X선자동노출(X線自動露出) 제어장치(制御裝置)에 관한 검토(檢討) (Evaluation of Automatic Exposure Control Systems)

  • 김정민;김건중;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권1호
    • /
    • pp.23-28
    • /
    • 1991
  • Automatic exposure control systems are now readily available and widly used in radiography. A device that automatically determines the amount of radiation required to produce an acceptable level of film blackness is called a phototimer, or automatic exposure control. There are limitations in the use of phototimers ; however, equipment can be used much more effectively if one recognize these limitations, and the goal of obtaining a properly exposed, reproducible radiography can be achieved. We have some results in this experimental study. The variations of film density due to kVp are in propotion to below 80 kVp range. But indicate constant level above 80 kVp to 120 kVp. The characteristic density variation by phantom thickness shows the higher the thiner in exit type. AEC system have a density control that is designed to make adjustments increase or decreas the density 10% per step or 25% per step. The automatic exposure control circuits must meet the several regulations of the HEW. Some forms of technique chart is recomened for use of AEC.

  • PDF

CCD 카메라를 이용한 전자빔 조사량의 예측 (Estimation of Electron Dose Rate using CCD Camera)

  • 김진규;김영민;김윤중;이상희;홍기민;오상호
    • Applied Microscopy
    • /
    • 제39권1호
    • /
    • pp.79-83
    • /
    • 2009
  • We report a useful method to estimate the electron dose rate which may be a decisive factor to characterize sample properties. Even though most mircoscopes have their own exposure meters, there are several practical concerns when such exposure meters are used to measure the electron dose rate: 1) Specimen should be avoided within the entire area of exposure meter; 2) beam current has to be always recorded whenever the operation mode is changed; 3) the electron dose rate can not be calculated for the beam current beyond the detectable range. To overcome these limitations, we suggest a useful method which utilize a CCD (charge coupled device) camera which is now a popular detector to obtain the final electron micrographs. We have evaluated the CCD sensitivity using the linear relationship between electron current on the exposure meter and counter ratio on the CCD camera which are built in KBSI-HVEM (high voltage electron microscope). Applying the new method, we obtained the CCD sensitivity which are approximately 0.039 counts/$e^-$ and 1.37 counts/$e^-$ for the Top-TV and the HV-GIF CCD cameras, respectively.

진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구 (A Study on the Development of High-sensitivity AEC-sensor for Minimization of Dose Creep in Diagnostic Imaging System)

  • 김교태;한무재;허예지;김주희;강상식;박지군;남상희
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.321-325
    • /
    • 2016
  • 선량 크리프는 임상적 오류 중 하나로 검사자의 미숙 또는 부주의에 기인하여 발생하는 현상으로 AAPM Task Group #116에 의하면 디지털 방식의 시스템에서 지속적인 발생이 보고되고 있다. 이러한 현시점에서 선량 크리프 현상을 최소화할 뿐만 아니라 재현성 향상이 가능한 자동노출제어장치의 요구가 증가하고 있다. 이에 본 연구에서는 제작이 쉬울 뿐만 아니라 고효율 반도체 센서에 대한 연구를 수행함으로써 선량 크리프 현상을 저감할 수 있는 자동노출제어장치의 센서에 대하여 고찰하고자 하였다. 연구 수행 결과, 제작된 I형 센서 및 PIN형 센서의 경우 Ref 센서와 비교하면 광학적 특성이 우수하여 음영효과가 적게 나타날 것으로 사료되고, 대체로 낮은 민감도 특성이 나타나지만, 조사 조건 변화에 따른 일정한 추세를 가짐으로써 정확한 피드백 신호를 자동노출제어장치에 제공할 수 있을 것으로 사료된다.

소음 노출 남성근로자에서 청력 역치의 비대칭성과 관련요인 (Asymmetrical Hearing Loss and Related Factors Among the Noise Exposed Male Workers)

  • 이남수;이경재;김주자
    • 한국산업보건학회지
    • /
    • 제20권2호
    • /
    • pp.94-101
    • /
    • 2010
  • This study was performed to examine the asymmetry of hearing loss among the noise exposed male workers. Findings of otoscopic examination, pure tone audiometry and tympanometry were evaluated for 179 male workers working in the noise exposed workplace. And also selfadministered structured questionnaires were used for each worker's work-related and general characteristics including personal health behaviors. There were significant differences of hearing threshold between right and left ears at 1,000 Hz and 3,000 Hz(p<0.05). And also significant differences of hearing threshold were noted in the age group over 50 at 3,000 Hz, the high risk drinking group either at 3,000 Hz and 4,000 Hz, the work duration group 10-19 years at 3,000 Hz, the noise exposure group under 90 dB(A) at 3,000 Hz, the noise exposure group over 90 dB(A) at 1,000 Hz, the non-wearing protective device group at 4,000 Hz, and the wearing protective device group at 3,000 Hz(p<0.05). Further study is needed to explore the extent and the related factors of the asymmetry of hearing loss in the general population and occupationally noise exposed group.

Effects of 60-Hz Time-Varying Electric Fields on DNA Damage and Cell Viability Support Negligible Genotoxicity of the Electric Fields

  • Yoon, Yeo Jun;Li, Gen;Kim, Gyoo Cheon;Lee, Hae June;Song, Kiwon
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.134-141
    • /
    • 2015
  • The effect of a 60 Hz time-varying electric field was studied using a facing-electrode device (FED) and a coplanar-electrode device (CED) for further investigation of the genotoxicity of 60 Hz time-varying magnetic field (MF) from preceding research. Neither a single 30-minute exposure to the CED or to the FED had any obvious biological effects such as DNA double strand break (DSB) and apoptosis in cancerous SCC25, and HeLa cells, normal primary fibroblast IMR90 cells, while exposures of 60 Hz time-varying MF led to DNA damage with induced electric fields much smaller than those used in this experiment. Nor did repetitive exposures of three days or a continuous exposure of up to 144 hours with the CED induce any DNA damage or apoptosis in either HeLa or IMR90 cells. These results imply that the solitary electric field produced by time-varying MF is not a major cause of DSBs or apoptosis in cancer or normal cells.

골밀도검사에서 피검자의 장기선량 측정 및 차폐기구의 효용성 평가 (Evaluation of the Effectiveness of the Shielding Device and the Organ Dose of Subject During Bone Mineral Density)

  • 조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.187-194
    • /
    • 2020
  • Bone mineral density is a examination to measure the amount of bone in patients with metabolic bone disease. It is a low dose, but may cause unnecessary exposure to the gonads and other organs located in the periphery when examining the lumbar and proximal femurs. Therefore, the purpose of this study was to evaluated the exposure dose for each organ exposed during the bone mineral density through simulation, and analyzed the applicability of the subject to radiation shielding devices using 3D printing materials. As a result, the highest dose was shown at 11.47 uSv in the breast during lumbar examination and 8.98 uSv in the testis during proximal femur examination. Also, the farther away from the examination site, the lower the effect of the scattering-ray. The shielding effect of using 3D printing shielding device showed high results in proportion to the effective atomic number and specific gravity of the printing material. Among the printing materials, ABS + W showed an effect of at least 78.72 to 96.3 9% compared to the existing lead material.

미세 3차원 구조물 제조를 위한 디지털 마이크로미러소자 응용 마이크로 광조형 (Digital Micromirror Device Based Microstereolithography for the Fabrication of 3D Microstructures)

  • 주재영;김성훈;정성호
    • 한국레이저가공학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2006
  • In order to increase the productivity of conventional microstereolithography (MSL), digital micromirror device($DMD^{TM}$) based MSL is proposed and the feasibility of 3D rnicrocomponents fabrication is demonstrated in two ways; free surface and constrained surface techniques. The clearness of optical images at the exposure plane was confirmed for the fabrication of an accurate 3D structure by controlling the dynamic viscosity of FA1260T and the shape accuracy of a structure fabricated with epoxy-based resin ($Somos^{\circledR}$ 10120) was analyzed to determine the optimum curing conditions. After finding the appropriate process variables, the feasibility of multiple microstructures is then demonstrated. Due to the high productivity, MSL using $DMD^{TM}$ showed the potential to replace the existing focused laser beam MSL.

  • PDF

압력조건을 고려한 콘크리트의 염화물이온 침투 장치 개발 (Development of Chloride-ion Penetration Device for Concrete Considering Pressure Condition)

  • 김경태;김규용;이상규;황의철;손민재;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.25-26
    • /
    • 2018
  • In this study, the device was developed for evaluating the effect of pressure on chloride ion penetration of concrete. And chloride-ion penetration depth and water soluble chloride contents was evaluated concrete using ordinary portland cement and blast-furnace slag cement using developed device. As a result, chloride ion penetration of concrete was promoted according to the action of pressure and the exposure period. and the incorporation of blast-furnace slag was effective for chloride attack resistibility under pressure.

  • PDF

SiNx 박막에 의한 OLED 소자의 보호막 특성 (Passivation Properties of SiNx Thin Film for OLEO Device)

  • 주성후
    • 한국전기전자재료학회논문지
    • /
    • 제19권8호
    • /
    • pp.758-763
    • /
    • 2006
  • We has been studied the thin film encapsulation effect for organic light-emitting diodes (OLED). To evaluate the passivation properties of the passivation layer materials, we have carried out the fabrication of green light emitting diodes with ultra violet(UV) light absorbing polymer resin, $SiO_2,\;and\;SiN_x$, respectively. From the measurement results of shrinkage properties according to the exposure time to the atmosphere, we found that $SiN_x$ thin film is the best material for passivation layer. We have investigated the emission efficiency and life time of OLED device using the package structure of $OLED/SiN_x/polymer$ resin/Al/polymer resin. The emission efficiency of this OLED device was 13 lm/W and life time was about 2,000 hours, which reach 95 % of the performance for the OLED encapsulated with metal.