• Title/Summary/Keyword: Field heat

Search Result 2,036, Processing Time 0.027 seconds

Changes in Quality of PEF Treated Apple Juice during Storage (고전압 펄스 전기장 처리된 사과주스의 저장중 품질변화)

  • Kim, Kyung-Tack;Kim, Sung-Soo;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.375-379
    • /
    • 1999
  • This study was designed to develop non-thermal pasteurized fresh apple juice by applying pulsed electric field (PEF) treatment. The effect of non-thermal PEF treatment on physicochemical and sensory properties of apple juice was examined by measuring changes in vitamin C contents, colors, flavors and sensory properties. Color of PEF and heat treated apple juices was not significantly different from each other. Vitamin C content of PEF treated apple juice was close to that of fresh apple juice, but was much higher than that of heat treated apple juice. Heat treated apple juice lost 70% of flavor components, whereas PEF-treated apple juice lost only 15%. Sensory scores of PEF treated apple juice were significantly higher than heat-treated one in flavor, taste and overall acceptability. In conclusion, PEF treated apple juice had superior physico-chemical and sensory properties to heat-treated one.

  • PDF

Alternating Magnetic Field Crystallization of Amorphous Si Films

  • Kang, K.H.;Park, S.H.;Lee, S.J.;Nam, S.E.;Kim, H.J.
    • Journal of Information Display
    • /
    • v.4 no.1
    • /
    • pp.34-37
    • /
    • 2003
  • We investigate the solid phase crystallization of amorphous Si films on glass substrates under alternating magnetic field induction. The kinetics of crystallization are found to be greatly enhanced by alternating magnetic field. While complete crystallization takes heat treatment of more than 14 hours at 570$^{\circ}C$, it can be reduced by applying the megnetic field to 20 minutes. It is assumed that the enhancement of crystallization is associated with an electromotive force voltage generated by alternating magnetic field. This electric field applied in the amorphous Si may possibly be the reason for acceleration of the atomic mobility of crystallization through the modification of atomic potentials

Development of a Technique to Prevent Bolt Looseness and to Decrease in Quantity for the Plate Type Heat Exchanger Used in Large Craft (선박용 판형 열교환기의 볼트풀림방지 및 수량최소화기법 개발)

  • Kim, Ho-Yoon;Bae, Won-Byong;Jang, Young-Jun;Han, Seung-Moo;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.44-51
    • /
    • 2007
  • There are many methods to assemble various parts of a product, and one of them is the bolting system widely used in a industrial field due to the merits; easiness to obtain strong tightening force, simplicity of assemble or disassemble in order to repair, substitution or cleaning, and so on. But this bolting system needs attachments not to let a bolt loose and they are an important factor to cost a great deal. In this study, some equations are suggested and FE analyses are carried out to verify the cause of the bolt looseness occurring in the tightening process. And because the number of bolts in the bolting system has been decided by empirical know-how of designers in the field, safety rate in the plate type heat exchanger is often too high. Therefore the equations to decrease in quantity are suggested in consideration of the relationship between a critical shearing force acting on the screw and a normal force acting on the cooling plate by the working fluid.

Development of Technology for Network Construction using Wide Area Energy (광역에너지이용 네트워크 구축 기술개발)

  • Kim, Lae-Hyun;Chang, Won-Seok;Hong, Jae-Jun
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.125-138
    • /
    • 2008
  • In order to diversify energy source and to utilize it effectively, it requires to construct an integrated energy management system in a wide area. This research paper explores the core technology of network construction using wide area energy and applies the technology to the field. In specific, it examines the business model by developing l) construction technology of optimum integrated system for thermal supply on wide area network related IT technology, 2) technology of unutilized energy as heat pump using exhaust gas latent heat, and 3) thermal transportation and storage technology using various sources, and by evaluating the applicability and marketability of the model in the field.

Electro-thermal analysis of contacts and connections in VCB under high electric current by finite element methods (유한요소법에 의한 VCB 접속부의 대전류에 대한 전열해석)

  • Kang, Woo-Jong;Huh, Hoon;Kang, Kyeong-Rok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.715-722
    • /
    • 1998
  • A large electric system of a vacuum circuit breaker(VCB) has been studied for the electro-thermal analysis by finite element methods. Since the heat generation in VCB causes not only energy loss but deterioration of the VCB system with oxidization of parts, the overheating of the system must be prevented. For the analysis, a finite element formulation is derived for both electric analysis and thermal analysis that are coupled together. Two sets of formulations are uncoupled after finite dimensional approximation. First, the electric potential is obtained for the entire field and scaled to the given electric current. The electric field obtained is then used to calculate the heat generation in the VCB system including contacts and connections for the calculation of the temperature distribution in the entire domain. The finite element analysis is carried out to study the effect of shapes and locations of contacts and connections. From the results, the existing VCB has been modified to enhance its capacity with reduction of heat generation and temperature elevation.

A Numerical Study on Cooling Characteristics by Impinging Jet at a Square Heating Element with Duct (충돌제트에 의한 덕트내 사각발열체의 냉각특성에 관한 수치해석적 연구)

  • Yoon Jeong-Ho;Kim Si-Boem;Kim Dong-Kyun;Lee Chi-Woo;Kim Ji-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.42-48
    • /
    • 2005
  • Because Impinging jet has excellent heat & mass transfer characteristics. it has many advantages of cooling. drying. etc and widely applied at industrial fields. Therefore, there have been many experimental investigations and theoretical studies about Impinging jet. The present study is about a cooling characteristic by Impinging jet for a Square Plate on Duct and investigated this characteristic through three-dimensions numerical analysis, using FLUENT. As the result of this study, heat transfer effect is the most appropriate condition when the ratio of distance is 6 between nozzle exit diameter and heat source. diameter of duct is 90mm and height of duct is 60mm. In addition. under the influence of injected jet. stagnant fluid flow into free jet field and this affected the whole flow field. So the shape of duct is a important factor and the researcher confirmed the need of investigation about duct.

Characteristics of Temperature Variation in Urban and Suburban Areas During Winter (겨울철 도시지역과 교외지역의 기온변화 특성)

  • Kwon, Sung-Ill;Kim, Jin-Soo;Park, Jong-Hwa;Oh, Kwang-Young;Song, Chul-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.55-63
    • /
    • 2008
  • We investigated characteristics of temperature variation in urban and suburban areas(e.g., paddy field, upland, park, residential area) and urban heat island(UHI) during winter(December 2005 to February 2006). The daily maximum air temperature was not significantly different between suburban and urban areas, whereas the daily minimum air temperatures were significantly lower in the suburban areas than that in the residential area. The wind speed in the urban park(0.3 m/s) was much lower than that in the paddy fields(2.3 m/s), likely due to an urban canopy layer formed by high buildings. The UHI intensity was represented by differences in daily minimum temperatures between urban residential and paddy field areas. The UHI intensity($4.1^{\circ}C$) in winter was larger than that($2.6^{\circ}C$) in summer. This may be because a stable boundary layer develops in the winter, and thereby this inhibits diffusion of heat from surface.

A Study on Temperature Field and Contact Pressure in Ventilated Disc-Pad Brake by 3D Thermo-mechanical Coupling Model (3차원 열-기계 커플링 모델에 의한 벤틸레이티드 디스크-패드 브레이크의 온도 분포와 접촉 압력에 관한 연구)

  • Hwang, Pyung;Seo, Hee-Chang;Wu, Xuan
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.421-426
    • /
    • 2009
  • The brake system is important part of automobile safety system. The disc brake system is divided two parts: the rotating axisymmetrical disc and the stationary pads. During braking, the kinetic energy and potential energy of moving vehicle were converted into the thermal energy through frictional heat between the brake disc and the pads. The frictional heat, which is generated on the interface of the disc and pads, can cause high temperature during the braking process. The object of present work is to determine temperature and thermal stress, to compare to simulation results and experimental results in the disc by partial 3D model of ventilated disc brake with appropriate boundary conditions. In the simulation process, the mechanical loads were applied to the thermo-mechanical coupling analysis in order to simulate the process of heat produced by friction.

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

Analysis of Anisotropic Turbulent Heat Transfer in Nuclear Fuel Bundles (핵연료 집합체내의 비등방성 난류 열전달에 관한 해석적 연구)

  • Kim, Sin;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.35-46
    • /
    • 1988
  • The prediction of clad surface temperatures is important to the design and the safety anlaysis of nuclear reactor. The accurate prediction requires the detailed knowledge of the flow structure and heat transfer, which is complicate due to anisotropic turbulent phenomena. A two-equation model including anisotropic eddy viscosity model is applied to forecast the velocity distribution. And the temperature field is calculated with uniform wall heat flux. The Galerkin's weighted residual finite element method has been used to calculate the turbulent quantities right up to the wall. The numerical results show good agreement with available data and that turbulence anisotropy strongly affects on the mean flow and thus the temperature field. And Nu-P/D correlation is established for sodium coolant in close-packed equilateral triangular bundle in the P/D range of 1.05 to 1.30.

  • PDF