• Title/Summary/Keyword: Explicit method

Search Result 1,022, Processing Time 0.029 seconds

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Numerical Analysis for Consolidation of Compressible Soils (압축성 모의 압밀에 대한 수치해석 -다층토를 중심으로-)

  • Kim, Pal-Gyu;Song, Yong-Hui;Lee, Hwan-Gi
    • Geotechnical Engineering
    • /
    • v.1 no.1
    • /
    • pp.5-12
    • /
    • 1985
  • Ocassionally it is used for simple extensions of Terzahgi's theory to account for time-depend- tint loading but there is little evidence of application in more complicated consolidation theories that take into account such effects as nonlinear stress.strain, layered systems or large strains. The purpose of this paper provides an efficient computer algorthm based on numerical analysis using finite difference method which account for multi-layered soils to determine the degree of consolidation and excess pore pressures relative to time and positions more realistically. The explicitly scheme of solving the consolidation equations has been investigated from the point of view of the stability conditions and the convergence with variance of the operator as well as to obtain an optimal divided depth ratios of total depth. A comparison of the settlement predictions with both the classical analysis and the algorithm based on numerical analysis indicates that the new algorithm scheme is found to be superior to the classical theory in the layered soils.

  • PDF

Shrinkage Structure of Ridge Partial Least Squares Regression

  • Kim, Jong-Duk
    • Journal of the Korean Data and Information Science Society
    • /
    • v.18 no.2
    • /
    • pp.327-344
    • /
    • 2007
  • Ridge partial least squares regression (RPLS) is a regression method which can be obtained by combining ridge regression and partial least squares regression and is intended to provide better predictive ability and less sensitive to overfitting. In this paper, explicit expressions for the shrinkage factor of RPLS are developed. The structure of the shrinkage factor is explored and compared with those of other biased regression methods, such as ridge regression, principal component regression, ridge principal component regression, and partial least squares regression using a near infrared data set.

  • PDF

Access Control of XML Documents using Predictable Flags (예측성 플래그를 이용한 XML 문서의 접근통제 기법)

  • Son, Tae-Yong;Lee, Jong-Hak
    • Journal of Information Technology and Architecture
    • /
    • v.11 no.3
    • /
    • pp.321-332
    • /
    • 2014
  • In this paper we propose a new notion of predictable flags type of authorization for controlling access to XML documents. By using predictable flags, we are able to efficiently detect conflicts between existing authorizations and new authorizations to be added. XML documents have an element-composition hierarchical structure in that a higher level element consists of multiple lower level sub-elements. Many XML documents systems have used the notion of implicit authorization that grants authorizations to an element and the all descendants to avoid the overhead caused by explicitly storing all authorization for each element. When we grant an authorization on an element in the XML documents, the implicit authorization method is inefficient in determining the conflicts since it needs to examine all authorizations on the descendants of that element. In contrast, our mechanism using predictable flags has the advantage of detecting the conflicts immediately at the element where an explicit authorization is to be granted.

Effects of Noise on Indoor Thermal Sensation and Comfort (소음이 실내 온열감과 온열쾌적감에 미치는 영향)

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.83-89
    • /
    • 2017
  • Purpose: Thermal sensation or thermal comfort was randomly used in many studies which focused on combined effects of thermal and acoustic environments on human perception. However, thermal sensation and thermal comfort are not synonyms. Thermal comfort is more complex human perception on thermal environment than thermal sensation. This study aims to investigate effects of noise on thermal sensation and thermal comfort separately, and also to investigate effects of temperature on acoustic sensation and comfort. Method: Combined thermal and acoustic configurations were simulated in an indoor environmental chamber. Twenty four participants were exposed to two types of noise (fan and babble) with two noise levels (45 dBA and 60 dBA) for an hour in each thermal condition of PMV-1.53, 0.03, 1.53, 1.83, respectively. Temperature sensation, temperature preference, thermal comfort, noisiness, loudness, annoyance, acoustic comfort, indoor environmental comfort were evaluated in each combined environmental condition. Result: Noise did not affected thermal sensation, but thermal comfort significantly. Temperature had an effect on acoustic comfort significantly, but no effect on noisiness and loudness in overall data analysis. More explicit interactions between thermal condition and noise perception showed only with the noise level of 60 dBA. Impacts of both thermal comfort and acoustic comfort on the indoor environmental comfort were analyzed. In adverse thermal environments, thermal comfort had more impact than acoustic comfort on indoor environmental comfort, and in neutral thermal environments, acoustic comfort had more important than thermal comfort.

Assessing Reliability of Medical Record Reviews for the Detection of Hospital Adverse Events

  • Ock, Minsu;Lee, Sang-il;Jo, Min-Woo;Lee, Jin Yong;Kim, Seon-Ha
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.5
    • /
    • pp.239-248
    • /
    • 2015
  • Objectives: The purpose of this study was to assess the inter-rater reliability and intra-rater reliability of medical record review for the detection of hospital adverse events. Methods: We conducted two stages retrospective medical records review of a random sample of 96 patients from one acute-care general hospital. The first stage was an explicit patient record review by two nurses to detect the presence of 41 screening criteria (SC). The second stage was an implicit structured review by two physicians to identify the occurrence of adverse events from the positive cases on the SC. The inter-rater reliability of two nurses and that of two physicians were assessed. The intra-rater reliability was also evaluated by using test-retest method at approximately two weeks later. Results: In 84.2% of the patient medical records, the nurses agreed as to the necessity for the second stage review (kappa, 0.68; 95% confidence interval [CI], 0.54 to 0.83). In 93.0% of the patient medical records screened by nurses, the physicians agreed about the absence or presence of adverse events (kappa, 0.71; 95% CI, 0.44 to 0.97). When assessing intra-rater reliability, the kappa indices of two nurses were 0.54 (95% CI, 0.31 to 0.77) and 0.67 (95% CI, 0.47 to 0.87), whereas those of two physicians were 0.87 (95% CI, 0.62 to 1.00) and 0.37 (95% CI, -0.16 to 0.89). Conclusions: In this study, the medical record review for detecting adverse events showed intermediate to good level of inter-rater and intra-rater reliability. Well organized training program for reviewers and clearly defining SC are required to get more reliable results in the hospital adverse event study.

Dynamic Characteristic Analysis of Active Gurney Flap Considering Rotational Effect (회전 효과를 고려한 Active Gurney Flap 의 동특성 해석)

  • Kee, YoungJung;Kim, TaeJoo;Kim, DeogKwan
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • In this study, the finite element analysis was carried out to investigate dynamic characteristics of the AGF(Active Gurney Flap) which is under development for reducing vibration and noise of the helicopter rotor system. The Gurney flap is a kind of small flat plate, mounted normal to the lower surface of the airfoil near to the trailing edge. An electric motor, L-shaped linkages and flap parts were integrated into a rotor bade, and 3~5/rev control was given to the AGF to reduce the vibration in the fixed frame. Thus, an explicit time integration method was adopted to investigate the dynamic response of the AGF with considering both centrifugal force due to the rotor rotation and active control input, and it can be seen that the vertical displacement of the AGF was satisfied to meet the design requirement.

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

2D and quasi 3D computational models for thermoelastic bending of FG beams on variable elastic foundation: Effect of the micromechanical models

  • Merzoug, Mostafa;Bourada, Mohamed;Sekkal, Mohamed;Abir, Ali Chaibdra;Chahrazed, Belmokhtar;Benyoucef, Samir;Benachour, Abdelkader
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.361-374
    • /
    • 2020
  • This paper is concerned with the thermoelastic bending of FG beams resting on two-layer elastic foundations. One of these layers is Winkler springs with a variable modulus while the other is considered as a shear layer with a constant modulus. The beams are considered simply supported and subjected to thermo-mechanical loading. Temperature-dependent material properties are considered for the FG beams, which are assumed to be graded continuously across the panel thickness. The used theories contain undetermined integral terms which lead to a reduction of unknowns functions. Several micromechanical models are used to estimate the effective two-phase FG material properties as a function of the particles' volume fraction considering thermal effects. Analytical solutions for the thermo-mechanical bending analysis are obtained based on Navier's method that satisfies the boundary conditions. Finally, the numerical results are provided to reveal the effect of explicit micromechanical models, geometric parameters, temperature distribution and elastic foundation parameters on the thermoelastic response of FG beams.

Anaphoricity Determination of Zero Pronouns for Intra-sentential Zero Anaphora Resolution (문장 내 영 조응어 해석을 위한 영대명사의 조응성 결정)

  • Kim, Kye-Sung;Park, Seong-Bae;Park, Se-Young;Lee, Sang-Jo
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.12
    • /
    • pp.928-935
    • /
    • 2010
  • Identifying the referents of omitted elements in a text is an important task to many natural language processing applications such as machine translation, information extraction and so on. These omitted elements are often called zero anaphors or zero pronouns, and are regarded as one of the most common forms of reference. However, since all zero elements do not refer to explicit objects which occur in the same text, recent work on zero anaphora resolution have attempted to identify the anaphoricity of zero pronouns. This paper focuses on intra-sentential anaphoricity determination of subject zero pronouns that frequently occur in Korean. Unlike previous studies on pair-wise comparisons, this study attempts to determine the intra-sentential anaphoricity of zero pronouns by learning directly the structure of clauses in which either non-anaphoric or inter-sentential subject zero pronouns occur. The proposed method outperforms baseline methods, and anaphoricity determination of zero pronouns will play an important role in resolving zero anaphora.