• 제목/요약/키워드: Fire casualties

검색결과 201건 처리시간 0.021초

급기가압 제연시스템의 현장 성능평가 연구 (Field Experiments on Performance Evaluation of Pressure Differential System for Smoke Management)

  • 김정엽;이동호;김하영
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.251-254
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The field experiments on two high buildings of 20 stories and 21 stories are carried out to evaluate the field performance of pressure differential systems for smoke management and the results of experiments are presented.

  • PDF

로지스틱회귀분석 모델을 활용한 화학사고 사상사고 예측모형 개발 연구 (A Study on Accident Prediction Models for Chemical Accidents Using the Logistic Regression Analysis Model)

  • 이태형;박춘화;박효현;곽대훈
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.72-79
    • /
    • 2019
  • 본 연구를 통해 화학사고 사상사고 예측모형을 개발하였다. 모형은 로지스틱회귀분석 모델을 활용하여 사상사고에 영향을 주는 변수를 도출하여 적용하였고, 통계적 검증방법과 오즈비를 활용하여 모형의 신뢰성 및 정확성을 검증하였다. 모형에 활용한 사고 자료는 과거 발생했던 화학사고 통계를 분석하여 활용하였으며, 사고의 유형, 원인, 발생 장소, 사상자 현황 및 사상자를 발생시킨 화학사고 등의 자료 분석을 통해 통계적으로 유의하게 나타난 독립변수(p < 0.05)를 적용하였다. 본 연구에서 개발한 모형은 사업장에서 화학사고로 인해 발생하는 사상사고의 예방 및 안전시스템 구축을 위한 연구로서 의의가 있다고 할 수 있다. 모형에 의한 분석결과 사상사고 발생에 가장 크게 영향을 미치는 변수는 폭발에 의한 화학사고인 것으로 조사되었다. 따라서 사업장에서 발생하는 폭발 유형의 화학사고를 예방하기 위한 대책마련이 시급하다고 판단된다.

The Effects of Activities and Working Conditions on Fire Accidents on Construction Sites

  • Yi, Kyoo-Jin
    • 한국건축시공학회지
    • /
    • 제20권4호
    • /
    • pp.383-389
    • /
    • 2020
  • Accidents on construction sites involving fires do not occur as often as accidents involving falls from height or collapses. However, once a fire accident occurs, there is a high risk of a large number of casualties. Fire on construction sites is affected by working conditions and the types of activities the construction workers are engaged in at the sites. This study aims to identify activities and working conditions at construction sites that are vulnerable to fire, and analyse how they correlate with each other and how they affect the causes and consequences of fire accidents at construction sties. I analysed 40 fire accident reports and listed the situations vulnerable to fire at construction sites considering direct causes, activities, and working conditions. The most dangerous combination of fire hazards can be the heating devices used during rest/sleep in the office/cabin/storage during cold weather. The next most hazardous combination can be sparks arising from painting, waterproofing, insulation, plumbing, or welding/melting work in an underground or confined space.

건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안 (Improvement of fire protection equipment the opening of according to narrow the distance between buildings)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

한·일 건축물 방화구획 기준 비교분석 (A Comparative Analysis on the building Fire Protection Standards of Korea and Japan)

  • 신영덕;한지우;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2019
  • Smoke and fire spread throughout the building as a result of problems in the fire prevention section of Uijeongbu Apartment Fire in 2015 and Jecheon Sports Center Fire in 2017 in Korea, causing a number of casualties. It is believed that the fire compartment standards need to be reviewed as the fire in recent buildings continues to show problems. In this study, a comparative analysis was conducted on the fire prevention zone standard with Japan to improve the fire compartmente standard in Korea.

  • PDF

초고층 건물의 재난 발생 시 작전전술 방안 (The Way of operations and tactics for Disaster plan of High-rise Buildings)

  • 이정일
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.

전산수치해석 기반 화재훈련 VR 시뮬레이터의 개발 (A Development of Fire Training Simulator Based on Computational Fluid Dynamics Simulation)

  • 차무현;이재경;박성환;최병일
    • 한국CDE학회논문집
    • /
    • 제14권4호
    • /
    • pp.271-280
    • /
    • 2009
  • An experience based training system concerning various fire situations which may result many casualties has been required to make rapid decision and improve the responsiveness. Recently, the necessity of virtual reality (VR) based training system which can replace a dangerous full-scale fire training and be easily adopted to the training or evaluation process is increasing. This study constructed tile virtual environment according to pre-defined scenarios, utilized the FDS(Fire Dynamics Simulator), three dimensional computational fire analysis program, to derive numerically simulated data on the propagation of fire. Finally, by visualizing the realistic fire and smoke behavior through virtual reality technique and implementing real-time interaction, we developed a VR-based fire training simulator. Also, in order to ensure the sense for tile real of a virtual world and reaI-time performance at the same time, we proposed appropriate data processing and space search algorithms, demonstrate d the value of proposed method through experiments.

화재안전을 위한 건축물 용도별 피난리스크 분석에 관한 연구 (A Study on the Analysis of Evacuation Risk by Building Application for Fire Safety)

  • 진승현;구인혁;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.164-165
    • /
    • 2021
  • In Korea, in the case of fire scenarios in performance design, it is assumed that the sprinkler is not working. In addition, it does not applicate various fire conditions. Therefore it is not enough that the accuracy about fire scenario. In foreign countries, reseach is being conducted to predict the casualities that can occur due to fire in the building space through statistical risk analysis. Also, research is consistently conducting for design that consider the sprinker probability of operation. Therefore, to analyze the fire risk of each building in Korea, the risk was analyzed using statistical data. As a result, the risk of casualties that can occur for each building use was analyzed as 0.6(persons/cases) for residential buildings, 0.25(persons/cases) for sales facilities, and 0.12(persons/cases) for buisiness facilities.

  • PDF

성장화재통계 기반 건축물 용도별 화재위험도에 관한 기초연구 (A Basic Study on the Fire Risk by Building Use based Growth Fire Statistics)

  • 서동구;이종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.218-219
    • /
    • 2020
  • The risk of a fire in a building is closely related to the usage of the building. In particular, all fires that occur in a building are not risky to safety of human life, and it is associated with the combustion area and the increase of total floor area of the building. Therefore, this study focused on safety of human life in terms of the statistics of fire with considering the aspect of growing fires and analyzed the statistical data of fire for 10 years. As for the analysis on fire, the time of occurrence by usages of buildings, frequency of occurrence and the ratio of casualties etc. were analyzed. It is expected that results of this study could be used for evaluations on a variety of parts in terms of design, construction and maintenance of buildings.

  • PDF

10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구 (The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility)

  • 류상훈;유용호;이동호
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.58-65
    • /
    • 2010
  • 최근 들어 발생하고 있는 화재 사고는 재산 피해 및 인명 피해 측면에서 점점 대형화 되어가고 있는 추세지만, 이를 효과적으로 예방하고 조치할 수 있는 종합적인 차원의 화재안전기술 개발을 필요로 한다. 특히, 초고층 빌딩이 우후죽순으로 들어서고 있는 지금, 새로운 패러다임의 진보된 화재안전기술의 필요성이 대두되고 있다. 따라서, 본 논문에서는 세 가지 종류의 산소소모법 칼로리미터인 bench scale calorimeter(cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter(Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter(Industry calorimeter/Avg. 10MW)에 의한 열방출율 측정과 이때 발생된 연기발생량과의 상관관계를 찾고자 한다. 이렇게 찾아진 열방출율과 연기발생량과의 상관관계를 활용하여 새로운 개념의 연기감지기를 개발하여 화재 사고 시 인명피해 및 재산피해를 최소화 하고 궁극적으로 이러한 이론을 바탕으로 초고층화 되고 있는 건축물에 새로운 개념의 화재경보 및 피난 시스템의 개발 및 적용이 가능하리라 예상된다.