• 제목/요약/키워드: Exposure Measure

검색결과 573건 처리시간 0.026초

국내 디클로로메탄 제조·사용 사업장 근로자의 공정별 노출수준에 대한 작업환경측정값과 ECETOC TRA 모델값 비교연구 (Comparative Study of Korean Workers' Exposure to Dichloromethane by Process Category between Work Environment Monitoring Program and ECETOC TRA)

  • 정수진;배계완;이나루
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.317-330
    • /
    • 2021
  • Objectives: By law, companies in Korea must periodically measure workers' exposure to harmful chemicals (the system is called the Work Environment Monitoring Program (WMP)[a]) and report the results to the government. The government also measures exposure to monitor the WMP's reliability (called Reliability Assessment (RA) for WMP[b]). The issue is that measured data from these two sources are so different that the objectivity of WMP needs to be confirmed by comparing the results using the European Centre for Ecotoxicology and Toxicology of Chemicals' Targeted Risk Assessment (ECETOC TRA). Methods: Step 1: Data collection from WMP reports submitted by companies (n=586) and RA for WMP written by the government (n=33). Step 2: Data Standardization by key information included. Step 3: Data conversion to input-variables required to run the ECETOC TRA model, and run the model with specific data (n=514) which meet the predetermined exposure scenario. Step 4: Statistical data analysis by process category (PROC) and ventilation type from each source ([A] and [B]). Step 5: Additional analysis of any unexpected results. Results: The process categories of the production and handling of Dichloromethane were classified into 12 PROCs, and ten of them were selected to run ECETOC TRA. Modeled values tended to be higher than measured values from both sources. For the measured values from WMP, RCR distribution by PROC was narrow (0.197-0.267, 95% CI) and did not have a relationship with ventilation type, which differs from the tendency of the modeling result. Meanwhile, the measured values from RA for WMP were relatively widely distributed (0.301-1.177, 95% CI) by PROC. In particular PROCs (13,19) were high enough to exceed 1. Also, they become low with better ventilation types and appear differently depending on the ventilation type, similar to the model result. Conclusions: This study revealed that ECETOC TRA might have the potential to serve as a screening tool for exposure assessment and to be used as assistive method for WMP to estimate exposure. Further empirical study is required to confirm its availability as a screening tool.

건식 저장방식별 사용후핵연료 운반 작업자 피폭시나리오 개발 (Development of Spent Nuclear Fuel Transportation Worker Exposure Scenario by Dry Storage Methods)

  • 손건우;김혁재;이신동;곽민우;김광표
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.43-52
    • /
    • 2024
  • Currently, there are no interim storage facilities and permanent disposal facilities in Korea, so all spent nuclear fuels are temporarily stored. However, the temporary storage facility is approaching saturation, and as a measure to this, the 2nd Basic Plan for the Management of High-Level Radioactive Waste presented an operation plan for dry interim storage facilities and dry temporary storage facilities on the NPP on-site. The dry storage can be operated in various ways, and to select the optimal dry storage method, the reduction of exposure for workers must be considered. Accordingly, it is necessary to develop a worker exposure scenario according to the dry storage method and evaluate and compare the radiological impact for each method. The purpose of this study is to develop an exposure scenario for workers transporting spent nuclear fuel by dry storage method. To this end, first, the operation procedure of the foreign commercial spent nuclear fuel dry storage system was analyzed based on the Final Safety Analysis Report (FSAR). 1) the concrete overpack-based system, 2) the metal overpack-based system, and 3) the vertical storage module-based system were selected for analysis. Factors were assumed that could affect the type of work (working distance, working hours, number of workers, etc.) during transportation work. Finally, the work type of the processes involved in transporting spent nuclear fuel by dry storage method was set, and an exposure scenario was developed accordingly. The concrete overpack method, the metal overpack method, and the vertical storage module method were classified into a total of 31, 9, and 23 processes, respectively. The work distance, work time, and number of workers for each process were set. The product of working hours and number of workers (Man-hour) was set high in the order of concrete overpack method, vertical storage module method, and metal overpack method, and short-range work (10 cm) was most often applied to the concrete overpack method. The results of this study are expected to be used as basic data for performing radiological comparisons of transport workers by dry storage method of spent nuclear fuel.

Digora$\textregistered$에서 정량영상의 특성에 대한 평가 (The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$)

  • 김재덕
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

프리즘과 광섬유-평면도파로의 소산장 결합을 이용한 자외선 센서 (UV Sensor using Evanescent Field Coupling of Prism and Fiber-to-Planar Waveguide Coupler)

  • 조강민;윤정현;김응수;이승하;강신원
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.350-355
    • /
    • 2004
  • A novel UV sensor was manufactured and characterized using the evanescentfield coupling between fiber-planar waveguide (PWG) coupler and prism. A spiroxazine dye was chosen as planar waveguide because its photochromic isomerization induced by UV irradiation. A novel UV sensor was proposed to measure the variation of refractive index and absorption coefficient simultaneously. The wavelength responses of these sensors by UV exposure times were measured 0.48 nm/sec, 0.757 nm/sec, and ATR output power variations were measured $-0.424{\mu}W$/sec and $-0.62{\mu}W$/sec when UV exposure power were 3 mW and 5 mW, respectively.

Application of the new ICRP iodine biokinetic model for internal dosimetry in case of thyroid blocking

  • Kwon, Tae-Eun;Chung, Yoonsun;Ha, Wi-Ho;Jin, Young Woo
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1826-1833
    • /
    • 2020
  • Administration of stable iodine has been considered a best measure to protect the thyroid from internal irradiation by radioiodine intake, and its efficacy on thyroid protection has been quantitatively evaluated in several simulation studies on the basis of simple iodine biokinetic models (i.e., three-compartment model). However, the new iodine biokinetic model adopted by the International Commission on Radiological Protection interprets and expresses the thyroid blocking phenomenon differently. Therefore, in this study, the new model was analyzed in terms of thyroid blocking and implemented to reassess the protective effects and to produce dosimetric data. The biokinetic model calculation was performed using computation modules developed by authors, and the results were compared with those of experimental data and prior simulation studies. The new model predicted protective effects that were generally consistent with those of experimental data, except for those in the range of stable iodine administration -72 h before radioiodine exposure. Additionally, the dosimetric data calculated in this study demonstrates a critical limitation of the three-compartment model in predicting bioassay functions, and indicated that dose assessment 1 d after exposure would result in a similar dose estimate irrespective of the administration time of stable iodine.

일 제조업체의 작업장 소음실태에 관한 연구 (A Study on Actual Condition of the Noise in a Factory)

  • 신수옥
    • 한국보건간호학회지
    • /
    • 제9권2호
    • /
    • pp.43-51
    • /
    • 1995
  • Many poeple has been engaged in industry is aware of the dangers from exposure to high intensity nose levels. The exposure to high intensity noise is encountered in a large number of situations. Laws governing the safety and health of employed people being to create a suitable working environment and eliminate unsafety practices and processes. Work areas should be designed and laid out so that they are satisfactory both from the environmental and safety points of view. In this connection safety also implies that noise is kept at a level which is not likety to cause hearing damage. This study was performed to measure the noise of press and assembly process in an automobile factory. and suggested the method of noise control. Consequently the effect ways of reducing level in working environment are as follows; 1. Changes to machines which would reduce noise generation. 2. Alteration of equipment to avoid impact in machinery and handing materials. 3. Enclosure of noisy machines or machine parts. 4. Mounting of attenuators on gas and air outlets as well as ventilation ducts. 5. Erection of sound absorbing screens. linings. and baffles in work areas. 6. The personal ear protectors can be chosen to protect the workers.

  • PDF

Simple power analysis in causal mediation models for a dichotomous outcome based on the mediation proportion

  • Kim, Young Min;Cologne, John Bennett;Cullings, Harry Michael
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권3호
    • /
    • pp.669-684
    • /
    • 2017
  • Mediation models are widely used in many fields of research and have recently gained attention in epidemiology. The mediation proportion is a standard measure to evaluate what part of the total exposure effect on an outcome may be explained by a particular mediator and to examine how important that pathway is relative to the overall exposure effect. A common question is how large a sample size is needed to achieve high statistical power or, equivalently, what magnitude of effect can be detected. Current power and sample size calculations for mediation analysis are limited and additional research is needed. We therefore propose a computer-intensive power analysis using the mediation proportion. We conduct simulation studies to calculate statistical powers and sample sizes. And then, we illustrate our power analysis using an example from the Adult Health Study of atomic-bomb survivors and demonstrate that the method is relatively straightforward to understand and compute.

BOES CCD 카메라 II. 카메라의 특성 (THE BOES CCD CAMERA II. CHARACTERISTICS OF THE CCD)

  • 박병곤;성현철;장정균;장비호;이병철;박윤호;김강민;한인우
    • 천문학논총
    • /
    • 제18권1호
    • /
    • pp.75-79
    • /
    • 2003
  • The characteristics of the BOES (Bohyunsan Observatory Echelle Spectrograph) CCD camera is presented. In order to get optimum gain and readout noise of the CCD, we examine the variation of the gain and readout noise by changing the value of output drain voltage of the CCD and measuring the gain using transfer curve, which is defined as the plot of variance versus mean exposure level of a homogeneous light onto the CCD surface. The gain and readout noises are optimised to be 0.5e$^-$/ADU and 3e$^-$, which is good for highest signal-to-noise ratio and contrast for the low light level characteristics of the BOES. We also measure the dark count of the CCD by getting five dark images with 3600 seconds exposure time. The mean dark count from median stacked dark images is essentially zero. A table of positions of defected pixels is also presented.

가시광선(可視光線) 복합(復合)레진의 심부경도(深部硬度) 측정(測定)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON HARDNESS IN VISIBLE LIGHT-CURED COMPOSITE RESIN AT VARYING DEPTH)

  • 명재근;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제11권1호
    • /
    • pp.43-52
    • /
    • 1985
  • The purpose of this study was to measure the Micro-Knoop Hardness of three commercial visible light-cured composite resins (Plurafil-super, He1iosit and Durafi) according to the difference of depth and shade. Specimens of the resin were prepapared in plastic tubes 5mm in diameter with height of 5mm, and the tubes were put into the columned holes in stone molds. The molds were exposed to the visible light through the hole 5mm in diameter in metal plate. Specimens were sectioned (longitudinally) with disk. Knoop Hardness measurements were made at the depth of surface, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0mm from the surface to the deep portion. Knoop Hardness numbers were taken on each depth under 20gm load for 10 seconds with Shimadzu Tester. The following results were: 1. The highest hardness value was measured at 0.5mm depth. Then the deeper the depth, the lesser the hardness was observed. 2. The value of hardness was directly propotional to the time of exposure to the light. 3. The hardness of light shade resin was higher than the that of the dark shade. 4. The pattern of hardness change at varying depth is similar to all the experimental materials with no relation to the shade nor exposure time.

  • PDF