• 제목/요약/키워드: External Pressure

검색결과 1,250건 처리시간 0.029초

광압력 센서의 설계 및 특성 (Design and characteristics of a fiber-optic pressure sensor)

  • 김영수;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.508-510
    • /
    • 1995
  • A fiber-optic pressure sensor is fabricated with a photoelastic glass material. To remove the influence of external pertubation along the optical fiber, a new referencing technique is proposed by using two light sources. LED with 870nm wavelength is used as light source for reference signal, and LED with 660nm wavelength is used as light source for modulation signal. The fiber-optic pressure sensor system shows good linearity within the pressure range of 0 to 5 $kg/cm^2$.

  • PDF

The Effects of Injector Nozzle Geometry and Operating Pressure Conditions on the Transient Fuel Spray Behavior

  • Koo, Ja-Ye
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.617-625
    • /
    • 2003
  • Effects of Injector nozzle geometry and operating pressure conditions such as opening pressure, ambient pressure. and injection pressure on the transient fuel spray behavior have been examined by experiments. In order to clarify the effect of internal flow inside nozzle on the external spray, flow details Inside model nozzle and real nozzle were alto investigated both experimentally and numerically. for the effect of injection pressures, droplet sizes and velocities were obtained at maximum line pressure of 21 MPa and 105 MPa. Droplet sizes produced from the round inlet nozzle were larger than those from the sharp inlet nozzle and the spray angle of the round inlet nozzle was narrower than that from the sharp inlet nozzle. With the increase of opening pressure, spray tip penetration and spray angle were increased at both lower ambient pressure and higher ambient pressure. The velocity and size profiles maintained similarity despite of the substantial change in injection pressure, however, the increased injection pressure produced a higher percentage of droplet that are likely to breakup.

Wind induced internal pressure overshoot in buildings with opening

  • Guha, T.K.;Sharma, R.N.;Richards, P.J.
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.1-23
    • /
    • 2013
  • The wind-induced transient response of internal pressure following the creation of a sudden dominant opening during the occurrence of high external pressure, in low-rise residential and industrial buildings was numerically investigated. The values of the ill-defined parameters namely the flow contraction coefficient, loss coefficient and the effective slug length were calibrated by matching the analytical response with the computational fluid dynamics predictions. The effect of a sudden i.e., "instantaneously created" windward opening in the Texas Technical University (TTU) test building envelope was studied for two different envelope flexibility-leakage combinations namely: (1) a quasi-statically flexible and non-porous envelope and (2) a quasi-statically flexible and porous envelope. The responses forced by creating the openings at different time leads/lags with respect to the occurrence of the peak external pressure showed that for cases where the openings are created in close temporal proximity to the peak pressure, the transient overshoot values of internal pressure could be higher than the peak values of internal pressure in the pre-sequent or subsequent resonant response. In addition, the influence of time taken for opening creation on the level of overshoot was also investigated for the TTU building for the two different envelope characteristics. Non-dimensional overshoot factors are presented for a variety of cavity volume-opening area combinations for (1) buildings with rigid/quasi-statically flexible non-porous envelope, and (2) buildings with rigid/quasi-statically flexible and porous envelope (representing most low rise residential and industrial buildings). While the factors appear slightly on the high side due to conservative assumptions made in the analysis, a careful consideration regarding the implication of the timing and magnitude of such overshoots during strong gusts, in relation to the steady state internal pressure response in cyclonic regions, is warranted.

Characteristics of wind loading on internal surface and its effect on wind-induced responses of a super-large natural-draught cooling tower

  • Zou, Yun-feng;Fu, Zheng-yi;He, Xu-hui;Jing, Hai-quan;Li, Ling-yao;Niu, Hua-wei;Chen, Zheng-qing
    • Wind and Structures
    • /
    • 제29권4호
    • /
    • pp.235-246
    • /
    • 2019
  • Wind loading is one of important loadings that should be considered in the design of large hyperbolic natural-draught cooling towers. Both external and internal surfaces of cooling tower are under the action of wind loading for cooling circulating water. In the previous studies, the wind loads on the external surface attracted concernedly attention, while the study on the internal surface was relatively ware. In the present study, the wind pressure on the internal surface of a 220 m high cooling tower is measured through wind tunnel testing, and the effect of ventilation rate of the packing layer on internal pressure is a major concern. The characteristics of internal wind pressure distribution and its effect on wind-induced responses calculated by finite element method are investigated. The results indicate that the wind loading on internal surface of the cooling tower behaves remarkable three-dimensional effect, and the pressure coefficient varies along both of height and circumferential directions. The non-uniformity is particularly strong during the construction stage. Analysis results of the effect of internal pressure on wind-induced responses show that the size and distribution characteristics of internal pressure will have some influence on wind-induced response, however, the outer pressure plays a dominant role in the wind-induced response of cooling tower, and the contribution of internal pressure to the response is small.

우리나라 제조기업의 환경경영시스템 도입에 대한 영향요인 연구 (The Influence Factors on the Adoption of Environmental Management Systems in Korean Manufacturing Firms)

  • 최종민
    • 경영과학
    • /
    • 제31권2호
    • /
    • pp.15-32
    • /
    • 2014
  • This research empirically investigated the influence factors on the adoption of environmental management systems (EMS) in Korean manufacturing firms. In this study, the external factors (cause factors), the internal factors (facilitating factors) and the firm specific characteristics were integrally considered. In the factor analysis, the third item (regional society) of the external factors and the first item (environmental law) of government regulation were confounded with the items of the other factors. Thus, the confounded items were removed. In the second factor analysis, no items were replicated. The results of a multiple regression analysis showed that the influence factors such as government regulation, normative pressure, top management support, environmental strategy and employees' recognition, and ratio of large shareholders have a significant impact on the construction of EMS. However, the effects of the other firm specific characteristics were not statistically significant. We also examined whether both the number of environmental personnel and the allocation of environmental resources, which are directly related with the adoption of EMS, have a moderating impact on the relationships between other internal factors and the construction of EMS. With a subgroup analysis, the moderating roles of the number of environmental personnel were empirically confirmed. Through a multiple regression analysis, the direct effects of the external factors on the adoption or construction of the internal factors were demonstrated. The effects of government regulation, normative pressure and imitative pressure on the internal factors were significant and positive. Finally, in this study, the fact that the adoption of EMS can improve the environmental performance of a firm was also empirically found.

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • 제4권1호
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

상하운동하는 유압실린더의 제어특성 (Control Characteristics of Fluid Power Cylinder Moving Up and Down)

  • 염만오;윤일로;이석영
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1152-1158
    • /
    • 2004
  • In this study a MRAC(model reference adaptive control) for fluid power elevator model system was designed. The MRAC was compared with PI control in case of applying to the elevator model system with constant external load and changing external load. In this case external load was produced by a single fluid power cylinder combined with pressure control valve. In conclusion the MRAC control performance was better than PI control performance because overshoot and steady state error of the elevator model system controlled by the MRAC were not appeared for constant and changing external load.

해저면에 설치된 2차원 복합해저관로 주위의 유동특성에 관한 실험적 연구 (A Study of Flow Pattern around the Two-Dimensional Dual Subsea Pipeline on Sea Bottom)

  • 나인삼;조철희;정우철;김두홍
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.122-127
    • /
    • 2001
  • As pipelines are often used to transport gas, oil, water and oil products, there are more than one pipeline installed in the offshore field. The size and space of pipelines are various depending on the design specifications. The pipelines are to be designed and installed to secure the stability to external loads during the installation and operation period. The flow patterns are very complex around the pipelines being dependent on incoming flow velocity, pipelines size and space. To investigate the flow patterns, number of experiment are conducted with visualization equipment in a circulating water channel. The flow motion and trajectory were recorded from the laser reflected particles by camera. From the experiment the flow patterns around spaced pipelines were obtained. Also pressure gradient was measured by mano-meter to estimate the hydrodynamic forces on the behind pipeline. The results show that the various sizes and spaces can be affected in the estimation of external load. The complex flow patterns and pressure gradients can be effectively used in the understanding of flow motion and pressure gradient.

  • PDF

국외 천연가스 배관 사고 빈도 비교 및 분석 모형에 관한 연구 (A Study on Failure Frequency Model for Risk Analysis of Natural Gas Pipeline with Comparison of Overseas Failure Data)

  • 오신규
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.60-66
    • /
    • 2014
  • 본 연구에서는 국내 매설 고압가스배관의 사고빈도 데이터 구축 시 활용할 수 있도록 국외에서 발표하고 있는 고압가스배관 사고빈도 데이터에 대해 고찰 하였다. 고압가스배관 사고빈도 데이터의 대표적인 것으로는 미국의 DOT, 유럽의 EGIG 및 영국의 UKOPA가 있다. 국외 사고빈도 데이터의 국내 적용 가능성을 확인하기 위하여 이들을 비교 분석한 결과 EGIG 데이터가 국내 실정에 더 적합하였다. EGIG 8차 보고서의 사고빈도 데이터를 사용하여 비선형회귀분석을 수행한 결과 배관 설치 연도에 따른 지수형의 곡선을 얻었다. 향후 전체 사고빈도의 약 50%를 차지하고 있는 타공사 부분과 국내 데이터와 국외 데이터의 합성에 대한 집중적인 연구가 필요하다.

내외압을 받는 압력용기의 탄소성 해석과 파괴거동에 대한 고찰 (A study on the elastic-plastic analysis and fracture behavior of pressure vessel)

  • 엄동석
    • Journal of Welding and Joining
    • /
    • 제6권2호
    • /
    • pp.19-29
    • /
    • 1988
  • This paper reports on the elatic-plastic analysis and fracture behavior of cylinder with outer surface crack which is under external or internal pressure. For the studuty of crack length effects in cylinder, ratios of crack lengths to finite thickness (a/t) are dertermined 0.3, 0.4, 0.5. For the study of curvature effects in cylinders, ratios of mean diameter to finite thicknees (Rm/t) are determined 10.0, 15.0, 20.0. Analysis is conduceted using the theory of fracture mechanics and two dimensional finite element solution assuming the axi-symmetrical plane strain conditon. Main results of this study are as follows. 1) It is known from this paper that elastic-plastic strain is initiated near crack tip and enlarged between crack tip and inner side of cylinder. 2) $K_{1}$ of cylinder under external or internal pressure is evaluated memebrane stress .root..pi.* crack length. The results of this study are inclined to Lomacky's results and Kobayshi's result. 3) Distribution of stress near crack tip is looked higher than of other zone, as crack length of equal model is longer, and as diameter of cylinder is longer. 4) When other conditions are equal, displacemenet near crack tip is looked duller, as length is longer.

  • PDF