection conditions are applied in RGB color space to distinguish between fire pixels and the background. Secondly, the image is converted from RGB to YCbCr color space with two fire detection conditions being applied in this color space. Finally, the correlation coefficient is used to distinguish between fires and objects with fire-like colors. Our proposed algorithm is tested and evaluated on eleven fire and non-fire videos collected from the internet and achieves up to 95.87% and 97.89% of F-score and accuracy respectively in performance evaluation.

A Study on the Fire Risk Assessment : Based on the Proposal of a Fire Risk Assessment Processor Considering the Reality in Korea (화재위험도 평가에 대한 연구 : 국내 현실을 고려한 화재위험도 평가 프로세서 제안을 중심으로)

  • Lee, Jong Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • Recently, advanced countries assessment the risk of fire to prevent large-scale damage to high-rise buildings, In addition, performance-Based design, which is a fire risk assessment, is being conducted in Korea to prevent massive damage to high-rise buildings. However, unlike advanced countries, fire risk assessment in Korea is subject to fire risk assessment only for objects subject to consent from fire-fighting facilities such as building permits, When building engineers and fire-fighting engineers assessment the risk of fire, It has always been discussed because the results vary depending on which part of the evaluation is focused between economic feasibility and safety. Therefore, in this study, we would like to propose a fire risk assessment process suitable for domestic conditions by comparing the process of performance-based design, which is a domestic fire risk assessment, and the process of Iso/TC 16732 which is an overseas fire risk assessment.

Evacuation Safety Evaluation of High School according to Hydrogen Fluoride Leakage

  • Boohyun Baek;Sanghun Han;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.255-266
    • /
    • 2024
  • The purpose is to evaluate evacuation safety by simulating the toxic effects of hydrogen fluoride leaks in areas surrounding national industrial complexes and to suggest alternatives for areas that do not satisfy evacuation safety. For human casualties caused by hydrogen fluoride leakage accidents, Available Safe Egress Time (ASET) is calculated by the toxic effects quantified with the Areal Locations of Hazardous Atmospheres (ALOHA), an off-site consequence assessment program. The Required Safe Egress Time (RSET) is calculated through Pathfinder, an evacuation simulation program. Evacuation safety is assessed by comparing ASET and RSET. The ALOHA program was used to evaluate the time to reach AEGL-2 concentration in 12 scenarios. The Pathfinder program was used to assess the total evacuation time of the high school among specific fire-fighting objects. Of the 12 accident scenarios, ASET was larger than RSET in the worst-case scenarios 1 and 9. For the remaining 10 accident scenarios, the ASET is smaller than the RSET, so we found that evacuation safety is not guaranteed, and countermeasures are required. Since evacuation safety is not satisfactory, we proposed to set up an evacuation area equipped with positive pressure equipment and air respirators inside specific fire-fighting objects such as the high school.

Development of Video Work Manual for Rock-Drill Data In Fire Service (소방에서의 도상훈련 기초자료 영상화작업 매뉴얼 개발)

  • Cho, Jae-Kwan;Park, Hee-Jin;Hwang, Inn;Kwon, Hayrran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.103-128
    • /
    • 2002
  • As a result of trying the various manufacturing methods considering the reality of manpower and equipments with this manual, the following standardized procedures and contents can be suggested. (1) Since tools presenting Rock-Drill data must formalize the order of explanation although explainers are different, it will be valid that it is configured by existing power point method rather than by web document type. Composition of contents are selected on the basis of defence card and survey and then 8 items including initial screen, peripheral conditions, mobilization route, general conditions, use and structure by floor, department of vehicle consideration in activities and end screen are included. (2) Making methods and cautions of data included and used in power point are as follows ; - It was most effective that objects of fire fighting and location of neighboring fire fighting water were expressed by electronic map and drawing of inner building was made by scanning it after paining general architecture drawing(plan by each floor) rather than using drawing tools of EXCEL program or CAD drawing. And it was helpful to simplify contents of architecture drawing to wall, stairs and gate in understanding them. - Photographing of video data should be taken to show available fire fighting facilities in fire, use of planned space and the whole inner structure of each floor from the inside of fire fighting buildings and to display play time between 10 sec. and 1 min, for obstacles to distance from adjacent buildings or passage of special vehicles and fire fighting water from the outside of the building. - File format of video data taken in this way is most suitable to use wmv(window media video) or asf(advanced streaming format) type in consideration of time required for export, screen quality, file capacity and play type in Rock-Drill through network. - Still screen(photo) is more effective to express the department of fire fighting vehicles or other equipments than using video. (3) In configuration work of power point, hyper link was used most and configured to see any part at any situation like web document and then uniformity of presentation order of power point was complemented. (4) In case of sales facilities with the area of $35.557m^2$, the time of 22 hours and 30 minutes for five days was taken with five persons. Therefore, when eight-hour works a day were calculated, the whole process of video work for Rock-Drill can be finished with three day works.

  • PDF

Study on Space Organization Based on Significance Assessment of Interior Space Factors at 119 Safety Center (119 안전센터 실내공간요소 중요도 평가에 의한 공간구성연구)

  • Kim, Sung-Ju;Kim, Moon-Duk
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.257-266
    • /
    • 2014
  • This study has been performed to come up with any rational way for responding to the functions of fire-fighting spaces newly required by the changing social paradigms and to seek for the approach to designing fire-fighting spaces by taking into account the psychological and behavioral factors of fire-fighters who are exposed stress of operations. In particular, it is to satisfy any physical and functional requirements as special working-spaces and to reflect the psychological and behavioral approach to the workers who are forced to be at standby for a long time, which is the characteristic of their operation, to designing. Accordingly, for fundamental appreciation of whether or not such space programs as space organization needed for operational function are being practiced actively, the fire-fighting headquarters of Incheon City has been selected for the research. First, in the process of assessing the trend of organizing the space at safety centers for the recent 20 years, those built more than 20 years ago were left out from the space selection for the research. Second, those with less than 20 operators also were excluded. Third, among those completed in the same year, only one was selected, which was to avoid overlapping, with the consideration its regional representative nature for applying the safety centers in the jurisdiction of the headquarters equally. The study was performed through the visits to and the actual inspections by surveys at the selected 119 Safety Centers as well as the reviews of literature based on case studies. And for the assessment of significance, surveys and analysis of reliability and factors were carried out. The actual users of Safety Centers were picked as objects for the assessment of significance of space factors at 119 Safety Centers, which revealed that there are five types of dimensions for factor-analyzing standard with which users estimate any significance, which are "Area of Mobilization Preparation and Return" "Area of Standby" "Area of Working Activities" "Area of Employ Welfare" and "Area of Support".

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

A Study on Functionality Evaluation of Profit Model for Remodeling of Apartment House (공동주택 리모델링을 위한 수익모델의 기능성 평가 연구)

  • An, Min-Jae;Pyo, Jin-Myung;Kim, Eui-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.107-113
    • /
    • 2005
  • This study analyzes remaining repair rate and applied repair rate with the presentation of profit model for the purpose of pursuing maximization of added value through remodeling of apartment house. Objects of remodeling and item applying the whole replacement of functionality evaluation items include exterior of building (3 items maintaining the current conditions, 8 items requiring the whole replacement), water supply/sanitary/gas/ventilation facilities (6 items maintaining the current conditions, 6 items requiring the whole replacement, electric/fire fighting/elevator facilities (8 items maintaining the current conditions, 20 items requiring the whole replacement) and heating/water heater facilities (2 items requiring the whole replacement).