• 제목/요약/키워드: Fin-and-Tube Heat Exchanger

검색결과 264건 처리시간 0.026초

확대모델을 이용한 특성화된 핀형상의 열전달평가 (An Evaluation of Heat Transfer Characteristics of Individualized Fin Type Using Large Scale Model)

  • 윤점열;강희찬;이관수;김무환
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.166-175
    • /
    • 1996
  • In recent years, air-conditioning units designed with higher efficiency and more compactness are required due to emphasis on energy efficiency in home electrical appliances. This trend in the air-conditioning industries has accelerated the development of improved heat exchanger with a better performance in heat transfer aspects. In this study, experiments were performed to investigate the shape and configuration of fins affecting on the performance of the conventional fin-and-tube type heat exchanger equipped in a commercial air conditioners. The geometry similtude method was employed to measure the heat transfer coefficient and pressure drop. Experimental results show that this method is very useful to analyze the heat transfer characteristics of the fin-and-tube type heat exchanger. It is also found that the slit fin has better performance than the conventional fin type in the air conditioners. The present results indicate that heat transfer from the fin si influenced by the parameters such as the forming area of the slit fin, the type of interrupted surfaces like a louver or slit, slit patterns and slit raised direction, and it also affects the overall heat exchanger performance.

  • PDF

관 형태에 따른 Shell and Tube 열교환기의 열전달계수 관한 연구 (Study on Heat Transfer Coefficient Test of Evaporator Tube in Shell and Tube Heat Exchanger by Shape)

  • 김재정;박재홍;김인관;김영수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1107-1112
    • /
    • 2006
  • The purpose of this study is a heat transfer coefficient test of evaporator tube in shell and tube heat exchanger by shapes, using R-404A. The experimental apparatus is designed to simulate the real heat transfer rate in one shell and tube heat exchanger. The test section is formed four type tubes that are Inner ridged tube, Corrugated tube, Turbo-C tube, Inner fin tube and shell type is formed by electrical heater. All tests were performed at a fixed refrigerant evaporator temperature at $1.5^{\circ}C,\;-3^{\circ}C$ and with mass fluxes of 29, 25 kg/hr. Heat transfer rate is calculated a enthalpy difference in test section. In experiment, heat transfer coefficient measured one by one and electrical heaters are supplemented by evaporator.

  • PDF

V형 원형휜-원형관의 강제대류 열유동 특성 (Forced Convection Characteristics of V type Circular-finned Tube Heat Exchanger)

  • 이종휘;임무기;강희찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1348-1354
    • /
    • 2009
  • The purpose of the present study is to investigate the flow resistance and the heat transfer characteristics of V type circular fin-tube heat exchanger. Four kinds of V type fin having the same fin area and the different span wise angle tested numerically. Test data for the heat transfer, pressure drop and fin temperature were shown and discussed. The pressure drop and heat transfer increased for decreasing the span wise angle up to 58% and 25% respectively.

  • PDF

루버형 휜을 가진 휜관형 열교환기의 착상현상 연구 (Study on the Frosting Phenomenon of the Fin and Tube Heat Exchanger with a Louvered Fin)

  • 김정국;코야마 시게루;쿠와하라 켄;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제11권4호
    • /
    • pp.157-163
    • /
    • 2008
  • The present study investigated the pressure drop and the total frost mass of the louvered fin type heat exchanger, which is widely used at the air-conditioning system. The pressure drop due to the frosting phenomenon and the total frost mass were investigated by changing the wet bulb temperature condition of the inlet air. Hence the brain of 55wt% was used as a cooling solution instead of a common refrigerant. The temperature difference between the brine and the tube outside wall at the outlet of heat exchanger was $10^{\circ}C$, at maximum, higher than that at the inlet of heat exchanger. As the wet bulb temperatures were increased, the pressure drop was linearly increased due to the increment of frost mass. And the increment of heat exchange rate was smaller than that of inlet air enthalpy due to the increment of frost mass. The pressure drop of air side was rapidly increased due to the progress of frosting phenomena. The run time that the pressure drop occurred rapidly was decreased by the growth of frost.

  • PDF

Measurement of the Thermal Characteristics of Finned-tube Heat Exchanger Fin by Using the Liquid Crystal Technique

  • Kang, Hie-Chan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.28-35
    • /
    • 2001
  • This study deals with the thermal characteristics of finned-tube heat exchanger having two rows used in the air-conditioning application. Pressure drop and heat transfer coefficient were measured by using the three times models of plain fin and compared with the theory. Also the temperature distribution and heat conduction in the fin was measured by using the liquid crystal method. The surface temperature of rear row was nearly constant, and heat conduction in the fin was stronger near the front row than the rear row.

  • PDF

착상조건 하에서 핀-관 열교환기의 성능예측을 위한 컴퓨터 시뮬레이션 (A Computer Simulation for Performance Prediction of Fin-Tube Heat Exchanger under Frosting Conditions)

  • 이관수;박희용;이욱용;이태희;이수엽;이명렬
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.161-170
    • /
    • 1995
  • This study is concerned with the numerical analysis of performance on fin-tube heat exchanger under frosting condition. In this work, tube-by-tube method using LMED is employed. The present results are compared with O'Neal's experimental and numerical results. A standard evaporator model with 2rows-2columns is selected to investigate the effects of the various parameters such as fin pitch, air flow velocity, and humidity. The results show that frost thickness and the amount of frost per unit area decrease as fin-pitch becomes narrower. In the meantime, frost thickness and accumulation rate increase with higher inlet air humidity. It is shown that heat transfer rate increases during 30minutes and then it decreases. Heat transfer rate and the amount of frost increase with air velocity, however frost thickness does not increase over a certain velocity.

  • PDF

PF 열교환기를 적용한 공조기의 성능 비교 실험연구 (Experimental Study on Performance Comparison of Air-Conditioner with PF Heat Exchanger)

  • 권영철;박윤창
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.470-475
    • /
    • 2009
  • 본 연구에서는 핀-관 열교환기와 PF 열교환기의 열전달 특성과 이를 적용한 공조기의 성능을 비교 조사하였다. 또한 공조기의 냉방기간 에너지효율(CSPF)을 평가하였다. 열교환기 실험을 위해 3종류의 열교환기에 대한 열전달 및 압력강하를 그리고 공조기 성능평가를 위해 냉방표준, 냉방저온에서 냉방능력, 소비전력, COP를 산출하였다. 실험은 칼로리미터와 항온수조를 사용하여 수행되었다. 유입공기 속도가 증가함에 따라 열교환기의 열전달율과 압력강하는 증가하였다. PF 열교환기 적용 시스템의 적정 냉매량은 핀-관공조기보다 약 $15{\sim}20%$ 감소하였으나, 냉방능력은 증가, 소비전력은 감소하여 COP는 향상되었다. 사각형 핀을 가진 PF 열교환기가 삼각형 핀보다 냉방능력과 COP가 더 우수하였다. 실환경 온도조건을 반영하기 위해 PF 열교환기와 핀-관 열교환기 적용 시스템의 CSPF가 계산되었다.

Effect of Zinc Addition in Filler Metal on Sacrificial Anode Cathodic Protection of Fin-Tube Aluminum Heat Exchanger

  • Yoon-Sik So;Eun-Ha Park;Jung-Gu Kim
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.349-360
    • /
    • 2023
  • This study investigated the tri-metallic galvanic coupling of different metals in the tubes, fillers, and fins of a heat exchanger. The goal was to prevent corrosion of the tubes using the fin as a sacrificial anode while ensuring that the filler metal has a more noble potential than the fin, to avoid detachment. The metals were arranged in descending order of corrosion potential, with the noblest potential assigned to the tube, followed by the filler metal and the fin. To address a reduction in protection current of the fin, the filler metal was modified by adding Zn to decrease its corrosion potential. However, increasing the Zn content of filler metal also increases its corrosion current. The study examined three different filler metals, considering their corrosion potential, and kinetics. The results suggest that a filler metal with 1.5 wt.% Zn addition is optimal for providing cathodic protection to the tube while reducing the reaction rate of the sacrificial anode.

단일 핀-관 열교환기에서 엔트로피 생성에 관한 연구 (A Study on the Entropy Generation of Single Fin-Tube Heat Exchanger)

  • 박희용;이관수;김병규
    • 태양에너지
    • /
    • 제10권1호
    • /
    • pp.14-21
    • /
    • 1990
  • 단일 핀-관열교환기와 관련된 열역학적 최적설계법을 기준하여 핀-관열교환기의 엔트로피 생성율을 조사하였다. 엔트로피 생성율(비가역성)해석법을 사용하여 최적설계조건을 구하였고 설계조건의 변화에 따른 총엔트로피 생성율과 핀의 길이, 관의 안지름과 바깥지름 및 핀간거리를 조사하였다. 이 연구의 결과에 따르면 바깥지름이 클수록 최적핀간거리와 핀높이는 커지고 엔트로피 생성율과 최적안지름은 작아진다. 또한 핀 두께를 증가시키면 계의 엔트로피 생성율과 최적핀간거리는 증가하고 핀높이를 증가시키면 엔트로피 생성율과 최적바깥지름은 증가한다.

  • PDF

The Development of Catalytic Combustor With Heat Exchanger

  • Phil, Yu-Sang;Seok, Seo-Yong;Seop, Song-Kwang
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.21-27
    • /
    • 2002
  • Catalytic combustor with heat exchangers are often employed in process technology where a compact design is required [1]. The use of fin and tube heat exchanger offers the enhanced surface area for heat exchange. The recent progress and performance of the fin-tube heat exchanger, especially airside, has been reviewed extensively by Wang[2].(Omitted)

  • PDF