• Title/Summary/Keyword: Expansion Method

Search Result 3,557, Processing Time 0.038 seconds

ASR Effectiveness of High Volume Fly Ash Cementitious Systems Using Modified ASTM C 1260 Test Method

  • Shon, Chang-Seon;Kang, Soo-Geon;Kim, Young-Su
    • KCI Concrete Journal
    • /
    • v.14 no.2
    • /
    • pp.76-80
    • /
    • 2002
  • The role of high volume Class F fly ash in reducing expansion due to Alkali-Silica Reaction (ASR) was investigated. A series of modified ASTM C 1260 tests were performed under three different levels of NaOH normality, extending the test period to 28 days, using high- or low alkali cement, and Class F fly ash up to 58 % by mass of cement. A reactive siliceous fine aggregate was used. The test results confirm that HVFA replacement in a cementitious system significantly helps in controlling expansion caused by ASR.

  • PDF

Design of the Wire Rope Type Snubber for Earthquake and Vibration of Piping System (Wire Rope형 배관 지진$\cdot$진동완충기의 설계)

  • 김영중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.173-179
    • /
    • 1998
  • The piping system of a power plant suffers not only thermal expansion according to the temperature variation, but also many kinds of load: steady state vibrations due to the equipment operation or fluid flow, and transient vibrations due to the earthquake or explosion, etc. The snubbers are usually installed on the piping system to allow thermal expansion, and to reduce dynamic responses. Most snubbers are kinds of hydraulic and mechanical type, which can be degraded by leakage and abrasion, and required much cost for maintenance and replacement. Recently the wire rope type snubbers are developed and applied to the power plant, and proved as effective to reduce piping system vibration. Wire rope type snubber uses the bending rigidity and energy dissipation properties of ropes. This paper presents the procedure of design, and the method to apply hysteresis curve to the dynamic response analysis. Experiments were also conducted to confirm design results.

  • PDF

Effect of viscous interfaces on bending of orthotropic rectangular laminate (직교 이방성 적층판의 굽힘에 대한 점성 경계면의 영향)

  • Kim, Geun-Woo;Lee, Kang-Yong;Chen, W.Q.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.180-185
    • /
    • 2004
  • This paper investigates asimply supported orthotropic rectangular laminate with viscous interfaces subjected to bending. Additional mathematical difficulty is involved due to the presence of viscous interfaces because the behavior of the laminate depends on time. A step-by-step state-space approach is suggested, which is directly based on the threedimensional theory of elasticity. In particular, Taylor's expansion theorem is employed to model the variations of field variables with time. The proposed method is suitable for analyzing laminated plate of arbitrary thickness. Numerical calculations are performed and it is shown that the viscous interfaces have a significant fluence on the response.

  • PDF

Development of manipulator for handling micro components in vacuum (진공용 초소형 제품조작을 위한 매니퓰레이터 제작)

  • Yun Deokwon;Choi Hyeunseok;Han Changsoo;Choi Hunjong;Hong Wonpyo;Kang Eungoo
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.40-44
    • /
    • 2005
  • Recently PZT is used in ultra precision mechanism field. PZT itself has a small driving range although it has a high resolution. Many methods, such as inchworm, impact driving, inertial sliding method, etc., have been applied for moving range expansion. In this study, a new actuating mechanism for rotational motion with two driving PZT is proposed. The Fixed-Fixed beam support is applied for compensation of the difference in driving force between expansion and contraction of PZT. The behavior and design parameters of the proposed mechanism are analyzed for improving performance.

  • PDF

Preparation of composite particles by Rapid Expansion of Supercritical fluid Solutions and Release behavior

  • Ryu, Han-Won;Kim, Jung-Hwan;Kim, Young-Do;Shin, Kun-Chul
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.09a
    • /
    • pp.117-121
    • /
    • 1998
  • The Rapid Expansion of supercritical fluid Solutions (RESS) process was applied to particles coating. Experiments were conducted in a fluidized bed with an internal nozzle in the center of the reaction tube. Microcapsules (mean particle size : 49$\mu\textrm{m}$) prepared by spray drying method were used as the core particles. Supercritical CO2 solutions of paraffin were expanded through the nozzle in to the bed that was fluidized by air. Surface morphology prepared particles was observed by SEM. For the inspection of particle size change, particle size distributions were measured before and after coating. The releasing behavior of Mg2+ ions inspected by AA.

  • PDF

Numerical Simulation on Dynamic Characteristics of a Water Heater System Driven by a Heat Pump (열펌프 가열식 온수기의 동적특성 해석)

  • 김민성;김민수;백남춘
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2002
  • A dynamic model of a water heater system heated by a heat pump was developed. The water heater system was composed of heat pump and hot water reservoirs. Finite volume method (FVM) was applied to describe the heat exchangers. A new constraint on electronic expansion valve (EEV) or thermostatic expansion valve (TXV) that can control superheat after the evaporator was developed. Dynamic performances were evaluated for various sizes of the reservoir. In order to compare those performances, time scale was normalized by time constant representing the characteristics of reservoir size. Time constant was determined from quasi steady-state simulation of the system. From the simulation, the size of the water heater reservoir was found to have a large influence on the transient performance of the sys- tem. Therefore, the optimization of the reservoir size is needed in a design process.

Frost Heaving Pressure Characteristics of Frozen soils with Frost-Susceptibility and Degree of Saturation (흙의 동상민감성과 포화도를 고려한 동상팽창압 특성)

  • 신은철;박정준;김종인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.329-336
    • /
    • 2002
  • The earth structures and in-ground LNG tank, and buildings can be constructed with using artificial freezing method on the reclaimed land. In this study, upon freezing a saturated soil in a closed-system from the top, a considerable pressure was developed. The pressure is the result of the surface energy of a curved ice-water interface. The most significant of these parameters will have the greatest effect on the classification. In order to establish frost-susceptibility criteria based on frost heaving expansion pressure, more soils have to be tested. This study was initiated to investigate the soils frost heaving expansion pressure and moisture characteristics resulting from freezing and freezing-thawing cycle process. Weathered granite soils, sandy soil, sandy soil were used in the laboratory freezing test subjected to thermal gradients under closed- systems.

  • PDF

Analysis of Underpinning Construction Cases for Underground Space Expansion (지하공간 확장을 위한 언더피닝 사례분석)

  • Choi, In-Sub;Rhim, Hong-Chul;Kim, Yang-Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.11-12
    • /
    • 2013
  • It is required to response to the demand for new space due to high density of population and buildings in urban area. In particular, in case of big cities such as Seoul where the lack of new construction site due to the depletion of available space, existing buildings must be demolished for new construction. Utilization of urban underground space can be an alternative to solve for urban space problems. There are applications of underpinning methods using micropiles for existing buildings. Sometimes, the difficulties come from the compact space available for new foundation underneath the existing ones. In this paper, a novel underpinning method is introduced which can solve the space restriction problems underneath existing columns.

  • PDF

Characteristics of Anode Electrode According to Ni Content for Solid Oxide Fuel Cell (고체전해질형 연료전지의 Ni 함량에 따른 연료극 특성)

  • 김귀열;엄승욱;문성인
    • Electrical & Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.528-532
    • /
    • 1997
  • The research and development for the solid oxide fuel cell have been promoted rapidly and extensively in recent years, because of their high efficiency and future potential. Therefore this paper describes the manufacturing method and characteristics of anode electrode for SOFC, by the way, Ni-YSZ materials are used as anode of SOFC widely. So in this experiments, we investigated the optimum content of Ni, by testing expansion coefficient, impedance characteristics, overvoltage. As a result, the performance of Ni-YSZ anode(40vol%) was better excellent than the others.

  • PDF

Probabilistic Load Flow for Power Systems with Wind Power Considering the Multi-time Scale Dispatching Strategy

  • Qin, Chao;Yu, Yixin;Zeng, Yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1494-1503
    • /
    • 2018
  • This paper proposes a novel probabilistic load flow model for power systems integrated with large-scale wind power, which considers the multi-time scale dispatching features. The ramp limitations of the units and the steady-state security constraints of the network have been comprehensively considered for the entire duration of the study period; thus, the coupling of the system operation states at different time sections has been taken into account. For each time section, the automatic generation control (AGC) strategy is considered, and all variations associated with the wind power and loads are compensated by all AGC units. Cumulants and the Gram-Charlier expansion are used to solve the proposed model. The effectiveness of the proposed method is validated using the modified IEEE RTS 24-bus system and the modified IEEE 118-bus system.