• Title/Summary/Keyword: Error Rate of Matching

Search Result 121, Processing Time 0.029 seconds

Block-based Motion Vector Smoothing for Nonrigid Moving Objects (비정형성 등속운동 객체의 움직임 추정을 위한 블록기반 움직임 평활화)

  • Sohn, Young-Wook;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.6
    • /
    • pp.47-53
    • /
    • 2007
  • True motion estimation is necessary for deinterlacing, frame-rate conversion, and film judder compensation. There have been several block-based approaches to find true motion vectors by tracing minimum sum-of-absolute-difference (SAD) values by considering spatial and temporal consistency. However, the algorithms cannot find robust motion vectors when the texture of objects is changed. To find the robust motion vectors in the region, a recursive vector selection scheme and an adaptive weighting parameter are proposed. Previous frame vectors are recursively averaged to be utilized for motion error region. The weighting parameter controls fidelity to input vectors and the recursively averaged ones, where the input vectors come from the conventional estimators. If the input vectors are not reliable, then the mean vectors of the previous frame are used for temporal consistency. Experimental results show more robust motion vectors than those of the conventional methods in time-varying texture objects.

Iris Recognition Using the 2-D Gabor Filter (2-D Gabor 필터를 이용한 홍채인식)

  • Go, Hyoun-Joo;Lee, Dae-Jong;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.6
    • /
    • pp.716-721
    • /
    • 2003
  • This paper deals with the iris recognition as one of biometric techniques which are applied to identify a person using his/her behavior or congenital characteristics. The iris of a human eye has a texture that is unique and time invariant for each individual. First, we obtain the feature vector from the 2D iris pattern having a property of size invariant and divide it into 24 sectors which are further through three types of 2D Gabor filters. At the recognition process, we compute the similarity measure based on the correlation values. Here, since we use three different matching values obtained from three different directional Gabor filters and select the maximum value among them, it is possible to minimize the recognition error rate. To show the usefulness of the proposed algorithm, we applied it to a biometric database consisting of 50 iris patterns extracted from 10 subjects and finally get more higher than 90% recognition rate.

Iris Recognition using Gabor Wavelet and Fuzzy LDA Method (가버 웨이블릿과 퍼지 선형 판별분석 기법을 이용한 홍채 인식)

  • Go Hyoun-Joo;Kwon Mann-Jun;Chun Myung-Geun
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.11
    • /
    • pp.1147-1155
    • /
    • 2005
  • This paper deals with Iris recognition as one of biometric techniques which is applied to identify a person using his/her behavior or congenital characteristics. The Iris of a human eye has a texture that is unique and time invariant for each individual. First, we obtain the feature vector from the 2D Iris pattern having a property of size invariant and using the fuzzy LDA which is further through four types of 2D Gabor wavelet. At the recognition process, we compute the similarity measure based on the correlation values. Here, since we use four different matching values obtained from four different directional Gabor wavelet and select the maximum value, it is possible to minimize the recognition error rate. To show the usefulness of the proposed algorithm, we applied it to a biometric database consisting of 300 Iris Patterns extracted from 50 subjects and finally got more higher than $90\%$ recognition rate.

Fixed-Point Modeling and Performance Analysis of a SIFT Keypoints Localization Algorithm for SoC Hardware Design (SoC 하드웨어 설계를 위한 SIFT 특징점 위치 결정 알고리즘의 고정 소수점 모델링 및 성능 분석)

  • Park, Chan-Ill;Lee, Su-Hyun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.49-59
    • /
    • 2008
  • SIFT(Scale Invariant Feature Transform) is an algorithm to extract vectors at pixels around keypoints, in which the pixel colors are very different from neighbors, such as vortices and edges of an object. The SIFT algorithm is being actively researched for various image processing applications including 3-D image constructions, and its most computation-intensive stage is a keypoint localization. In this paper, we develope a fixed-point model of the keypoint localization and propose its efficient hardware architecture for embedded applications. The bit-length of key variables are determined based on two performance measures: localization accuracy and error rate. Comparing with the original algorithm (implemented in Matlab), the accuracy and error rate of the proposed fixed point model are 93.57% and 2.72% respectively. In addition, we found that most of missing keypoints appeared at the edges of an object which are not very important in the case of keypoints matching. We estimate that the hardware implementation will give processing speed of $10{\sim}15\;frame/sec$, while its fixed point implementation on Pentium Core2Duo (2.13 GHz) and ARM9 (400 MHz) takes 10 seconds and one hour each to process a frame.

A Study on Touchless Finger Vein Recognition Robust to the Alignment and Rotation of Finger (손가락 정렬과 회전에 강인한 비 접촉식 손가락 정맥 인식 연구)

  • Park, Kang-Ryoung;Jang, Young-Kyoon;Kang, Byung-Jun
    • The KIPS Transactions:PartB
    • /
    • v.15B no.4
    • /
    • pp.275-284
    • /
    • 2008
  • With increases in recent security requirements, biometric technology such as fingerprints, faces and iris recognitions have been widely used in many applications including door access control, personal authentication for computers, internet banking, automatic teller machines and border-crossing controls. Finger vein recognition uses the unique patterns of finger veins in order to identify individuals at a high level of accuracy. This paper proposes new device and methods for touchless finger vein recognition. This research presents the following five advantages compared to previous works. First, by using a minimal guiding structure for the finger tip, side and the back of finger, we were able to obtain touchless finger vein images without causing much inconvenience to user. Second, by using a hot mirror, which was slanted at the angle of 45 degrees in front of the camera, we were able to reduce the depth of the capturing device. Consequently, it would be possible to use the device in many applications having size limitations such as mobile phones. Third, we used the holistic texture information of the finger veins based on a LBP (Local Binary Pattern) without needing to extract accurate finger vein regions. By using this method, we were able to reduce the effect of non-uniform illumination including shaded and highly saturated areas. Fourth, we enhanced recognition performance by excluding non-finger vein regions. Fifth, when matching the extracted finger vein code with the enrolled one, by using the bit-shift in both the horizontal and vertical directions, we could reduce the authentic variations caused by the translation and rotation of finger. Experimental results showed that the EER (Equal Error Rate) was 0.07423% and the total processing time was 91.4ms.

A Construction of Geographical Distance-based Air Quality Dataset Using Hospital Location Information (병원위치정보를 이용한 지리적 거리기반의 대기환경 데이터셋 구축)

  • Kim, Hyeongsoo;Ryu, Keun Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.3
    • /
    • pp.231-242
    • /
    • 2016
  • As of late, air quality information has been actively gathered and investigated in order to find possible environmental risk factors that may affect the onset of cardiovascular disease. Nevertheless, existing studies are limited in the detailed analysis because they take advantage of the air quality information of the macro statistics divided into administrative districts. This paper proposes the construction of distance-based air quality dataset using a domestic hospital’s geographical location information as a reliable data gathering step for a more detailed analysis of environmental risk factors. For the construction of the dataset, air quality information was obtained by utilizing the geographical location of a hospital—in which a patient with cardiovascular disease had been admitted—and then matching the hospital with a meteorological and air pollution station in its vicinity. An air quality acquisition system based on GMap.net was devised for the purpose of data gathering and visualization. The reliability of the experiment was confirmed by evaluating the matching rate and error of air quality values between the acquired dataset with existing area-based air quality datasets from matched distances. Therefore, this dataset, which considers geographical information, can be utilized in multidisciplinary research for the discovery of environmental risk factors that can affect not only cardiovascular diseases but also potentially other epidemic diseases.

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.

A Study on Utilization 3D Shape Pointcloud without GCPs using UAV images (UAV 영상을 이용한 무기준점 3D 형상 점군데이터 활용 연구)

  • Kim, Min-Chul;Yoon, Hyuk-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.97-104
    • /
    • 2018
  • Recently, many studies have examined UAVs (unmanned aerial vehicles), which can replace and supplement existing surveying sensors, systems, and images. This study focused on the use of UAV images and assessed the possibility of utilization in areas where it is difficult to obtain GCPs (ground control points), such as disasters. Therefore, 3D (dimensional) pointcloud data were generated using UAV images and the absolute/relative accuracy of the generated model data using GCPs and without GCPs was assessed. The results showed the 3D shape pointcloud generated by UAV image matching was proven if the relative accuracy was set, regardless of whether GCPs were used or not; the quantitative measurement error rate was within 1%. Even if the absolute accuracy was low, the 3D shape pointcloud that had been post processed quickly was sufficient to be utilized when it is impossible to acquire GCPs or urgent analysis is required. In particular, the results can obtain quantitative measurements and meaningful data, such as the length and area, even in cases with the ground reference point surveying and post-process.

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Forward Error Correction based Adaptive data frame format for Optical camera communication

  • Nguyen, Quoc Huy;Kim, Hyung-O;Lee, Minwoo;Cho, Juphil;Lee, Seonhee
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.94-102
    • /
    • 2015
  • Optical camera communication (OCC) is an extension of Visible Light Communication. Different from traditional visible light communication, optical camera communications is an almost no additional cost technology by taking the advantage of build-in camera in devices. It was became a candidate for communication protocol for IoT. Camera module can be easy attached to IoT device, because it is small and flexible. Furthermore almost smartphone equip one or two camera for both back and font side with high quality and resolution. It can be utilized for receiving the data from LED or positioning. Actually, OCC combines illumination and communication. It can supply communication for special areas or environment where do not allow Radio frequency such as hospital, airplane etc. There are many concept and experiment be proposed. In this paper we proposed utilizing Android smart-phone camera for receiver and introduce new approach in modulation scheme for LED at transmitter. It also show how Manchester coding can be used encode bits while at the same time being successfully decoded by Android smart-phone camera. We introduce new data frame format for easy decoded and can be achieve high bit rate. This format can be easy to adapt to performance limit of Android operator or embedded system.