• Title/Summary/Keyword: Exposure dose rate

Search Result 376, Processing Time 0.027 seconds

Comparison of Radioactive Waste Transportation Risk Assessment Using Deterministic and Probabilistic Methods (결정론적 및 확률론적 방법을 이용한 방사성폐기물 운반 위험도 평가 비교·분석 )

  • Min Woo Kwak;Hyeok Jae Kim;Ga Eun Oh;Shin Dong Lee;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.83-92
    • /
    • 2023
  • When assessing the risk of radioactive wastes transportation on land, computer codes such as RADTRAN and RISKIND are used as deterministic methods. Transportation risk assessment using the deterministic method requires a relatively short assessment time. On the other hand, transportation risk assessment using the probabilistic method requires a relatively long assessment time, but produces more reliable results. Therefore, a study is needed to evaluate the exposure dose using a deterministic method that can be evaluated relatively quickly, and to compare and analyze the exposure dose result using a probabilistic method. The purpose of this study is to evaluate the exposure dose during transportation of radioactive wastes using deterministic and probabilistic methods, and to compare and analyze them. For this purpose, the main exposure factors were selected and various exposure situations were set. The distance between the radioactive waste and the receptor, the size of the package, and the speed of vehicle were selected as the main exposure factors. The exposure situation was largely divided into when the radioactive wastes were stationary and when they were passing. And the dose (rate) model of the deterministic overland transportation risk assessment computer code was analyzed. Finally, the deterministic method of the RADTRAN computer code and the RISKIND computer code and the probabilistic method of the MCNP 6 computer code were used to evaluate the exposure dose in various exposure situations during transportation of radioactive wastes. Then we compared and analyzed them. As a result of the evaluation, the tendency of the exposure dose (rate) was similar when the radioactive wastes were stationary and passing. For the same situation, the evaluation results of the RADTRAN computer code were generally more conservative than the results of the RISKIND computer code and the MCNP 6 computer code. The evaluation results of the RISKIND computer code and the MCNP 6 computer code were relatively similar. The results of this study are expected to be used as basic data for establishing the radioactive wastes transportation risk assessment system in Korea in the future.

Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward (방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가)

  • Kang, Seok-Jin;Lee, Doo-Hyeon;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

Survival Rate, Growth and NP Accumulation of the Striped Bitterling, Acheilognathus yamatsutae Long-term Exposed to Nonylphenol (NP) (노닐페놀 (NP)에 장기간 노출된 줄납자루, Acheilognathus yamatsutae의 NP 체내 축적, 성장 및 생존율)

  • Jin, Young-Guk;Kim, Chi-Hong;Lee, Chul-Woo;Lee, Jung-Sick
    • Journal of fish pathology
    • /
    • v.21 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • Striped bitterling, Acheilognathus yamatsutae (TL: 4.25 ㎝, TW: 0.73 g)were exposed to 0.3, 1.3, 17.6 and 33.7 ㎍ L-1 (nominal concentrations) of nonylphenol (NP) for a period of 20 weeks. We studied on accumulation, growth and survival rate. After 20 weeks of exposure, the accumulation of NP in the body of the female and male was increased with increasing dose-dependent and female was higher than male. 4 weeks of exposure, TL of female striped bitterling was found to be increased in all of the dose group compared to control and 12 weeks of exposure, similar or some decreased in all of the dose group compared to control. 20 weeks of exposure, increased in all of the dose group compared to control and TL at 33.7 ㎍ NP L-1 were significantly higher than those in control (p <0.05). 4 weeks of exposure, TL and TW of male striped bitterling was found to be increased in all of the dose group compared to control and significantly higher in TL of 33.7 ㎍ NP L-1 (p <0.05). 12 and 20 weeks of exposure, TL and TW decreased in all of the dose group compared to control and significantly lower in 1.3 ㎍ NP L-1 of 12 weeks. Survival rate in both groups decreased with increasing NP concentration and there was a significant difference between control group and experimental groups exposed to each NP concentration.

A Study on the Environmental Radiation Dose Measurement in the Nuclear Medicine Department (핵의학과에서 환경방사선량 측정에 대한 연구)

  • Kang, Bo-Sun;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2118-2123
    • /
    • 2010
  • Korean individual occupational exposure control is focused on the retrospective service to the over-exposed person by the reading of personal dosimeter. Since the radiophamaceuticals using in the nuclear medicine department are uncontained radiation sources, the potential exposure at working environment is very high. Moreover, a patient remains radioactive for hours or even days after the administration of a radiopharmaceutical for diagnosis or treatment. Thus, the proper working environmental exposure control must be established and executed to protect not only the affiliated employees, but also guardians accompanying patients and temporarily visiting public from the exposure by the patients. Japanese radiation protection law regulates working environmental radiation exposure by regularly measuring and filing the environmental dose for years. This study was aimed at measuring working environmental radiation dose in the nuclear medicine department of an university hospital located in Daejeon, Korea. We measured the accumulation radiation dose in air at 8 locations in the nuclear medicine department by using the same method as in Japan with glass dosimeters. The highest dose rate, 0.23 mSv per month, was measured at the waiting room, and the second one is at reception desk. Even though the doses were lower than the Korean constraint dose rate (0.3 mSv/week) at the boundary of the radiation controlled area, it was over the dose limit of public (1 mSv/y) and environment (0.25 mSv/y). Conclusionally, it was found that the new or additional procedure was necessary to less the exposure dose to the receptionist and guardians by the environmental radiation dose in the nuclear medicine department.

A Study on Retrospective of External Radiation Exposure Dose by Optically Stimulated Luminescence of Smart Chip Card (스마트칩 카드을 이용한 광 자극 발광 특성 연구)

  • Park, Sang-Won;Yoo, Se-Jong
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.379-385
    • /
    • 2019
  • Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can't be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can't be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

Study on the Effectiveness of Radiological Technologist's Thyroid Shielding in Pediatric Paranasal Sinus X-ray Examination (어린이 부비동 엑스선 검사에서 검사자의 갑상선 차폐 효과성에 관한 연구)

  • Chang-Kyo Kwak;Jeong-Taek Kwon;Kwang-Je Lee;Il-Hwan Bae;Hye-Jung Kim;So-Mi Lee;Do-Byung Rhee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.197-203
    • /
    • 2024
  • During paranasal sinus X-ray examinations in children, the radiological technologist's thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist's could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

Development of a Real-Time Active Safety Management Platform and Data Collection Device for the Safety of Radiation Workers (방사선 작업종사자 안전을 위한 실시간 능동형 안전관리 플랫폼과 데이터 수집 디바이스 개발 연구)

  • Kilsoon Park;Kihun Bae;Yongkwon Kim;Won Ki Seo
    • Journal of Radiation Industry
    • /
    • v.18 no.3
    • /
    • pp.209-215
    • /
    • 2024
  • Radiation work always carries the risk of radiation exposure, so regulatory agencies manage it through licensing when high exposure is expected. However, due to passive management methods using TLD, etc., there are cases where risk management is done after an incident occurs or the incident is covered up. In this study, we developed a system to manage the location of radiation work and the risk of workers in real time through a safety management platform and a location-based personal dosimeter. The safety platform server receives data from the developed personal dosimeter in real time and manages risks in three steps for each worker using location and dose rate, and can predict risks and generate alarms in real time. The personal dosimeter transmits the location and dose rate of the worker in real time using GPS and LTE communication. The developed safety management platform and personal dosimeter were verified through a field test to receive real-time data of the location and dose rate data of the worker, and the risk management function according to the individual dose rate was verified.

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

DOSE AND DOSE RATE EFFECTS OF IRRADIATION ON BLOOD COUNT AND CYTOKINE LEVEL IN BALB/c MICE

  • Son, Yeonghoon;Jung, Dong Hyuk;Kim, Sung Dae;Lee, Chang Geun;Yang, Kwangmo;Kim, Joong Sun
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.179-184
    • /
    • 2013
  • The biological effects of radiation are dependent on the dose rate and dose of radiation. In this study, effects of dose and dose rate using whole body radiation on plasma cytokines and blood count from male BALB/c mice were evaluated. We examined the blood and cytokine changes in mice exposed to a low (3.49m Gy $h^{-1}$) and high (2.6 Gy $min^{-1}$) dose rate of radiation at a total dose of 0.5 and 2 Gy, respectively. Blood from mice exposed to radiation were evaluated using cytokine assays and complete blood count. Peripheral lymphocytes and neutrophils decreased in a dose dependent manner following high dose rate radiation. The peripheral lymphocytes population remained unchanged following low dose rate radiation; however, the neutrophils population increased after radiation. The sera from these mice exhibited elevated levels of flt3 ligand and granulocyte-colony-stimulating factor (G-CSF), after high/low dose rate radiation. These results suggest that low-dose-rate radiation does not induce blood damage, which was unlike high-dose-rate radiation treatment; low-dose-rate radiation exposure activated the hematopoiesis through the increase of flt3 ligand and G-CSF.

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF