• Title/Summary/Keyword: Evacuation Route

Search Result 139, Processing Time 0.022 seconds

Damages, Human Behaviour and Recovery of Urban Residents in the 2005 West off Fukuoka Earthquake

  • Murakami, H.
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.13-18
    • /
    • 2008
  • The 2005 west off Fukuoka earthquake with Mjma 7.0 occurred in the vicinity of Fukuoka city with 1.4 million populations, which had been regarded as rather seismically inactive in Japan. The strong motion records by K-net indicated PGV of 64 cm/s in Fukuoka city and some condominium buildings sustained extensive non-structural damages. In this study, we conducted a questionnaire survey for residents of 8 condominium buildings located in the downtown area of Fukuoka city after the earthquake. The results indicate that damaged nonstructural walls and distorted doors disrupted evacuation route for many occupants, and furniture and content damage on upper floors became severer resulting in higher rates of human casualty. Earthquake preparedness for indoor safety was raised after the earthquake, though further safety measures can be advised. In the phase of post-earthquake emergency and restoration period, residents' management organizations play important roles, so that neighborhood activities to promote communication networks are important in urban environment with aging population.

  • PDF

Evacuation Route Searching when disasters occur in indoor utilizing audible·inaudible signal (가청·비 가청 대역을 활용한 실내 공간에서 재난발생 시 대피 경로 탐색방안)

  • Kim, Nam-moon;Kim, Jung-gon;Kim, Young-ok
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.72-74
    • /
    • 2015
  • 본 논문에서는 시뮬레이션에 머물렀던 기존의 재난 대피경로 안내 기술을 지향성 스피커와 스마트 디바이스와 결합하여 실제 재난발생 시 적용 가능한 기술을 제안하고자 한다. 기존의 연구에서 얻은 대피 경로에 대한 정보를 기반으로 지향성 스피커의 방향과 소리의 크기 등의 컨트롤을 통해서 대피자들이 대피 방향을 인지할 수 있도록 하고, 보유하고 있는 스마트 디바이스를 활용하여 대피 방향에 대한 탐색을 통해서 재난으로부터 발생되는 인명 피해를 최소화 하는 기술을 제안하였다. 또한, 가청 과 비 가청 대역을 이용한 대피 안내 방송 송출을 통해서, 재난 발생으로 혼란한 상황에서도 대피 방향 탐색의 정확도를 높일 수 있는 기술을 제안 하였다.

  • PDF

A Study on the Development of Performance Based Fire Risk Assesment Program (FDS를 활용한 성능위주 화재위험성평가 프로그램개발에 관한 연구)

  • Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • `SOS', Simulator Of Safety assessment for fire, was developed to simulate fire safety assessment for a structure which is geometrically complex. The program(SOS) is intended to use for searching as well as designing tools to analyse the evacuation safety through a wide range of structure conditions. The computer program has a function which importing FDS's calculating results to each individual resident in the structure. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments individual speeds in accordance with the proximity of crowd members. This SOS program contributes to a computer package that evaluates the fire safety assessment of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

An Experimental Study on the Pressure Differentials during the Pressurized Air Supply to the Elevator Lobby (부속실 급기가압제연시 차압변화에 관한 실험적 연구)

  • Kim, Bum-Kyu;Park, Yong-Hwan;Kim, Hong-Sik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.110-119
    • /
    • 2009
  • A fire should be accompanied by the heat and smoke. However, smoke is considered main cause of heavy casualties. Smoke easily spreads away from the fire area to remote space and cause mortal wound for the resident. A technical way effectively protecting the life and property from the smoke is the smoke control system of the building. Pressurized air supply system can be considered to prevent the refuge area from the smoke infiltration that evacuate residents via evacuation route for life safety. This paper is related with performance estimation and the effectiveness of the pressurized air supply system through experiments.

  • PDF

Countermeasure against Fire Disaster in Regional Heritage Villages on the Concept of ICT-Based Disaster Prevention Design

  • Park, Sun-Gyu;Mishima, Nobuo;Noh, Hwang-Woo;Yoo, Jae-Soo;Oh, Sang-Hoon;Min, Byung-Won;Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.11 no.1
    • /
    • pp.62-68
    • /
    • 2015
  • Many severe earthquakes have occurred along the main fault lines in the world. In recent years, there has been a high incidence of small- and large-scale earthquakes in our country. These occurrences of earthquakes have become increasingly serious, owing to a degrading earth environment. An earthquake, in general, causes far more serious damages like disruptions in electricity or gas facilities, and fire disasters from its annexed effects than by its vibrations or the shock itself. In this paper, we present a countermeasure and its necessity in safeguarding against fire disasters in regional heritage villages such as "Asan Oeam," "Jeonju Hanok," and "Andong Hahoe." A more systematic and effective strategy for prevention systems against severe fire disasters is proposed after performing various related investigations and analyses of existing domestic and international systems. We investigated the existing fire security systems and their historical records with the tendency of earthquake occurrences in these three folk villages. In this proposal, we present a strategic approach for safeguarding against fire damages in our regional heritage villages derived from ICT (information communication technology)-based DPD (disaster prevention design), after examining the laws and regulations of fire-prevention strategies in Japan, America, and Europe.

Change of safety consciousness of passengers onboard ship after the Sewol ferry incident (세월호 사고 발생에 따른 여객선 승객의 안전의식 변화)

  • Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1156-1162
    • /
    • 2014
  • To prevent the Sewol incident again, by which the victims are 294 dead and still 10 missing, this study analyzed the change of safety consciousness of passengers onboard ship comparatively before and after the Sewol incident. The survey had performed 2 times at Jeju coastal cruise terminal at February 2014 and May 2014, and effective respondents were 394 and 401, respectively. After the Sewol incidents, the answers' ratio that they would follow the routes that the crews show and they would follow the crews' evacuation guides are decreased 24.5% and 18.5%, respectively. This means that the reliability on the crew members were decreased. Although 77.6% passengers responded that they felt nervousness onboard ship, 60% did not take safety lesson(s) and 45% did not know how to wear a life jacket. And also over 50% did not check the evacuation route map and the location of lifeboat, respectively. Meanwhile, 86.9% respondents answered the system of safey lesson should be changed, which has normally done by TV set.

Derivations of Positive Pressure Condition for Development of Foldable Safe Pathway in Railway Tunnel Fires (철도터널화재용 접이식 대피통로 개발을 위한 양압 조건 도출)

  • Kim, JiTae;Ro, Kyoungchul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.284-289
    • /
    • 2019
  • The Korea Foldable safe pathway system is an evacuation support system to get temporary evacuation route in railway tunnel and large space fires. A prevention smoke screen is unfolded in fires and it is needed to prevent heat and smoke from fire source. Therefore, ventilation system for positive pressure condition is equipped with foldable safe pathway system. Numerical analyses of temperature and pressure distribution with distance from fire source were performed considering fire scenario of new train vehicle. The smoke temperatures did not exceed $200^{\circ}C$ that distance from the fire source was more than 20 m and smoke pressure was reduced with distance from fire source. Maximum smoke pressure was 14 Pa and average pressure was 6 Pa in position of prevention smoke screen. As results, to install foldable safe pathway system, ventilation system is need to maintain 6 Pa positive pressure condition.

A Study on an Adaptive Guidance Plan by Quickest Path Algorithm for Building Evacuations due to Fire (건물 화재시 Quickest Path를 이용한 Adaptive 피난경로 유도방안)

  • Sin, Seong-Il;Seo, Yong-Hui;Lee, Chang-Ju
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.197-208
    • /
    • 2007
  • Enormously sized buildings are appearing world-wide with the advancement of construction techniques. Large-scaled and complicated structures will have increased difficulties for dealing with safety, and will demand well-matched safety measures. This research introduced up-to-date techniques and systems which are applied in buildings in foreign nations. Furthermore, it proposed s direct guidance plan for buildings in case of fire. Since it is possible to install wireless sensor networks which detect fires or effects of fire, the plan makes use of this information. Accordingly, the authors completed a direct guidance plan that was based on omnidirectional guidance lights. It is possible to select a route with concern about both time and capacity with a concept of a non-dominated path. Finally, case studies showed that quickest path algorithms were effective for guiding efficient dispersion routes and in case of restriction of certain links in preferred paths due to temperature and smoke, it was possible to avoid relevant links and to restrict demand in the network application. Consequently, the algorithms were able to maximize safety and minimize evacuation time, which were the purposes of this study.

Human Security Dimension Israel-Hamas War and Security Policy Implications (인간안보 차원 이스라엘-하마스 전쟁과 안보정책적 함의)

  • Il Soo Bae;Hee Tae Jeong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.17-22
    • /
    • 2024
  • The war that broke out on October 7, 2023 is prolonging and expanding into the Middle East. Although the damage from war is increasing, humanitarian aid to the Gaza Strip has been halted due to UNRWA's deviant actions. Powerful countries have suspended support, and the UN is appealing for support for the Gaza Strip. All damage is borne by civilians in the Gaza Strip, especially women, children, and the elderly. Israel has selected an evacuation zone and evacuation route in the Gaza Strip and established a humanitarian aid route in the border area. However, Hamas's resistance in underground tunnels, using civilian-dense areas and civilian facilities such as hospitals and schools as shields, further amplified civilian casualties. This Israel-Hamas war requires the international community to approach it from a human security perspective. We must strengthen the UN's functions and roles to ensure that humanitarian supplies reach the field and humanitarian intervention forces ensure human dignity and basic rights. We must restore the credibility of the UN's role through the Israel-Hamas war. In addition, Korea should urge the introduction of humanitarian aid and goods, and provide humanitarian goods such as daily necessities and medicine. We must also prepare for deployment as a member of the UN peacekeeping force in the future. These activities will help Korea develop into a model country that fulfills its role as a 'global pivotal nation' and will have a virtuous cycle of international support in the event of a future crisis on the Korean Peninsula.

Evaluation of the Appropriateness of Smoke Control Conditions of Platform at the Subway Fire by using FDS (FDS를 이용한 지하철 객실 화재 시 승강장 제연조건의 적정성 평가)

  • Kim, Ki-Sung;Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.8-14
    • /
    • 2013
  • In the subway, various fires continue to take place across the world. In the Daegu subway accident in 2003, many people were damaged by shortened visibility range caused by toxic gas and smoke. This paper, assuming that a subway fire happens in the Mandeok Station of the subway system in Busan, analyzed different smoke-spreading situations depending on the ventilation situation at its platform (opening of the train doors, operation of ventilation facilities in the tunnel, and working of fire door), using FDS. The calculation proved that it would be more effective to secure evacuation route when the ventilation facilities of the tunnel are not operated, than when they are on. And, it was also found that the case where the doors of the platform to the escape route and only the platform-facing doors of the subway car on fire office are open would be more effective to ventilation than the case where all the doors are open. And, it was found to be important that the fire doors of the platform are working properly.