• Title/Summary/Keyword: Fire Equipment

Search Result 672, Processing Time 0.023 seconds

Influence on the Satisfaction of Fire Fighting Equipment by Distribution of Fire Fighting Equipment: Focusing on Mediating Effect of Reliability of Fire Fighting Equipment (소방공무원들이 인지하는 소방장비 보급으로 소방장비 만족도에 미치는 영향: 소방장비 신뢰성의 매개효과를 중심으로)

  • Lee, Sun-Beom;Kim, Yang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.8
    • /
    • pp.677-684
    • /
    • 2017
  • This study verifies effects of the distribution of fire fighting equipment on the satisfaction of fire fight equipment among fire officers and the mediating effect of the reliability of fire fighting equipment on the relationship between the two variables in order to provide preliminary data on the development of fire fighting equipments. Fire officers from the seven fire stations located in Gyeonggi-do province were selected and surveyed to achieve the purposes of the study. Using AMOS 18.0, structural equation modeling were applied to analyze the data. Major findings are as follows. First, the propriety of the amount of distribution of fire fighting equipment and the timeliness of distribution have positive effects on the reliability of fire fighting equipment. Second, the reliability of fire fighting equipment has a positive effect on the satisfaction of fire fighting equipment. Third, the propriety of the amount of distribution of fire fighting equipment has a positive effect on the satisfaction of fire fighting equipment. It was found that the reliability of fire fighting equipment has a partial mediating effect on the relationship between the propriety of the amount of distribution of fire fighting equipment and the satisfaction of fire fighting equipment.

Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology (감지기의 점검 기술향상을 위한 복합시험기의 개발)

  • Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Bookstore - (건축물의 적재가연물 특성에 관한 연구 -대형서점의 적재가연물 연소발열성상-)

  • Nam, Dong-Gun;Yuji, Hasemi;Jung, Jong-Jin;Lim, Woo-Sub;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.3-6
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book.

  • PDF

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

The Study on Effective Maintenance and Management of the Fire Fighting Equipment (소방장비의 효과적 운용방안에 관한 연구)

  • Chae, Jin;Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.48-60
    • /
    • 2009
  • The field of fire administration has been reinforced and intensified with the manpower and all sorts of equipment, but since the consequence that was mainly given undue value to the quantitative expansion, some problems in the aspect of maintenance and management have been emerged. Characteristically, though, fire equipment should be highly practical, economically efficient and durable, and also have the effectiveness of utilizing them to the right place, maintaining and managing are not as appropriate as they need to have. Therefore, the research provide the effective measures of operating fire equipment by making a comparative study of problems drawn by the analysis of actual conditions on the maintenance and the management of fire equipment.

A Study on Measuring of Fire Extinguishing Concentration for Organic Material Using Novec (노벡을 이용한 유기물의 소화농도 측정에 관한 연구)

  • Lim, Woo-Sub;SaKong, Seong-Ho;Jung, Jong-Jin;Nam, Dong-Gun;Choi, Kenu-Joo;An, Sang-Su;Kim, Jong-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.456-460
    • /
    • 2008
  • This study was on basic step to develop a good clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using Novec which is inert gas. In study used to Cup Burner Test its made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test. The finding is that a new clean agent, Novec has a very efficient extinguishing ability in a state of gas.

  • PDF

Subjective Responses for the Fire Signal Sound of Acoustic Reporting Equipment Depending on Visual Information (시각정보 변화에 따른 음향통보장치 신호음의 청감반응)

  • Song, Hyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.313-319
    • /
    • 2005
  • Instruction and prevention of the safety for a fire have been performed continuously by nation. However, the accident due to a fire is not decreasing and causes a serious calamity to people. It is at the initial stage of fire burning that the most effective way to reduce damage is to evacuate and fight a fire. When a fire burns, the equipments reporting to other person or organization concerned are called 'acoustic reporting equipment'. Among those equipments reporting to person, 'a fire bell' is the easiest equipment to approach. Observing the behaviors of people when a fire burning, some are in a quiet indoor, some in a room with other people, some in a square with many people and some in indoor filled with smoke etc. This study aims to find out an acoustic reporting signal appropriate for visual information. For the experiments, visual-auditory experiments were performed through reporting signals and visual informations with several situations that is able to be faced at when a fire burns.

The study of Connection Emergency lantern with Fire Alarm System (자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구)

  • Chun, Jung-Ham;Lee, Sang-Hwa;Kwon, Oh-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

A Study on the Firefighting Equipment in Petrochemical Plants (석유화학공장의 소화설비에 관한 연구)

  • Kim, Bong-Hoon;Choi, Jae-Wook;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.14-22
    • /
    • 2014
  • Hydrocarbon fires and explosions in petrochemical plants have occurred repeatedly every year. But domestic law of fire protection system is insufficient for the worst case scenario. In this study, we analyzed domestic and foreign standards of fire protection system in petrochemical plants and surveyed firefighting equipment of 32 petrochemical plants in ulsan petrochemical complex. Finally, it is necessary to design fire water supply based on the worst case scenario in petrochemical plants and firefighting equipment such as fixed water spray system, elevated monitor nozzle, water curtain, large amount foam monitor system should be installed for the worst case scenario in petrochemical plants.