• Title/Summary/Keyword: Fire escape safety

Search Result 116, Processing Time 0.021 seconds

The Way for improvement of facility to strengthen accessibility of the site for fire department (소방대의 현장접근성 강화를 위한 설비의 개선방안)

  • Oh, Taek-Hum;Sung, Ja-Man;Pak, Chan-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

How Visual-Field Obstruction from Fire Smoke Influences a Resident's Necessary Time to Reach Fire Escape and Evacuation Route in a High-rise Apartment Housing (연기발생으로 인한 시야장애가 초고층 공동주택 거주자의 피난계단실 진입시간과 피난경로에 미치는 영향)

  • Seo, Sang-Mok;Choi, Jun-Ho;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • The purpose of this study is to know how visual-field obstruction from fire smoke influences a resident's necessary time to reach fire escape and evacuation movement in a high-rise apartment housing. Generally, fire smoke not only gives visual-field obstruction and breath troubles to residents but interrupts their evacuation behavior. If a fire smoke layer is formed in the core department when evacuee enters at the evacuation staircase until, residents will be made to undergo a range of vision obstacle. In order to set a situation like that, participants wore eye bandage which had been made especially before the experiment. Also as a comparative standard, through no.1442 Japanese construction ministry notices about the building evacuation safety verification method, this study calculated smoke layer's dissent time and evacuation time. Then to compare with the former, the participants without an eye bandage joined a experiment once again. This study has understood how fire smoke effects on one's evacuation delay by analyzing residents' evacuation time to reach the staircase and movement route, however, in this study a toxic gas is not considered because it might threaten participants not to breathe.

Performance Assessment Model for Fire Safety Protection of Office Building (사무소 건축물의 화재안전 성능 평가모델)

  • Yang, Eun-Bum;Hwang, Young-Sam;Lee, Chan-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.69-74
    • /
    • 2004
  • This study is to suggest a performance assessment model for fire safety protection of office building 34 asessment elements were chosen by interviewing with experts, reviewing several codes and existing relevant models, assessment elements included in this model are comprised of five categories which are 'performace of protected area', 'performance of fire partition', 'safety performance of fire escape', 'performace of smoke control system' and 'performace of fire fighting equipment'. The weight of each element was computed by systematic approach like an AHP (analytical hierarchy process), which was conducted by experts who work in the field of fire protection. This model would be utilized as a part of assessment model for the overall performace of domestic office building.

A Fundamental Research on the Safety Facilities of Railroad (철도 선로안전시설에 관한 기초연구)

  • Lee Seong-Won;Kim Seung-Hwan;Shin Seung-Kyo;Kim Tae-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.550-555
    • /
    • 2005
  • In this research, safety requirements for guard rail, buffer stop, car stop scotch block, protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are studied to establish a standard. First, various kinds of guard rails and their construction methods are investigated. Researches on the level difference of main track and guard rail, joint, length, and fastening force of guard rail are done. Second, the classification of buffer stop and car stop scotch block and its characteristics are examined, and the impact force, speed limit and capacity of buffer stop are summarized. Details of protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are also investigated. From this fundamental research results, basic data on the safety facilities of railroad system are established.

  • PDF

Proposal of safe fire escape system for the day-care center and the kindergarten (어린이집 및 유치원의 화재 대피용 안전 경로 시스템 제안)

  • Choi, Jun-Ho;Kwon, Mee-Rhan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.297-301
    • /
    • 2015
  • Day-care centers and kindergartens are increasing along with the damage caused by fire year after year. Infants and toddlers have a low response capability than adults to fire situations such as heavy smoke which causes less or zero visibility thus it is difficult in evacuation route during dangerous fire situations. Because of these circumstances, teachers need to build a safe pathway signage system along with the usual fire safety training needs of infants and children. In this paper, we propose a system for fire escape which marks the escape routes and are automatically implemented through the push function that smartphone recognizes during the real-time fire situation, and establish a system that verifies its authenticity.

A Study on the Ventilation Performance and Fire Characteristics with Different Types of Openings in External Wall of One Side Corridor Type Apartment (편복도형 아파트의 복도 외벽체 개구부 형태에 따른 환기성능 및 화재특성에 관한 연구)

  • Ko, Myeong Jin;Choi, Do Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The objective of this study is to verify the safety in case of fire and change of residential environment for different wall construction approaches in a stairways apartment house. In order to confirm that case_1, which is current case that most of wall is opened and the case 2, which upper part of wall is limitedly opened are compared and analyzed based on simulations of fire, escape and natural ventilation performance. The analysis reveals that possible escape time for case 1 was more than 600 seconds and for case 2 was 195 seconds. Since the escape times for both cases were over 128 seconds, it would be reasonable to assume that every resident would escape. The simulation results on natural ventilation performance shows the air change per hour of case 1 and case 2 were .19n/h and .16n/h and there was 1.2 times difference. However, the difference was too insignificant and it could be seen as that different approaches on wall construction would not significantly influence on natural ventilation performance.

A Study on the Development of Performance Based Fire Risk Assesment Program (FDS를 활용한 성능위주 화재위험성평가 프로그램개발에 관한 연구)

  • Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • `SOS', Simulator Of Safety assessment for fire, was developed to simulate fire safety assessment for a structure which is geometrically complex. The program(SOS) is intended to use for searching as well as designing tools to analyse the evacuation safety through a wide range of structure conditions. The computer program has a function which importing FDS's calculating results to each individual resident in the structure. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments individual speeds in accordance with the proximity of crowd members. This SOS program contributes to a computer package that evaluates the fire safety assessment of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

A Study on Human Behavioral Pattern and the Design of Escape Stair (인간행동습성과 피난계단의 설계에 관한 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.3-12
    • /
    • 1998
  • The purpose of this study is to examine that the escape stair of high-rise buildings has to be designed as a left-handed stair(a stair being designed to turn left whicle we go down the ground floor) judging from fire-safety point of view. Most of Korean people are right-handers. In case of right-handers it was found that the occupant's escape speed using a left-handed stair is more convenient and fast than of a right-handed stair(a stair being designed to turn right while we go down the ground floor). But most of the escape stair of high-rise buildings in Korea was designed as a right-handed stair. The fire code therefore should be provided that the escape stair of high-rise buildings should be a left-handed stair.

  • PDF

A study on the development of emergency management program for railway fire safety improvement (철도화재 안전개선대책수립을 위한 위기관리프로그램 개발 연구)

  • Wang, Jong-Bae;Kwak, Sang-Log;Hong, Seon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.235-240
    • /
    • 2003
  • In this paper, the fire safety management plan and the emergency action program for the railway safety improvement were reviewed. In the fire safety management plan, a series of preventive methods answering to such as a smoke exhaust installation, a fire warning device and a guide inducement will be come into preparation. Also, the damage reducing methods such as complement of fire safety equipments, establishment of refuge & escape system, consolidation of real-time control on fire response and operation procedure will be required for early repressing fire and minimizing fatality.

  • PDF

A Study on the Fire-Safety and Escape plan of Hotel Design (호텔건축의 화재안전과 피난계획에 관한 연구)

  • 김기만;박윤성
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 1988
  • Due to its commercial, ceremonial function, the hotel design has a tendency to be higher and larger, and its form being varied. But this tendency is not desirable in respect of architectural fire-safety. The higher its height and the larger its mass becomes, relatively the damage expectation becomes. Moreover, in case of fire, it is expected that many serious problems break out, because the users of a hotel, unlike those of office building or housing, are majority of unspecified people and they have no information about that building. Therefore, this study dealt with fire-safety problem in hotel design and tried to find out countermeasures of fire-safety and successful escafe against fire.

  • PDF