• Title/Summary/Keyword: Failure correlation

Search Result 585, Processing Time 0.03 seconds

Fatigue Life Analysis and Prediction of 316L Stainless Steel Under Low Cycle Fatigue Loading (저사이클 피로하중을 받는 316L 스테인리스강의 피로수명 분석 및 예측)

  • Oh, Hyeong;Myung, NohJun;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1027-1035
    • /
    • 2016
  • In this study, a strain-controlled fatigue test of widely-used 316L stainless steel with excellent corrosion resistance and mechanical properties was conducted, in order to assess its fatigue life. Low cycle fatigue behaviors were analyzed at room temperature, as a function of the strain amplitude and strain ratio. The material was hardened during the initial few cycles, and then was softened during the long post period, until failure occurred. The fatigue life decreased with increasing strain amplitude. Masing behavior in the hysteresis loop was shown under the low strain amplitude, whereas the high strain amplitude caused non-Masing behavior and reduced the mean stress. Low cycle fatigue life prediction based on the cyclic plastic energy dissipation theory, considering Masing and non-Masing effects, showed a good correlation with the experimental results.

Development and Implementation of Dam Safety Management System (댐 안전관리 시스템의 개발 및 운용)

  • Jeon, Je Sung;Lee, Jong Wook;Shin, Dong Hoon;Park, Han Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.121-130
    • /
    • 2008
  • Recently, we can see an increasing amount of dam damage or failure due to aging, earthquakes occurrence and unusual changes in weather. For this reason, dam safety is gaining more importance than ever before in terms of disaster management at a national level. Therefore, the government is trying to come up with an array of legal actions to secure consistent dam safety. Other dam management organizations are also taking various institutional and technical measures for the same purpose. In this study, Dam Safety Management System, KDSMS, has developed for consistent and efficient dam safety management. The KDSMS consists of dam and reservoir data, a hydrological information system, a field inspection and data management system, a instrumentation and monitoring system including earthquake monitoring, a field investigation and safety evaluation system, and a collective information system. The KDSMS is a kind of enterprise management system which has been developed to deal with safety management of each field, research center, and headquarter office and their correlation as well as detailed safety information management.

Logical Analysis for Parameters of Radioactive waste Policy using System Dynamics Technique (시스템 다이내믹스 모델링을 통한 중.저준위방사성폐기물시설 부지선정 영향 인자 분석)

  • Lee, Y.J.;Cho, S.K.
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.77-87
    • /
    • 2008
  • Decision-making of the site for the medium and low-level radioactive-waste disposal facilities in 2005 can be estimated as a success. But the limits exposed during the process still remain as problems to be solved. Analyzing the causes of success and failure of the policy and their correlation was expected to provide an effective guideline on future policies. The analysis shows that the transparency of policy makers, the level of community supports and the public relations are decisive factors. System dynamics, a synthetic analyzing tool, is used as a methodology for policy analysis. The result of the system dynamics analysis shows that public confidence is to be the key role to for and against logics when transparency of stakeholder, subsidy and public information are set as adjustable parameters. Public confidence takes a role of leverage that can convert tendency of conclusion by the opinion which influenced by selected parameters.

Estimation of Ventricular Assist Device Outflow with the Pressures in Air Pressure Line (공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정)

  • Kim, Young Il;Her, Keun;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.119-124
    • /
    • 2014
  • A Ventricular assist device (VAD) is one of the most efficient treatments to raise the survivability of the end stage heart failure patient. However, some of LVAD patients have died for the failures and improper control of LVAD. To detect critical dangers in LVAD, the monitoring methods of LVAD outflow have been requested, because it can be affected by patient's hemodynamic states and abnormal conditions of LVAD. In the case of an external pulsatile LVAD, the air movement through the air line can be used to estimate LVAD outflow. In this study, the air movement in the air-line of the extracorporeal pulsatile LVAD was measured with a differential pressure sensor between different points. The precise estimation of air movement could be achieved by additional measurement of air pressure. In a series of in-vitro experiments, the LVAD outflow were changed according to the afterload of LVAD and the differential pressure of LVAD didn't have close correlation with the LVAD outflow that were measured with an ultrasonic flowmeter at the same time. However, new precise estimation with the data from differential pressure and one point pressure in the air-line showed higher correlations with LVAD outflow.

REWETTING EFFECT OF WATER-BASED PRIMER ON THE AIR-DRIED DENTIN (공기건조된 상아질에 대한 수분함유 primer의 재습윤효과)

  • Kim, Ki-Young;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.498-503
    • /
    • 2003
  • The purpose of this study was to evaluate the rewetting effect of water-based primer on the air-dried dentin. In this in vitro study, freshly extracted non-caries human molars and three-step adhesive system(SBMP) were used. Freshly extracted non-caries human molars and three-step adhesive system(SBMP) were used. Flat occlusal dentin surface were prepared using low-speed diamond saw, Prepared teeth were randomly divided into three groups. Group 1.(W): etched(35% phosphoric acid for 15s) and blot-dried, Group 2.(5D): 5s air-dried, Group 3.(30D): 30s ail-dried, To obtain color contrast in CLSM observation, primer was mixed with rhodamine B and bonding resin was mixed with fluorescein. Microscopic sample of each group were obtained after longitudinal section. Morphological investigation of resin-dentin interface and thickness of hybrid layer measurement using CLSM were done. Microtensile bond strength for each specimen was measured. Specimen were observed under microscope to examine the failure patterns of interface between resin and dentin. The results of this study were as follows: 1. The results(mean) of Thickness of hybrid layer were W:19.67, 5D:20.9, 30D:10$\mu\textrm{m}$. Only 30D had statistically significant differences to Wand 5D(P<0.05). 2. The results(mean) of Microtensile bond strength were W:16.02, 5D:14.69, 30D:11.14MPa. Only 30D had statistically significant differences to Wand 5D(P<0.05). 3. There were positive correlation between Thickness of hybrid layer and microtensile bond strength(P<0.05).

Vulnerability Analysis of Network Communication Device by Intentional Electromagnetic Interference Radiation (IEMI 복사에 의한 네트워크 통신 장비의 취약성 분석)

  • Seo, Chang-Su;Huh, Chang-Su;Lee, Sung-Woo;Jin, In-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • This study analyzed the Vulnerability of Network Communication devices when IEMI is coupled with the Network System. An Ultra Wide Band Generator (180 kV, 700 MHz) was used as the IEMI source. The EUTs are the Switch Hub and Workstation, which are used to configure the network system. The network system was monitored through the LAN system configuration, to confirm a malfunction of the network device. The results of the experiment indicate that a malfunction of the network occurs as the electric field increases. The data loss rate increases proportionally with increasing radiating time. In the case of the Switch Hub, the threshold electric field value was 10 kV/m for all conditions used in this experiment. The threshold point causing malfunction was influenced only by the electric field value. The correlation between the threshold point and pulse repetition rate was not found. However, in case of the Workstation, it was found that as the pulse repetition rate increases, the equipment responds weakly and the threshold value decreases. To verify the electrical coupling of the EUT by IEMI, current sensors were used to measure the PCB line inside the EUT and network line coupling current. As a result of the measurement, it can be inferred that when the coupling current due to IEMI exceeds the threshold value, it flows through the internal equipment line, causing a malfunction and subsequent failure. The results of this study can be applied to basic data for equipment protection, and effect analysis of intentional electromagnetic interference.

Analysis on Waveform of Leakage Current of Contaminated EPDM Insulators by Salt Fog (Salt fog에 의한 오손된 EPDM애자의 누설전류 파형 분석)

  • Park, Jae-Jun;Song, Young-Chul;Kim, Jeong-Boo;Lee, You-Min;Lee, Hyun-Dong;Jung, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.36-41
    • /
    • 2003
  • This paper presents the results of power spectra using the fundamental and low frequency harmonic components of leakage current waveform to study aging on contaminated EPDM insulator(was serviced during 1997-2001, region Pohang, korea) under salt fog conditions. Experiments have been conducted in the chamber salt fog and at the 16KVrms. The salt contents adjusted as 0g,25g,50g and 75g per liter of deionized water. The onset of dry-band arcing on polymer insulators could be determined by signal processing the low frequency harmonics components. A correlation has been found between the fundamental and low harmonic components of power spectra on leakage current. Where aging could be associated with an increase in the level of both the fundamental and low frequency harmonics components of leakage current. Surface aging for contaminated EPDM insulators occurred when the fundamental component of leakage current was greater then some level On the other hand, when the polymer insulator approached failure, the fundamental component of leakage current reached relatively high values and low frequency harmonics components of the leakage current trended to decrease. The results suggest that both the fundamental and low frequency harmonics of leakage current can be used as a tool to determine both the beginning of aging and before flashover, end of life EPBM insulator in salt fog.

  • PDF

Correlation Study Between Anemias with Higher MCV and Lower MCHC

  • Choi, Woo-Soon;Kim, Hee-Sang
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • The purpose of this study was to evaluate the significance of higher than normal mean corpuscular volume (MCV) and lower than normal mean corpuscular hemoglobin concentration (MCHC) in 20 patients. The hemoglobin (Hb), red blood cell indices (MCV, MCH, MCHC,), red cell distribution width (RDW), serum ferritin, serum iron (Fe) and total iron binding capacity (TIBC) were measured and the transferrin saturation were calculated. 18 (90.0%) cases were categorized as chronic diseases. Chronic renal failure, malignancy, and bleeding were all related to the cases. The mean values of hemoglobin was $9.5{\pm}2.14g/dL$; the MCV was $29.0{\pm}2.8fL$; the MCH was $30.9{\pm}1.0pg$; the MCHC was $31.2{\pm}0.5%$; the RDW was $17.0{\pm}3.6%$; serum Fe was $39{\pm}21{\mu}g/dL$; the TIBC was $219.7{\pm}108.8{\mu}g/dL$; transferrin saturation was $19.2{\pm}9.9%$ and ferritin was $445.5{\pm}499.6{\mu}g/L$ in the patients. The WHO criteria for hemoglobin of patients confirms anemia in 18 of the 20 (90.0%) cases. Anemia of chronic disease was shown in 11 (73.3%) cases; acute gastric ulcer with hemorrhage in 1 (6.7%) case; iron deficiency anemia in 1 (6.7%) case; 2 patients (13.3%) were of normal cases. There were changes in the baseline Hb level results of the 19 (95.0%) cases while no change was shown in 1 case. As a result, diseases associated with anemia and bleeding where the MCV is higher than the normal range and MCHC is lower than normal range are considered relevant findings.

  • PDF

An Empirical Study on the Effect of Informatization of Small and Medium Manufacturers on Business Performance (중소제조기업의 정보화가 기업 성과에 미치는 영향에 관한 실증연구)

  • Joo Seok-Jeong;Park Seong-Kyu;Kim Na-Rang;Hong Soon-Goo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.2
    • /
    • pp.86-97
    • /
    • 2006
  • From the mid 1990's, the scale of IS had been growing, which resulted in increasing number of failure projects. As a result, the measurement of IS performance was a growing concern. Moreover, the need for research on the relation between IT investment and performance that isfd the concern of CEOs has been raised. In this study, the correlation between the IS functionality and investment was discovered based on the IS success model suggested by DeLone & McLean(1992), a business information system evaluation model by Lee Kuk Hie(1992), a balanced score card by Kaplan & Norton(1992). As a result of the LISREL analysis, the investment in the IS has a positive impact on the quality of both information systems and information. In turn, the quality of both information systems and information have a positive impact on the end-user satisfaction, the end-user satisfaction on the financial performance, customer satisfaction, and internal business processes. This study showed that sufficient investment in IS improved business performance

  • PDF

Predictive Factors for a Kyphosis Recurrence Following Short-Segment Pedicle Screw Fixation Including Fractured Vertebral Body in Unstable Thoracolumbar Burst Fractures

  • Kim, Gun-Woo;Jang, Jae-Won;Hur, Hyuk;Lee, Jung-Kil;Kim, Jae-Hyoo;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.3
    • /
    • pp.230-236
    • /
    • 2014
  • Objective : The technique of short segment pedicle screw fixation (SSPSF) has been widely used for stabilization in thoracolumbar burst fractures (TLBFs), but some studies reported high rate of kyphosis recurrence or hardware failure. This study was to evaluate the results of SSPSF including fractured level and to find the risk factors concerned with the kyphosis recurrence in TLBFs. Methods : This study included 42 patients, including 25 males and 17 females, who underwent SSPSF for stabilization of TLBFs between January 2003 and December 2010. For radiologic assessments, Cobb angle (CA), vertebral wedge angle (VWA), vertebral body compression ratio (VBCR), and difference between VWA and Cobb angle (DbVC) were measured. The relationships between kyphosis recurrence and radiologic parameters or demographic features were investigated. Frankel classification and low back outcome score (LBOS) were used for assessment of clinical outcomes. Results : The mean follow-up period was 38.6 months. CA, VWA, and VBCR were improved after SSPSF, and these parameters were well maintained at the final follow-up with minimal degree of correction loss. Kyphosis recurrence showed a significant increase in patients with Denis burst type A, load-sharing classification (LSC) score >6 or DbVC >6 (p<0.05). There were no patients who worsened to clinical outcome, and there was no significant correlation between kyphosis recurrence and clinical outcome in this series. Conclusion : SSPSF including the fractured vertebra is an effective surgical method for restoration and maintenance of vertebral column stability in TLBFs. However, kyphosis recurrence was significantly associated with Denis burst type A fracture, LSC score >6, or DbVC >6.