• Title/Summary/Keyword: Evacuation Flow

Search Result 124, Processing Time 0.04 seconds

Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization (샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구)

  • Kim, Jung-Yup;Ahn, Chan-Sol
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Amid the growing number of high-rise complex buildings in Korea, efficient smoke prevention technology in a fire is required and as an alternative of a mechanical smoke control system in high-rise buildings, the use of a smoke control system using sandwich pressurization has been on the rise. In such a system, the appropriate pressure difference and the data for designing the air supply and exhaust flow rate are necessary to prevent the spread of smoke and offer a tenable evacuation environment. As part of such effort, this paper presents a field test process and result after testing a building where such a smoke control system using sandwich pressurization has been installed. A ventilation rate of 6 cycles per hour were applied to simulate the air exhaust flow rate on a fire floor and the air supply flow rate on the floors above and below the fire floor. As a result of the system operation, pressure difference of approximately 260 Pa between the 12th floor of a fire and the 13th floor was generated. The over pressure of the experiment has a serious effect on the evacuation or fire compartment so that it is necessary to examine the improvement.

Characteristics of Sediment Movement and Local Peoples' Countermeasure for Evacuation in July 2006, Kangwon Province (2006년 7월 강원도 토석류발생 특징 및 주민 대응)

  • Kim, Gyeong-Nam;Gang, Sang-Hyeok;Han, Dong-Jun;Kim, Jeong-Han
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.267-270
    • /
    • 2007
  • In order to reduce flood damage with debris flow, it is necessary to build up comprehensive flood control, including structural and non-structural countermeasures. In this paper, the decision making factors of individual refuge activities which are major non-structural activities to save peoples, lives against flood have been estimated based on questionnaire survey. Furthermore, in order to effective debris flow countermeasures, its simulation has carried out and it will useful for minimizing their damages.

  • PDF

Development of Pressure Differential Smoke Control System for Separating the Leakage Air Flow and the Supplementary Air Flow (분리급기형 급기가압 제연시스템 개발)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.310-313
    • /
    • 2011
  • 국내에서 고층건물의 제연시스템으로 급기가압 제연시스템이 일반적으로 사용되고 있는데, 기존의 급기가압 제연시스템의 설계방안과 같이 한개의 급기풍도를 통해 누설량과 보충량이 동시에 공급될 경우에는 부속실과 옥내간에 형성되는 차압이 설계기준에 미달하거나 과압이 될 가능성이 매우 높아져서 급기가압 제연시스템의 설치목적을 달성하지 못할 수 있다. 이에 대한 개선방안으로 본 연구에서는 누설량의 공급과 보충량의 공급을 각기 다른 유로를 통해 수행하는 방안 및 장치구성을 제시함으로서 고층건물에서 화재 발생시 안전한 피난환경을 제공하고자 한다.

  • PDF

Characteristics of Sediment Movement and Local Peoples' Countermeasure for Evacuation - focused on Inie areas of Kangwon-do - (집중 호우에 따른 부유토사 유출 특징 및 주민 대응 -2006넌 7월 강도 인제 지역을 중심으로-)

  • Kang, Sang-Hyeok
    • Spatial Information Research
    • /
    • v.16 no.1
    • /
    • pp.11-17
    • /
    • 2008
  • In order to reduce flood damage with debris flow, it is necessary to build up comprehensive flood control, including structural and non-structural countermeasures. In this paper, the decision making factors of individual refuge activities which are major non-structural activities to save peoples, lives against flood have been estimated based on questionnaire survey. Furthermore, in order to effective debris flow countermeasures, its simulation has carried out and it will useful fur minimizing their damages.

  • PDF

Development and Verifying of Calculation Method of Standard Rainfall on Warning and Evacuation for Forest Soil Sediment Disaster in Mountainous Area by Using Tank Model (Tank Model을 이용한 산지토사재해 경계피난 기준우량 산정법 개발 및 검토)

  • Lee, Chang-Woo;Youn, Ho Joong;Woo, Choong Shik
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.272-278
    • /
    • 2009
  • This study was conducted to develope calculation method of standard rainfall, which was used for predicting the outbreaking time of disaster by using Tank model, on warning and evacuation for soil sediment disaster. We investigate adeption possibility of developed method through comparing storage function method with Tank model. We calculated storage amount rainfall by storage function method and Tank model with 36 hillslope failures which have record on outbreaking time of disaster. The result in case of Sedimentary (quarternary period) showed that the difference of outbreaking time was 1.6 hour in case of tank model, but 3.2 hour in case of storage function method. In addition, the deviation of the peak storage were 7% in case of tank model, but 63% in case of storage function method. Total evacuation period was analyzed by using observed 5 years (1993-1997) rainfall data as well as each standard rainfalls which were determinated by two methods. The result showed that evacuation time by storage function method was about twice as many as that by tank model. Therefore, we concluded that calculation by tank model for predicting the outbreaking time of disaster was more useful and accurate than storage function method.

Numerical Study of the Factors Affecting Fire Flow Velocity in the Case of Interior Fire in an Apartment Building (공동주택 화재 시 화재풍속에 영향을 미치는 인자들에 관한 수치해석적 연구)

  • Kim, Byeongjun;Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2016
  • When an interior fire occurs in an apartment building, pollution of the entrance area by fire smoke before an air fan operates makes the evacuation of people very difficult aswhen the fire doors are opened. Numerical simulations using Fire Dynamics Simulator were conducted to determine the impact of a sprinkler on the fire flow velocity. The fire flow velocity was compared depending on the presence of sprinklers and the sprayed droplet size. The configuration and actual dimensions of an apartment building were used in the numerical simulations. The simulation results showed that fire flow velocity becomes smaller when a sprinkler is installed. In addition, the smaller droplet size results in a smaller fire flow velocity because smaller droplets can be evaporated more easily.

Evacuation Time for Performance Based Design (성능 위주 설계를 위한 피난 시간 계산)

  • Jung, Soo-Young;Kim, Tae-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.179-184
    • /
    • 2010
  • 성능 위주 피난 설계에 있어서 요구피난시간(RSET)을 위한 Simulex 등 피난 시뮬레이션 툴이 사용하고 있는 근본적인 데이터베이스, 즉, 시설 및 군중 조건에 따른 이동 변수, 최대 비유동률(Maximum Specific Flows) 및 경계폭(Boundary Layer Width)을 살펴보고, 트래픽 방정식(Traffic Equation)을 통한 계산 사례 즉, 피난자의 이동 속도 계산 사례, 최소 피난 시간 계산 사례 및 총 유동 용량(Flow Capacity) 수식과 계산 사례를 살펴본다.

  • PDF

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Flow Rate of Supply and Leakage (보충량과 누설량을 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. As one of the fire safety standards designed to secure the smoke safety, NFSC501A (Design Guide for Smoke Control System of Special Evacuation Stairwell and Lobby) has been proposed, preventing smoke from penetrating into the smoke-free escape route by raising the pressure of the smoke control zone higher than fire area. For model building of 20 stories, pressurization system was designed according to standard and pressure field of compartments in whole building induced by pressurization system was analyzed using the network model.

Measurement and Analysis of Moving Velocity of Elementary School Students Under a Escape Drill (초등학생의 피난 훈련 상황하에서의 이동속도 측정 및 분석에 관한 연구)

  • 김응식;이정수;김수영
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.1-6
    • /
    • 2003
  • This study measures the various moving velocities of elementary school children under situation of fire drill and suggests the methods of analysis. The velocities are such as the exiting velocity at the door of the classroom, personal walking velocity at corridor, velocity according to density of crowd and personal walking velocity at stairway. For these measurement an elementary school in Daejeon is chosen and 15 girls and 15 boys are selected in each grade. Finally speed data of the children is obtained and we can apply this data for the evacuation simulation of a school.

A Study on Circulation planning of the disabled in Local Cultural arts center (지역문화시설의 지체장애인 동선계획에 관한 연구 - 광주지역 문화시설을 중심으로 -)

  • Lee, Su-Yong;Park, Dong-Jun;Oh, Se-Gyu
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.11 no.2
    • /
    • pp.73-81
    • /
    • 2005
  • The disabled has remarkable difficulties to participate social activities and those, that block them up from access to public facilities and the comfortable habitation so they should get help from others, are mainly made by architectural facts. Buildings without impediment which consider the disabled would be the things responding to the needs of the times. If the disabled would be convenient to use facilities, there should be no difficulties to normal people. A first began to examine into the role of the architecture. And to establish radical standards for the disabled to use cultural and assembly facilities through scrutinizing facilities to get access for the disabled and movement circulations in the cultural facilities should be the conclusion. This study which is a kind of fundamental study to construct cultural facilities without obstacles for the disabled began from consideration for the problem flow line of the disabled in cultural facilities and analyzed flow lines for them to use, access, and evacuate from those which are main facilities in the region. Though, evacuation rules in cultural and assembly facilities are recommendatory in existing laws for convenience of the disabled, the congestion of the crowd coming out after performances impedes safe flows of both the disabled and crowds. Further, in case of evacuation, there would be more serious problems. Therefore, consideration of reinforcement for existing laws for convenience of the disabled is needed.

  • PDF