• Title/Summary/Keyword: Exposure Device

Search Result 429, Processing Time 0.025 seconds

A Design of Temperature Management System for Preventing High Temperature Failures on Mobility Dedicated Storage (모빌리티 전용 저장장치의 고온 고장 방지를 위한 온도 관리 시스템 설계)

  • Hyun-Seob Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.125-130
    • /
    • 2024
  • With the rapid growth of mobility technology, the industrial sector is demanding storage devices that can reliably process data from various equipment and sensors in vehicles. NAND flash memory is being utilized as a storage device in mobility environments because it has the advantages of low power and fast data processing speed as well as strong external shock resistance. However, flash memory is characterized by data corruption due to long-term exposure to high temperatures. Therefore, a dedicated system for temperature management is required in mobility environments where high temperature exposure due to weather or external heat sources such as solar radiation is frequent. This paper designs a dedicated temperature management system for managing storage device temperature in a mobility environment. The designed temperature management system is a hybrid of traditional air cooling and water cooling technologies. The cooling method is designed to operate adaptively according to the temperature of the storage device, and it is designed not to operate when the temperature step is low to improve energy efficiency. Finally, experiments were conducted to analyze the temperature difference between each cooling method and different heat dissipation materials, proving that the temperature management policy is effective in maintaining performance.

A STUDY ON THE SCATTER RADIATION AFFECTING THE DENTAL X-RAY FILM (산란 방사선이 치과용 방사선 필름에 미치는 영향에 관한 연구)

  • Park Eung Chun;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of scatter radiation to dental x-ray film with long time-exposure in the different structures of the tooth, by using pinhole camera. For this study, pinhole camera, skull with tooth, and pocket dosimeter were used. The radiation with 70 and 90kVp and exposure time (minimum: 2.5 min., maximum 10 hrs.) was projected to the film in the pinhole camera. And density of the obtained x-ray film was measured with densitometer. In the intra-oral film taking, the amount of exposure of the scatter radiation affecting the thyroid gland area was measured with the dosimeter at the thyroid gland. The density of radiographs was compared in radiation projected with or without the metal cone of dental machine. The effect of the back scatter radiation to the film was also evaluated when the lead foil was removed. The obtained results were as follows: 1. A pinhole camera was a valuable device for locating the source of x-ray. 2. The scatter radiation affected the dental x-ray film when the radiation source was exposed. more than 5 hours'. In that case, the density of the scatter radiation could be observed visually. 3. The scatter radiation caused by short exposure of dental radiation didn't affect the diagnostic quality of the dental x-ray film. 4. The differences of densities between the tooth and the soft tissue according to exposure time showed 0.16 in 5 hours' exposure & 0.17 in 10 hours' exposure at 70 kVp & 0.12 in 5 hours' exposure & 0.13 in 10 hours' exposure at the 90kVp. 5. The differences of densities between the tooth and the soft tissue according to kVp showed no difference between 5 hours' exposure of tooth at 70 kVp and soft tissue at 90 kVp, but showed 0.05 high density in tooth when 10 hours' exposure at 90 kVp. 6. No difference of density was on radiographs taken with or without dental machine cone. 7. Back scatter radiation was recorded image of radiographs for only 3 min. 8. The amounts of the scatter radiation exposed to the thyroid gland in intraoral film taking were 1.12 mr in upper anterior, 0.55 mr in upper posterior, 2.75 mr in lower anterior, and 1.92 mr in lower posterior teeth.

  • PDF

Auto Exposure Control System using Variable Time Constants (가변 시상수를 이용한 자동 노출제어 시스템)

  • Kim, Hyun-Sik;Lee, Sung-Mok;Jang, Won-Woo;Ha, Joo-Young;Kim, Joo-Hyun;Kang, Bong-Soon;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2007
  • In order to obtain a fine picture, a camera has many convenient functions. Its representative functions are Auto Focus(AF), Auto White Balance(AWB) and Auto Exposure(AE). In this paper, we present the new algorithm of Auto Exposure control system, one of its useful functions The proposed algorithm of Auto Exposure control system is based on IIR Filter with Variable Time Constant. First, in order to establish the standards of exposure control, we compare change of the picture luminance with luminance of an object in the Zone system. Second, we make an ideal characteristic graph of luminance by using the results. Finally, we can find the value of the right exposure by comparing an ideal characteristic graph of the luminance with the value of the current expose of a scene. We can find an appropriate exposure as comparing the ideal characteristic graph of the luminance with current exposure of a scene. In order to find a suitable exposure state, we make use of IIR Filter instead of a conventional method using micro-controller. In this paper, the proposed system has therefore simple structure, we use it for compact image sensor module used in the handheld device.

Information Types and Display Methods according to the Relation between Frequency of Exposure and Degree of Cognition (노출빈도와 인지도 관계에 따른 정보의 유형과 표현기법)

  • Han, Ji-Ae;You, Si-Cheon
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.497-504
    • /
    • 2012
  • Information types and display methods according to the relation between frequency of exposure and degree of cognition was suggested by this study as a way to enhance effective communication by information in aspect of user cognition. First of all, we ascertained the relation between frequency of exposure and degree of cognition by literature research for cognitive psychology and cognitive engineering psychology, results are as follows based in it. First, we suggested information types and attributes for visualization as 'Framework' which helps designers understand cognitive demands of users. Specifically, there are 4 types(STM, STA, LTM, LTA) of information according to the relation between frequency of exposure and degree of cognition, cognitive characteristics for each types and 'attributes matrix for visualization' which is consisted of 14 attributes of high -quality information and resorted by the types. Second, we suggested a guideline for display methods according to depth of information in the design process of information contents. For display methods of STM, STA information as primary information, we suggested "Attribution theory of Distinctiveness", "Advance Organizer", "Progress Closure", "Affordance", for display methods of LTM information as multidimensional information, we suggested "Modularity", "Consistency", "Mimicry", "Mnemonic Device". We had found from this study that there are distinction of status for attributes of information visualization according to information types or depth, and various display methods by them.

A Design of DA_UDC(Double Authentication User.Device.Cross) Module using OTA(One Time Authentication) Key in Home Network Environment (홈 네트워크 환경에서 OTA(One Time Authentication)키를 이용한 DA_UDC(Double Authentication User.Device.Cross) 모듈 설계)

  • Jeong, Eun-Hee;Lee, Byung-Kwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4B
    • /
    • pp.419-427
    • /
    • 2009
  • This paper propose DA-UDC(Double Authentication User, Device, Cross) Module which solves the cost problem and the appropriation of Certificate using User Authentication, Device Authentication and Cross Authentication with OTA(One Time Authentication) Key, and which is designed not to subscribe to the service of Home network business. Home Server transmits its public key which is needed to create OTA to the user which passed the first step of authentication which verifies User ID, Device ID and Session Key. And it performs the second step of authentication process which verifies the OTA key created by a user. Whenever the OTA key of DA-UDC module is generated, the key is designed to be changed. Therefore, DA-UDC Module prevents the exposure of User and Device ID by performing the two steps of authentication and enhances the authentication security of Home Network from malicious user with OTA key. Also, DA-UDC Module is faster than the existing authentication system in processing speed because it performs authentication calculation only once. Though DA-UDC Module increases data traffic slightly because of the extra authentication key, it enhances the security more than the existing technique.

Development of Wearable Device for Monitoring Working Environment in Pig House (양돈장 작업환경 모니터링을 위한 웨어러블 장비개발)

  • Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.71-81
    • /
    • 2020
  • Enclosed pig house are creating an environment with high concentrations of gas and dust. Poor conditions in pig farms reduce pig weight and increase disease and accidents for livestock workers. In the pig house, the high concentration of harmful gas may cause asphyxiation accidents to workers and chronic respiratory disease by long-term exposure. As pig farm workers have been aging and feminized, the damage to the health of the harsh environment is getting serious, and real-time monitoring is needed to prevent the damage. However, most of the measuring devices related to humidity, harmful gas, and fine dust except temperature sensors are exposed to high concentrations of gas and dust inside pig house and are difficult to withstand for a long time. The purpose of this study is to develop an wearable based device to monitor the hazardous environment exposed to workers working in pig farms. Based on the field monitoring and previous researches, the measurement range and basic specifications of the equipment were selected, and wearable based device was designed in terms of utilization, economic efficiency, size and communication performance. Selected H2S and NH3 sensors showed the average error of 5.3% comparing to standard gas concentrations. The measured data can be used to manage the working environment according to the worker's location and to obtain basic data for work safety warning.

Analysis and Isolation of Walking-type Cultivator Vibration Transmitted to Operator′s Hands (손으로 전달된 관리기 진동의 분석과 방진대책)

  • 박영준;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • This study was intended to measure and analyze hand-transmitted vibrations from cultivator in idle and operation modes for three different types of field works. Based on this analysis a time for the white finger syndrome to appear on 10% of the operators was estimated assuming that their daily exposure is 3 hours. The 4 methods to reduce the hand vibration were also proposed and compared with each other. The results of the study were summarized as follows : The highest vibration level was recorded during trenching operation, resulting in a total average vibration of 11.5 m/s$^2$. Followings were 7.6 m/s$^2$ during rotary tillage and 7.0 m/s$^2$ for weeding. When exposed to these levels of vibrations three hours a day, the white finger syndrome is likely to appear in 4 years for trenching, 6.2 years for rotary tillage and 6.8 years for weeding operations. Isolation of hand vibration performed by a rubber pad, anti-vibration gloves, a handle anti-vibration device and engine mounts were respectively 15.7%, 16.5%. 26.1% and 27.0%, resulting in most effective methods of the handle anti-vibration device and engine mounts. A better performance of about 33.9% was achieved when both the handle anti-vibration device and engine mounts were used.

Development of wrinkled skin-on-a-chip (WSOC) by cyclic uniaxial stretching

  • Lim, Ho Yeong;Kim, Jaewon;Song, Hyun Jeong;Kim, Kyunghee;Choi, Kyung Chan;Park, Sungsu;Sung, Gun Yong
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.238-245
    • /
    • 2018
  • The skin experiences constant physical stimuli, such as stretching. Exposure to excessive physical stimuli stresses the skin and can accelerate aging. In this study, we applied a method that allowed human fibroblasts and keratinocytes to be perfused with media to form 3D skin equivalents that were then uniaxially 10%-stretched for 12 h per day (at either 0.01 or 0.05 Hz) for up to 7 days to form wrinkled skin-on-a-chip (WSOC). There was more wrinkling seen in skin equivalents under 0.01 Hz uniaxial stretching than there was for non-stretched skin equivalents. At 0.05 Hz, the stratum corneum almost disappeared from the skin equivalents, indicating that stretching was harmful for the epidermis. At both frequencies, the production of collagen and related proteins in the skin equivalents, such as fibronectin 10 and keratin, decreased more than those in the non-stretched equivalents, indicating that the dermis also suffered from the repeated tensile stress. These results suggest that WSOCs can be used to examine skin aging and as an in vitro tool to evaluate the efficacy of anti-wrinkle cosmetics and medicines.

Simple and Cost-Effective Method for Edge Bead Removal by Using a Taping Method

  • Park, Hyeoung Woo;Kim, H.J.;Roh, Ji Hyoung;Choi, Jong-Kyun;Cha, Kyoung-Rae
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1473-1478
    • /
    • 2018
  • In this study, we have developed a simple and cost-effective method to prevent edge bead formation by covering the edge of a chip-level substrate with heat-resistant tape during patterning using SU-8. Edge beads are a fundamental problem in photoresists and are particularly notable in high-viscosity fluids and thick coatings. Edge beads can give rise to an air gap between the substrate and the patterning mask during UV exposure, which results in non-uniform patterns. Furthermore, the sample may break since the edge bead is in contact with the mask. In particular, the SU-8 coating thickness of the chip-level substrates used in MEMS or BioMEMS may not be properly controlled because of the presence of edge beads. The proposed method to solve the edge bead problem can be easily and economically utilized without the need for a special device or chemicals. This method is simple and prevents edge bead formation on the sample substrate. Despite the small loss in the taping area, the uniformity of the SU-8 coating is improved from 50.9% to 5.6%.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.