• Title/Summary/Keyword: Fire administrator

Search Result 18, Processing Time 0.022 seconds

A Study about Research on the Actual Condition for Fire Counterplan of Main Temple Wooden Cultural Properties (중요사찰목조문화재의 소방대책을 고려한 실태조사에 관한 연구)

  • Back, Min-Ho;Shin, Ho-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.121-130
    • /
    • 2009
  • This study is researched about the field trip of temples and the data for fire extinguishment manual of fire stations: it is done from June 2008 to December 2008 the 80 main temple wooden cultural properties among the 124 main wooden cultural properties appointed by the Cultural Heritage Administration. Cultural properties appointment classification, location classification, temple area, building area in a temple, building area of appointment cultural properties, a fire engine drive direction for fire suppression in a fire, distance from a fire station, and present condition of a fire administrator are researched. The cultural properties possess characteristic is in 2 cases: the whole things in a temple are appointed as cultural properties and only the wooden building is. The cultural properties are classified: the transport is possible or not. The special quality of cultural properties are classified for early correspondence and cultural properties transport in a fire and the basic data are arranged for damage limitation.

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

The Study for Fire Prevention of Main Wooden Cultural Properties of Korea (국가지정 목조문화재의 소방대책에 관한 실태조사)

  • Back, Min-Ho;Lee, Ji-Hyang
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is searched in the on actual condition and analysis about the fire fighting measure of 123 main wooden cultural properties designated by the Cultural Heritage Administration. First, the management of wooden cultural properties and the present condition of fire occurrence are arranged. Second, The field research and the information research of related government agencies are done from August. 2008 to October. 2008 about 123 main wooden cultural properties: Cultural properties designation classification, location classification, building area, number of possession cultural properties, present condition of fire fighting, a fire engine drive direction for fire suppression, number of self-defense fire brigade, fire administrator nomination, and the distance and time from a fire station are arranged in this study. Third, the inside and outside present conditions are classified and analyzed by average index for the fire occurrence risk of 123 main wooden cultural properties. And the basic data is arranged for the fire fighting measure of main wooden cultural properties.

A Study on Introduction of Student Volunteer Fire Department in Dormitory far from Fire Station (근접성이 불리한 대학 기숙사의 학생 의용소방대 도입에 관한 연구)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.65-69
    • /
    • 2015
  • The university dormitory have various functions and large floating population so in the occurrence of fire, there could be heavy casualties. Also, when university dormitory is located far from fire station, it is difficult to fire brigade arrives on Golden Time. Therefore, university dormitory need response capabilities for fire by itself. This study conducted a simulation experiment on those residing in K University dormitory in Gangwon-do, where site proximity is unfavorable, to observe evacuation characteristics of the occupants. As a result, evacuation is delayed due to a lack of evacuation routes and administrator, some students lack of fire awareness. Also fire brigade didn't arrive on Golden Time. Therefore, to resolve problems it is proposed that a student fire volunteer department.

MULTI-SENSOR INTEGRATION SYSTEM FOR FOREST FIRE PREVENTION

  • Kim Eun Hee;Chi Jeong Hee;Shon Ho Sun;Jung Doo Young;Lee Chung Ho;Ryu Keun Ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.450-453
    • /
    • 2005
  • A forest fire occurs mainly as natural factor such as wind, temperature or human factor such as light. Recently, the most of forest fire prevention is prediction or prevision against forest fire by using remote sensing technology. However in order to forest fire prevention, the remote sensing has many limitations such as high cost and advanced technologies and so on. Therefore, we need to multisensor integration system that utilize not only remote sensing but also in-situ sensing in order to reduce large damage of forest fire though analysis of happen cause and prediction routing of occurred forest fire. In this paper we propose a multisensor integration system that offers prediction information of factors and route of forest fire by integrates collected data from remote sensor and in-situ sensor for forest fire prevention. The proposed system is based on wireless sensor network for collect observed data from various sensors. The proposed system not only offers great quality information because firstly, raw data level fuse different format of collected data from remote and in-situ sensor but also accomplish information level fusion based on result of first stage. Offered information from our system can help early prevention of factor and early prevision against occurred forest fire which transfer to SMS service or alert service into monitoring interface of administrator.

  • PDF

A School Network Construction using the ESM System (ESM 시스템을 이용한 안정된 학내망 구축)

  • Lee, Dae-Sik;Yun, Dong-Sic;Ahn, Heui-Hak
    • Convergence Security Journal
    • /
    • v.5 no.3
    • /
    • pp.1-7
    • /
    • 2005
  • Today, network is a fragile state in many threat attacks. Especially, the company serviced like internet or e-commerce is exposed to danger and targeted of attacker Therefore, it is realistic that the company use the security solution. It exist various security solution in our school network. For example, Firewall, IDS, VirusWall, VPN, etc. The administrator must manage various security solution. But it is inefficient. Therefore, we need the Management System to controll every security solution. In this paper, we deal with basic contents of security solution to manage the ESM and merits and demerits when use it. Also we suggest method that the Administrator can manage his network more efficiently and systematically by using the ESM in our school network.

  • PDF

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

Study on the Factors Influencing School Administrators' Safety Education Satisfaction on Transition Intention: Focusing on the Mediation Effect of School Safety Awareness (학교관리자 안전교육의 만족도가 전이의도에 미치는 영향요인 연구 - 학교안전 인식의 매개효과 분석을 중심으로 -)

  • Chae, Jin
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.152-162
    • /
    • 2019
  • This paper proposes improvement measures of a school safety education program by analyzing the factors affecting the cognition of school safety on the school safety transfer intention and their mediating effects. In summary, the satisfaction with the contents was represented as a variable with the greatest influence on the transfer intention followed in order by satisfaction with the instructor and satisfaction with the environment. On the other hand, satisfaction with the teaching method was not significant. In addition, the general cognition on school safety education showed that it has mediating effects on the relationship between the satisfaction with the school administrator safety education and the school safety transfer intention.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

Real-time Reagent Management System Using NFC / Sensor (NFC/센서를 이용한 실시간 시약 관리 시스템)

  • Kim, Ho-Sung;Jang, Jae-Myung;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.421-426
    • /
    • 2016
  • Recent developments in internet technologies has enabled widespread growth of embedded systems like Arduino, Raspberry Pi and other smart home systems. A research in the industrial sector on the utilization of the board has been made. The development needs of the embedded board in a reagent bottle case system has been highlighted. Current reagent Management System has to hold and manage the reagent itself is mostly to save the program using handwritten or machine. In addition, there is a risk to the system during the vulnerable zone administrator to manage the situation of the reagent bottle case can lead to a massive fire. In this paper, reagent bottle case RFID readers and data in real-time is monitored by attaching a sensor management through the database and sends a warning message to the mobile device of the administrator in real time during hazardous situations in the reagent bottle case. This is improve the reliability and efficiency of reagent bottle case.