• Title/Summary/Keyword: Fault line

Search Result 1,138, Processing Time 0.029 seconds

Primary Resistance Compensation of Linear Induction Motor Using Thermocouple (Thermocouple을 이용한 선형 유도전동기의 1차측 저항 보상)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.742-747
    • /
    • 2006
  • This paper describes online stator-resistance estimation of a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC), where the resistance value is derived from stator-winding temperature estimation using thermocouple. In this paper, corrected stator resistance has an error in actuality measurement resistance. So compensation coefficient $\kappa$ which is decided through comparison and verifying several times relation of calculated resistance and measured motor line-line resistance. The stator-winding temperature information can also be used for monitoring, protection, and fault-tolerant control of the machine. Also, this paper reports the LIM's responses of the flux measured by the proposed stator resistance compensation algorithm.

  • PDF

A Power-line Frequency Monitoring Intelligent Electronic Device(IED) Platform (전력선 주파수 모니터링을 위한 Intelligent Electronic Device(IED) 플랫폼)

  • Jeon, Hyeon-Jin;Yi, Don-Jin;Jeon, Jun-Gil;Chang, Tae-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.1047-1049
    • /
    • 2009
  • This paper presents an intelligent electronic device(IED) platform which is based on a new frequency estimation algorithm. The IED platform features not only the accurate estimation of frequency but also the fast network-based transmisstion of fault data and waveforms. The simulation results show that the proposed frequency estimation algorithm improves convergence speed, and has lower frequency estimation error compared with those of conventional algorithms. The network-based IED is designed to ensure transmission latency being less than 1.0% of sampling interval.

A distance Relaying Algorithm Based on Numerical Solution of a Differential Equation for Transmission Line Protection (송전선 보호용 적분근사 거리계전 알고리즘)

  • 조경래;정병태;홍준희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.711-720
    • /
    • 1994
  • A distance relaying algorithm for detecting faults at power transmission line is presented in this paper. The algorithm is based on differential equation from relaton between voltage and current, which is composed of lumped resistance and inductance. During the fault transient state,the voltage and current signals are severely distorted due to the exponentially decaying DC offset and high frequency components, In spite of using small data, the presented integral method to evaluate R and L from voltage and current has high performance against these harmonics including DC offset. Therefore, the presented algorithm can be implemented with only a low order anti-aliasing analog filter and dosen't need any digital filter to remove specific components.

  • PDF

Monitoring and On-Line Fault Diagnosis for the Automation of a Concrete Plant (콘크리트 플랜트의 자동화를 위한 감시 및 온-라인 고장진단에 관한 연구)

  • Kong, Young-J.;Chang, Tae-G.;Yang, Won-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.258-260
    • /
    • 1993
  • This paper presents an on-line monitoring and control system designed for the automation of a Concrete plant. The system is based on the combined structure composed of a general purpose PLC (Plogrammable Logic Controller) and a personal computer. Simulation results are ahem to illustrate the system operation. Preconstructed rules are applied to the plant data for the diagnosis of the weighing process in the simulation.

  • PDF

A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage (배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구)

  • Kwak, D.K.;Park, D.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF

The Analysis of Faults for the Excitation System of Generator (발전기 여자시스템의 에러 해석)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Paik, Doo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1047-1049
    • /
    • 2005
  • Hydraulic power plant is operated for peak load and frequently start-stop because of no continuous operation. So the fault can happen due to field voltage swing in the middle of starting or reactive power swing on the line. On this research, we want to analyze that this status influence on line and generator. we hope this research can contribute to the power quality improvement.

  • PDF

Optimum Support Pattern Design of the Tae-Gu Subway Tunnel (대구 지하철 터널의 적정지보패턴 선정에 관한 연구)

  • 지왕률;최재진
    • Tunnel and Underground Space
    • /
    • v.4 no.2
    • /
    • pp.119-131
    • /
    • 1994
  • This is a Double-Track Railway tunnel in typical Tae-Gu black and gray shale forming part of the No.1 Line of the Tae-Gu Subway. The main fault zone at tunnel is a moderately to highly weathered and closely jointed zone, 0.5 m wide with associated paralled jointing which is slickensided and fractured. After excavation by blasting, the soft rocks should need to be reinforced with optimal supporting pattern which might be better redesigned through the consideration of the results of in-situ rock measurements at the field. Performances fo the field tests included Point Load Test, Schmidt Hammer Test, and field joint measurement gave the detail data for the optimum support design and safe excavation of the No.1 Line of Tae-Gu Subway at the No.1-7 consturction site adn the safety of this redesigned supports system was analysed by the FDM program FLAC.

  • PDF

Design of GA-Fuzzy Controller of TCSC for Enhancement of Power System Stability (전력계통의 안정도 향상을 위한 TCSC의 GA-퍼지 제어기 설계)

  • Chung Mun Kyu;Chung Hyeng Hwan;An Byung Chul;Wang Yong Peel
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.225-235
    • /
    • 2005
  • In this Paper, it was designed the GA-fuzzy controller of a Thyristor Controlled Series Capacitor(TCSC) for enhancement of power system stability. The newly designed controller of TCSC was designed to overcome the nonlinearity such as operating point change of power system as well as to respond to disturbances as uncertainties of line parameters and line fault. So, fuzzy controller by intelligent control theory was used for it. And the fuzzy controller was optimized from a genetic algorithm for complements the demerit such as the difficulty of the component selection of fuzzy controller namely. scaling factor. membership function and control rules. Nonlinear simulation results show that the proposed control technique is superior to conventional PSS in dynamic responses over the wide range of operating conditions and is convinced robustness and reliableness in view of structure.

Anisotropy of Magnetic Susceptibility (AMS) of the Quaternary Faults, SE Korea: Application to the Determination of Fault Slip Sense and Paleo-stress Field (한반도 남동부 제4기 단층의 대자율이방성(AMS): 단층의 운동감각과 고응력장 해석)

  • Cho, Hyeongseong;Kim, Min-Cheol;Kim, Hyeonjeong;Son, Moon
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.75-103
    • /
    • 2014
  • The Quaternary faults are extensively observed along major inherited fault zones (i.e. Yangsan Fault System, Ulsan Fault, Yeonil Tectonic Line, Ocheon Fault System) in SE Korea. Their geometry and kinematics provide a very useful piece of information about the Quaternary crustal deformation and stress field in and around Korean Peninsula. Using magnetic fabrics (AMS), we attempted to determine the slip senses of Jinti, Mohwa, Suseongji2, and Wangsan faults and then interpreted the fabric development process of fault gouge and the characteristics of stress field during the Quaternary. All the magnetic fabrics of the faults, except the Wangsan Fault, consistently indicate a dominant reverse-slip sense with weak strike-slip component. Most of the oblate fabrics are nearly parallel to the fault surface and the anisotropy degrees generally increase in proportion to the oblatenesses. These results suggest that the fabrics of the fault gouges resulted from a progressive deformation due to continuous simple shear during the last reactivation stage as reverse faulting. It is also interpreted that the pre-existing fabrics were overwhelmed and obliterated by the re-activated faulting. Paleostress field calculated from the fault slip data indicates an ENE-WNW compressive stress, which is in accord with those determined from previous fault tectonic analysis, focal mechanism solution, and hydraulic fracturing test in and around Korean Peninsula.

Development History of Neotectonic Fault Zone in the Singye-ri Valley, Oedong-eup, Gyeongju, Korea (경주시 외동읍 신계리 계곡에 발달하는 신기 단층대 발달사)

  • Kang, Ji-Hoon;Son, Moon;Ryoo, Chung-Ryul
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.4
    • /
    • pp.349-359
    • /
    • 2020
  • The Ulsan Fault Zone (UFZ) of NNW trend is developed in the Gyeongsang Basin, the southeastern part of the Korean Peninsula, and the Quaternary faults have been found around the UFZ. The faults generally thrust the Bulguksa igneous rocks of Late Cretaceous-Early Tertiary upon the Quaternary deposits or are developed within the Quaternary deposits. They mainly show the reverse-slip sense of top-to-the west movement. The lines connecting the their outcrop sites show a zigzag-form which is similar to the orientation of their fault surfaces which show the various trends, like (W)NW, N-S, (E)NE, ENE trends. The E-W trending dextral strike(-slip) fault is found in the Quaternary deposits of the Singye-ri valley. It cuts the N-S trending reverse fault and are cut by the N-S trending thrust fault again. Two types of at least two times of Quaternary tectonic movements related to the formation of neotectonic fault zone in the Singye-ri valley are considered from such the geometric and kinematic characteristics of Quaternary faults. One is the reverse faulting of N-S trend by the E-W directed 1st compression and associated the strike-slip tear faulting of E-W trend, and then the thrust faulting of N-S trend by the E-W directed 2nd compression. The other is the reverse faulting of N-S trend, and then the dextral strike-slip faulting of E-W trend by the NW-SE directed compression, and then the thrust faulting of N-S trend. In this paper is suggested the development history of Singye-ri neotectonic fault zone on the basis of the various orientations of Quaternary fault surfaces around the UFZ, and the zigzag-form connecting line of their outcrop sites, and the compressive arc-shaped lineaments which convex to the west reported recently in the Yangsan Fault Zone.