• Title/Summary/Keyword: Eyesight

Search Result 127, Processing Time 0.03 seconds

Histogram Specification Method Development for Accurate Visual Inspection (정확한 비전 검사를 위한 히스토그램 지정 기법 개발)

  • Park, Se-Hyuk;Kang, Su-Min;Han, Kwang-Hee;Huh, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.145-146
    • /
    • 2008
  • The appearance inspection of various electronic products and parts has been executed by the eyesight of human. But inspection by eyesight cannot bring about uniform inspection result. Because the appearance inspection result by eyesight of human is changed by condition of physical and spirit of the checker. So machine vision inspection system is currently used to many appearance inspection fields instead of the checker. However the inspection result of machine vision is changed by the illumination of workplace. Therefore we proposed histogram specification in this paper for machine vision inspection accuracy. As a result of histogram specification algorithm, we could increase the exactness of visual inspection and prevent system error from physical and spirit condition of human. More specifically, average inspection error rate was 7.5[%] in existing inspection method but we could see 0.6[%] error rate after applying the algorithm which is presented in this paper.

  • PDF

Image Separation Average Value Matching Method Development for Accuracy Improvement of Appearance Inspection (외관 검사의 정확도 향상을 위한 영상 분할 평균값 매칭 기법 개발)

  • Park, Se-Hyuk;Kang, Su-Min;Huh, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.445-446
    • /
    • 2007
  • The goal of this paper is accuracy improvement of appearance inspection by using image separation average value matching method. The appearance inspection of various electronic products and parts has been executed by the eyesight of human. But inspection by eyesight can't bring about uniform inspection result. Because the appearance inspection result by eyesight of human is changed by condition of physical and spirit of the checker. So machine vision inspection system is currently used to many appearance inspection fields instead of the checker. However the inspection result of machine vision is changed by the illumination of workplace. Therefore we have used a average value matching in this paper for improvement of vision inspection accuracy and could increase inspection accuracy of vision system. In other words, we made an effort for elevation of vision inspection accuracy by making the identical image separation average value of reference image and input image. Also this system has been developed only using PC, CCD Camera and Visual C++ for universal workplace.

  • PDF

Accuracy of Visual Acuity and Spectacles Wearing Among the Middle and High School Students in Busan (부산시내 중고등학생의 시력과 안경착용 실태)

  • Lee, Jeong-Ha;Choi, Woon Sang;Lee, Myung Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.53-59
    • /
    • 2009
  • Purpose: The aims of this study are to conduct a fact-finding survey of eyeglasses use based on the visual acuity of middle and high school students in Busan. Methods: A total of 821 middle and high school students from four different schools participated by Self-administered qustionnaire test on July, 2007. Results: Among these students, 74.3% of the students had low vision and 66.26% of the students wore eyeglasses. The percentage of non glasses-wearers were 13.77% in low vision and 15.26% of the students had low vision in glasses-wearers. The reason why they did not wear eye glasses and why they did not change eyeglasses prescription was they did not feel any inconvenience in their usual life. Conclusions: Many students have bad eyesight due to limited spheres of environment and they do not feel any inconvenience of non-wearing eyeglasses in spire of their bad eyesight.

  • PDF

A Measurement Algorithm using Gray-level Thresholding in Automatic Refracto-Keratometer (그레이-레벨 한계 기법을 이용한 자동 시각 굴절력 곡률계의 측정 알고리즘)

  • Sung, Won;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.727-734
    • /
    • 2002
  • Currently. people become interested in the development of measuring instrument related to eyesight. In this study, we developed software of electronic part in automatic refracto-keratometer. If an automatic system, which uses images from an optical instrument, can inform the in-spector of an accurate eyesight measured value after the internal process, the frequency of mistakenly observed value will be reduced considerably. This software is using morphological filtering and gray-level signal enhancing techniques. The morphological filtering is the first process, from images of the optical instrument, to transform an original image which is hard to process into manageable one. The second process is a signal enhancing technique to the first processed image using gray -level thresholding technique and is used to reduce an error caused by the variety in distribution of the gray value of image. Therefore, this software system in electronic part will make more effective eyesight measurement by reducing the error effectively when applied to the optical image which is difficult to get accurate measurement value.

Vision Inspection Method Development which Improves Accuracy By using Power-Law Transformation and Histogram Specification (멱함수 변환과 히스토그램 지정을 사용하여 정확도를 향상시킨 Vision 검사 방법 개발)

  • Huh, Kyung-Moo;Park, Se-Hyuk;Kang, Su-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.11-17
    • /
    • 2007
  • The appearance inspection of various electronic products and parts has been executed by the eyesight of human. But inspection by eyesight can't bring about uniform inspection result. Because the appearance inspection result by eyesight of human is changed by condition of physical and spirit of the checker. So machine vision inspection system is currently used to many appearance inspection fields instead of the checker. However the inspection result of machine vision is changed by the illumination of workplace. Therefore we have used a power-law transformation and histogram specification in this paper for improvement of vision inspection accuracy. As a result of these power-law transformation and histogram specification algorithm, we could increase the exactness of vision inspection and prevent system error from physical and spirit condition of human. Also this system has been developed only using PC, CCD Camera and Visual C++ for universal workplace.

Comparison between Accommodative Response Change on the Full Vision Correction and Low Vision Correction (완전교정과 저교정 상태에서 조절반응 변화량의 비교)

  • Bae, Sung-Hyun;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • Purpose: The study tried to figure out accommodative changes by measuring accommodative response, appearing on the full vision correction and low vision correction, with both eyes open-view auto-refractometer (Nvision-K5001, Shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 79 college students (58 males and 21 females) aged between 20 and 30($21.14{\pm}2.00$), by measuring accommodative changes with fixation distance at 1.0 m for eyesight of 1.0 after full version correction. The distances of 5.0 m, 1.0 m, 0.50 m, 0.33 m and 0.25 m for eyesight of 0.8, 0.7 and 0.6 after low vision correction arbitrarily added plus lens were applied. Results: the shorter measure fixation distances were, the greater changes accommodative response showed a tendency in the state of both full vision correction and low vision correction(0.7). The state of full vision correction showed a greater change of accommodative response than that of low vision correction(0.7). Both right and left eyes showed low accommodative responses in the state of low vision correction(0.7) than that of full vision correction. As a result of analyzing accommodative response at an eyesight of 0.8, 0.7, and 0.6 after low vision correction, the poorer eyesight was the lower accommodative response. Conclusions: Low vision correction from a near distance is expected to avoid unnecessary accommodative response, make eyes relaxed and prevent accommodative function disorder.

A study on the spectacles-wearing and eyesight health behavior of the middle school students (서울시내 일부 중학생의 시력 및 안경착용과 그에 따른 보건행태 조사연구)

  • Jeon, Ye-Jin;Kim, Myung
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.87-106
    • /
    • 1994
  • Owing to the use of many cultural facilities, the elevation of life standards and the high level progress of industry, visual impairment was on increasing trends. Especially due to studying for many hours, the myopia of adolescents became a serious social issue. The purpose of this study was to understand adolescent's wearing glasses and eyesight condition, whether the primary myopia factor and the subjective symptoms were different between the myopia group and the normal group, between the wearing glasses group and the non-wearing glasses group, and the effect on physical, mental and study activity of myopia. The subject of investigation was 627 middle school students in Seoul and the investigation was accomplished from July 7th, 1993 to July 12th, 1993. The data were analyzed by the percentage, x²-test, t-test and ANOVA of SPSS. The results were as followed; 1. The rate of the right and left eyesights higher than 0.8 in the normal group was 47.0%, and those less than 0.7 in the myopia group was 53.0%. In the boy students, the normal group was 54.1%, the myopia group was 45.9%. In the girl students, the normal group was 39.2%, the myopia group was 60.8%. Therefore the girl students' myopia rates were higher than the boy students', and this result was significant(p<0.01). 2. The rate of wearing glasses of the middle school students was 44.6%. The rate of wearing glasses of the girl students was 56.8%. The rate of wearing glasses of the girl students was higher than that of the boy students 43.2%. The rate of necessary glasses of the middle school students was 6.1% and the rate of necessary glasses of the boy students was 7.9%, the rate of necessary glasses of the girl students was 4.1%. 3. In case of a family member of the student wear glasses, the rate of wearing glasses was higher. 4. In the myopia group, the main reason for not wearing glasses was "Uncomfortable"(63.3% in the boy students, 40% in the girl students). In case of the girl students, "Nonpermission of their parents" was 18.7% and remarkably higher than 5.1% in case of the boy students. 5. The factor of myopia was that "The bad attitude of watching TV closely" was 19.9%, that "The dimly-lit room" was 6.6%. 6. In order to protect eyesight, the rate of the students who practiced "Looking at something from afar 3∼4times a day" was 37.3%, the rate of the students who did "Eye exercise" was 17.5%, the rate of the students who took "A medicine for promoting nutrition" was 12.9%. The rate of taking the medicine was higher than 3.5% in the normal eyesight group. 7. After near working, the point of subjective symptoms was higher in the myopia group than in the normal group and in the wearing glasses group than in the unwearing group and in the girl students than in the boy students. 8. The longer time to watch TV, the higher point of subjective symptoms. The longer distance to watch TV, the lower point of subjective symptoms(p<0.05).

  • PDF

A Case of Macular Edema Resulted from Branch Retinal Vein Occlusion (망막분지정맥폐쇄로 유발된 황반부종 치험 1례)

  • Kim, Ji-Hyon;Heo, Eun-Jung;Kwon, Kang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.2
    • /
    • pp.186-195
    • /
    • 2010
  • Objective : This study was performed to prove the effect of the oriental medical treatments like acupuncture, moxibustion, herbal medicine on macular edema resulted from branch retinal vein occlusion which could lead to terrible result like permanent visual loss at worst. Methods : The patient was treated 62 times, from July 15th, 2009 through May 12th, 2010. We used fundus photography and Dr. Hann's standard test chart for 5m to examinate the patient's eyesight. We used acupuncture, electropuncture, moxibustion and herbal medicine to treat the patient. We considered visual field, scotoma, metamorphopsia and vitreous floater to measure the effect of treatment. Results : After about 10 months of treatment, the eyesight of Rt eye was improved from 0.8 to 0.9, Lt. eye from zero to 0.3. The visual field turbidity were absolutely cleared. The scotomas in Lt. eye were reduced from 5 to 2. The metamorphopsia were improved. The vitreous floaters in Rt. eye were decreased from 5~6 to 1~2. Conclusion : These results show that the oriental medical treatment can be conservative measure to the macular edema resulted from branch retinal vein occlusion.

Prevalence of Cataract with Different Type of Lens Opacity in the Korean Population (한국 성인의 수정체 혼탁 유형에 따른 백내장의 유병률)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • Purpose: This study calculated the prevalence of cataract in Korean and examined corrected eyesight with different types of opacification of crystalline lens. Methods: Using the data of the national health and nutrition examination survey (NHANES), population-based and cross-sectional research were designed in this study. After dividing total 4,977 persons into different groups by age, from 40 to 95 and by sex, the prevalence of cataract with different types of opacification was investigated. The average age of the total subjects was $58.28{\pm}12.07$, and the number of men and women were 2,142(43.0%) and 2,835(57.0%), repectively. Eyesight was calculated when it was less than 0.63. Results: Among total 4,977 subjects, 40.6% (men 17.5%, women 23.1%) had cataract. Different prevalence rates were found with different types of cataract; nuclear cataract (56.3%), cortical cataract (23.4%), mixed cataract (16.2%), anterior subcapsular(3.0%), and posterior subcapsular (1.1%) in order. There was no difference among men and women by the types. And those in their 40's showed a higher prevalence of cortical cataract than those in the other age groups. Most of subjects whose corrected eyesight is less than 0.63 had anterior subcapsular cataract. Conclusions: The type of cataract having the highest prevalence was nuclear opacity. Moreover, epidemiologic investigation and prevention policy with different type of lens opacity seems to be required.

A Study on the Health Conditions of Male and Female Environmental Workers in Seoul (서울시 남$\cdot$여 환경미화원의 건강실태에 관한 고찰)

  • Kwon Young Eun;Suh Gil Hee;Kim Kyu-Sung;Choy Haeng-Gi;Jung Moon-Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.67-79
    • /
    • 1993
  • This study was designed to identify the general health conditions and high risk factors of the male & female environmental workers. Thereby. the results of this study were to provide useful data as a contribution to knowledge for health protection and promotion. The data used for this study were environmental workers' physical examination cards; the male environmental workers were 52 persons. and the female environmental workers 52 persons. The data were analyzed by descriptive statistics, t-test, Pearson correlation, and distinction analysis, using the SPSS program. The results of this study can be summarized as follows; 1. Thers was a significant statistical difference between the two groups as to height. eyesight. serum GPT, hematocrit. The variables having little difference between two groups were weight. systolic blood pressure. total cholesterol. creatinine. 2. The rate of revealed in significant health examination was extra-health discrimination rate $28.8\%$, significant result of illness rate $12.5\%$. injury-inflicting rate $7\%$. second-time urine test $5.7\%$. antigen positive 3.8%. hearing impairment $2.8\%$, urine protein positive $1.9\%$. and urine sugar positive $1.9%$. 3. The workers diagnosed as extra-health discrimination were 30 persons or $28.8\%$. There was a difference between two groups on the prevalence. In the male environmental workers. ten times live problems and six times pulmonary tuberculosis and three times circulatory problems were revealed the higher than thoes of the female environmental workers. 4. In the male environmental workers, the relationship between age and systolic blood pressure revealed a significant correlation (r=0.22. p<0.05). In the female environmental workers. there was a negative correlation between age and weight (r= 0.25, p<0.05). the relationship between age and total cholesterol correlated positively (r=0.30, p<'0.05). 5. In the male environmental workers, there was a negative correlation between working career and creatinine(r=-0. 22, p<0.05) In the female environmental workers, there was a positive correlation between working career and total cholesterol (r= 0.58, p<0.01). 6. There were significant differences on working career and creatinine accdording to the male and female environmental workers who had any problems through x-ray inspection. 7. There were significant differences on height. eyesight. serum GPT according to the male and female environmental workers who were diagnosed as extra-health discrimination. 8. The female environmental workers who were diagnosed as 'care' were positively correlated with weight (r= 0.26. p<0.05)' and systolic blood pressure (r= 0.30. p<0. 05). on the other hand. the left and right eyesight correlated nagatively(r=-0.15. r=-0.33. p<0.01). 9. The most influential variables on the male and female environmental workers' health condition were working career, height. and weight. And these three variables could help determine the two groups at the level of 81. 8 percentage.

  • PDF