• Title/Summary/Keyword: Fire Emergency.

Search Result 951, Processing Time 0.027 seconds

Design of Emergency Fire Fighting and Inspection Robot Riding on Highway Guardrail

  • Ma, Xiaotong;Li, Xiaochen;Liu, Yanqiu;Tao, Xueheng
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.6
    • /
    • pp.833-843
    • /
    • 2022
  • Based on the problems of untimely Expressway fire rescue and backward traditional fire rescue methods, an emergency fire fighting and inspection robot riding on expressway guardrail is designed. The overall mechanical structure design of emergency fire fighting and inspection robot riding on expressway guardrail is completed by using three-dimensional design software. The target fire detection is realized by using the target detection algorithm of Yolov5; By selecting a variety of sensors and using the control method of multi algorithm fusion, the basic function of robot on duty early warning is realized, and it has the ability of intelligent fire extinguishing. The BMS battery charging and discharging system is used to detect the real-time power of the robot. The design of the expressway emergency fire fighting and inspection robot provides a new technical means for the development of emergency fire fighting equipment, and improves the reliability and efficiency of expressway emergency fire fighting.

A Study on the Activation·Specification of 119 Rescue & Care in JeJu (제주도 119구조·구급대의 활성화 및 전문화 방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik;Lee, Young-A
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.153-168
    • /
    • 2002
  • Since 1992, conventional fire fighting businesses have been converted into a metropolitan autonomous fire fighting system to be ready for a variety of disasters. However, the corresponding investment has been overlapped due to the non-integration of businesses to prevent any potential disasters, and a series of collaborative systems have been not functioning so well. In the meantime, our fire fighting sector has been trying to set up its own clean and faithful position by abolishing any inconvenient system or outsourcing private sectors, and expanded its work scope from conventional fire fighting even to rescue and emergency works. While focusing on handling disaster, the fire fighting sector has been widely trusted and reliable throughtout our nation. Moreover, our fire fighting sector has secured nation wide mobile organizations, technical personnel by field, special equipments and independent communication network. In addition, the fire fighting sector has knowledges, expertise and capabilities required for managing disasters, while in charge of almost every disaster management works including fire, explosion, collapse, disaster and flood. It becomes an organization for comprehensive disaster management under an absolute national trust, which is based on the system for prevention, preparation and countermeasure against a variety of disasters. Thus, our fire fighting sector must make many efforts and try to modernize conventional education and training. The ways to facilitate rescue and emergency works may include the nurture of technical fire fighting personnel along with modernized equipments, the reinforcement of rescue and emergency education, the facilitation of operating civil defense corps, the facilitation of operating volunteer fire fighting corps, the better arrangement of 119 briefing room for public healthcare in provincial offices, the sterilization of rescue instruments and equipments the better repair education for emergency rescue member, the establishment of regional emergency assistant system and the expansion of fire fighting personnel and equipments. In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations: Building up security system along with operational expansion, building up a system for emergency medical treatment, building up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119 we can review the following considerations : Improving the education for fire fighting training corps under Jeju Provincial Fire and Disaster Management Department, providing rescue members with more opportunities for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. If these requirements are met, it is expected that the fire fighting departments in Jeju province can cope with every accident and disaster a little more rapidly and quickly in compliance with local needs, so that they can keep their own position as a public fire fighting organization which may be trusted by the public.

  • PDF

The study of Connection Emergency lantern with Fire Alarm System (자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구)

  • Chun, Jung-Ham;Lee, Sang-Hwa;Kwon, Oh-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

Concept Design of Fire Safety Module for SV20 Service in the Korean e-Navigation System

  • Kim, Byeol;Moon, Serng-Bae;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.42 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • The Korean e-Navigation system is a Korean approach to correspond with implementation of IMO e-Navigation. It provides five services, among them SV20 service, a ship remote monitoring system that collects and processes sensor information related to fire, navigation, and seakeeping performance safety. The system also detects abnormal conditions such as fires, capsizing, sinking, navigation equipment failure during navigation, and calculates the safety index and determines the emergency level. According to emergency level, it provides appropriate emergency response guidance for the onboard operator. The fire safety module is composed of three sub-modules; each module is the safety index sub-module, the emergency level determination sub-module and emergency response guidance sub-module. In this study, operational concept of the fire safety module in SV20 service is explained, and fire safety assessment factors are estimated, to calculate the fire safety index. Fire assessment factors included 'Fire detector position factor,' 'Smoke diffusion rate factor,' and 'Fire-fighting facilities factor.'

A Study on the Analysis and Improvement methods of Emergency Medical Service Systems for Large Scaled Fire (대형화재에 대비한 응급의료체계에 관한 분석과 개선방안)

  • Lee, Maria
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.1
    • /
    • pp.41-52
    • /
    • 2007
  • In Korea, Crowds, as well as more complex and larger structures, have been caused more victims in the event of fire. In that situation, EMSS should have done triage the patients according to their severity in the field, treat with standard guidelines as like advanced burn life support and transfer to appropriate facility. But in many cases, they didn't practice like that. The purpose of this study is to give basic data for proper emergency medical services by analysing EMSS of large scaled fire in Korea and suggesting some improvement methods. The improvment methods are like this ; First, developing of protocols about burn patient is needed for EMT and dispatcher. Second, Legal approval for advanced treatment is needed for EMT. Third, Fire-helicoptors are needed in Daejeon and Jeju. And Emergency Medical Helicoptors are needed in EMSS. Forth, more advanced emergency medical centers of burn must be established. Sixth, more pocket-mask and burn sheet are needed for 119 rescuer. Finally, building owners must change inflammable materials as non-inflammable materials and educate fire-prevention and first-aid to employees.

  • PDF

A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP) (소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.29-34
    • /
    • 2012
  • The purpose of this study is to propose an effective operating method of a power generator used by the Emergency Power System in case of a simultaneous fire and of the limitations of the interlock system the power supply from the emergency power generator. On the Emergency Power System with Reserved Fire-fighting Power (RFP), in case of an overload, the collective control Emergency Power System signals the main circuit breaker to shut off the supply to the emergency load, leaving the supply to the firefighting load uninterrupted to the end. The sequential control Emergency Power System signals the firefighting power supply to shut off the fire stage of the emergency load and continues to monitor the power supply. If an overload happens again from increased firefighting load, the sequential control Emergency Power System sends a secondary signal to shut down the second stage of the emergency load.

A study on job satisfaction and the turnover intention of fire fighters (소방공무원들의 직무만족과 이직의도에 관한 연구)

  • Kim, Hong-Jo;Baek, Hong-Seok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.18 no.1
    • /
    • pp.95-106
    • /
    • 2014
  • Purpose : This study was attempted to check the correlation between job satisfaction and turnover intention and to provide the basic information to increase job satisfaction of fire fighters. Methods : A total of 369 questionnaires were distributed and 354 questionnaires were filled out and collected for analysis. Results : There was difference in turnover intention by general characteristics. According to position, group of Fire lieutenant or more is lower than that of Fire sergeant or less (F=3.61, p=.014). The group of rescue & emergency service and administration was significantly lower than other groups(F=4.84, p=.001). In pattern of duties, day service group was significantly lower than shift work group in .05 level(t=2.59, p=.022). Finally, in the correlation, the more job satisfaction increase, the more turnover intention decrease that represents inverse correlation between job satisfaction and turnover intention(r=-.523, p <.001). Namely, it represents the results that the higher job satisfaction is low turnover intention. Conclusion : More studies of fire officer in other cities are required to generalize the results. We have to develop program for job satisfaction for fire officer firstly, because program for job satisfaction used in this study was not developed for fire fighters.

A Study on Influential Factors of Egress Behavior in Respect of the Fire Prevention Manager in the Large-scale Shopping Mall (대규모 판매시설의 방화관리자의 측면에서 본 피난행동 영향요인에 대한 연구)

  • 박재성;윤명오
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.108-113
    • /
    • 2004
  • Emergency response of fire prevention manager has an effect on decisive emergency exit behavior of customer who is not accustomed to emergency response in a large-scale shopping department on fire. Especially enclosed stairways in a large scale store are usually located in back space where is impossible for customer to access. Therefore, speedy emergency exit inducement by fire prevention manager is needed for the customer's safe egress. The object of study is to analyse the factors affecting egress behavior and emergency response of fire prevention manager in respect of fire prevention management.

The Level of Awareness and Practice in Prehospital Emergency Patient Assessment and Emergency Care of Paramedic in Fire Station (1급 응급구조사의 병원 전 응급환자평가와 응급처치시행에 대한 인식과 실천정도)

  • Kang, Yong-Ju;Choi, En-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.2
    • /
    • pp.67-84
    • /
    • 2011
  • Purpose: The aim of this study is to present the basic data for qualitative improvement of emergency care for emergency patient by paramedic in fire station by understanding the level of awareness and practice in prehospital and transfer step, and understanding the level of emergency care and improvement of clinical knowledge through hospital clinical training. Methods: The researchers explained the objective for 143 persons who completed hospital clinical training from June 2nd, 2006 to October 23rd, 2009 among paramedic in fire station. The questionnaire in this research consisted of 80 questions. In the reliability for the awareness of emergency patient assessment, cronbach's $\alpha$ was 0.95, and in the reliability for emergency care fulfillment, cronbach's $\alpha$ was 0.93. reliability for clinical knowledge improvement is cronbach's $\alpha=.95$, and reliability for emergency care fulfillment is cronbach's $\alpha=.82$. Collected data was analyzed through SPSS 18.0 statistics program for frequency, percentage, average, standard deviation, Paired t-test, t-test, Correlation Coefficient, and internal consistency reliability was analyzed by cronbach's $\alpha$. Results: 1) The paramedic awareness and practice difference for emergency patient is statistically signification for general patient assessment(t=14.159, p=.000), trauma patient assessment(t=11.288, p=.000), internal medicine patient assessment(t=10.898, p=.000), and it shows the level of practice is lower than the level of awareness. 2) The paramedic difference between the level of awareness and practice according to whether or not they have clinical career is not signification on awareness(t=3.119, p=.125), and is high on practice(t=3.119, p=.002). 3) The correlation between paramedic awareness and the level of practice shows positive correlation(r=.61, p=.000). The higher the awareness of emergency patient assessment is, the higher the level of practice is. 4) The difference between paramedic clinical knowledge improvement and the level of emergency care practice is statistically significant(t=3.351, p=.001). 5) 89.6%(128 persons) of paramedic replied hospital clinical training experiences are helpful for field activity. 92.3%(133 persons) replied they apply well for clinical knowledge learned during hospital clinical training and emergency care skills in the field. Conclusion: Paramedic in fire station must evaluate the patient's initial assessment and activate the transfer system to the emergency department. It is necessary to develop and implement the effective education program continuously. The education program should systemize currently operated hospital clinical training. emergency disease and symptoms emergency care method, and practice mainly skill education should be progressed. In the prehospital and transfer management, high quality of medical assessment is required to the emergency medical service system. Medical direction from the doctors can feedback the paramedic continuously and continuing education must be provided to the paramedic in fire station.

The 2018 Fire department emergency medical technician survey (2018년 소방공무원 응급구조사 총조사)

  • Yun, Hyeongwan;Park, Jooho;Lee, Hyeongyeong;Han, Seungtae;Lee, Jeamin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.145-162
    • /
    • 2021
  • Purpose: The 2018 General survey of emergency assistance was conducted to examine the working conditions and welfare, including educational direction, interests, and awareness of work, of the fire department emergency medical technicians (EMT). This would be used as basic data for future policy directions. Methods: Among the fire-fighting officers in 16 cities nationwide, emergency rescue workers engaged in first-aid activities were targeted. With prior consent, a survey was conducted through electronic documents. Of the total 1,227 people, responses from 1,151 were finally analyzed, excluding 76 who did not respond appropriately. Results: The working conditions and welfare of 119 firefighters were moderate, but in the fields of education and interest, the learning according to the regulations was high. In particular, satisfaction with the scope of work was found to be below average. However, it was positive that it will play a role as a social safety net in the future and will converge with cutting-edge science. Conclusion: Although this study was a total investigation of the EMT survey, conducting an EMT survey on all fire fighters in Korea is difficult. Further research is needed, particularly on first-class emergency medical personnel who play a major role in 119 paramedics.