• Title/Summary/Keyword: Error Characteristic

Search Result 971, Processing Time 0.029 seconds

Fully Automatic Liver Segmentation Based on the Morphological Property of a CT Image (CT 영상의 모포러지컬 특성에 기반한 완전 자동 간 분할)

  • 서경식;박종안;박승진
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.70-76
    • /
    • 2004
  • The most important work for early detection of liver cancer and decision of its characteristic and location is good segmentation of a liver region from other abdominal organs. This paper proposes a fully automatic liver segmentation algorithm based on the abdominal morphology characteristic as an easy and efficient method. Multi-modal threshold as pre-processing is peformed and a spine is segmented for finding morphological coordinates of an abdomen. Then the liver region is extracted using C-class maximum a posteriori (MAP) decision and morphological filtering. In order to estimate results of the automatic segmented liver region, area error rate (AER) and correlation coefficients of rotational binary region projection matching (RBRPM) are utilized. Experimental results showed automatic liver segmentation obtained by the proposed algorithm provided strong similarity to manual liver segmentation.

  • PDF

The Response Improvement of PD Type FLC System by Self Tuning (자기동조에 의한 PD 형 퍼지제어시스템의 응답 개선)

  • Choi, Hansoo;Lee, Kyoung-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.12
    • /
    • pp.1101-1105
    • /
    • 2012
  • This study proposes a method for improvement of PD type fuzzy controller. The method includes self tuner using gradient algorithm that is one of the optimization algorithms. The proposed controller improves simple Takagi-Sugeno type FLC (Fuzzy Logic Control) system. The simple Takagi-Sugeno type FLC system changes nonlinear characteristic to linear parameters of consequent membership function. The simple FLC system could control the system by calibrating parameter of consequent membership function that changes the system response. While the determination on parameter of the simple FLC system works well only partially, the proposed method is needed to determine parameters that work for overall response. The simple FLC system doesn't predict the response characteristics. While the simple FLC system works just like proportional part of PID, our system includes derivative part to predict the next response. The proposed controller is constructed with P part and D part FLC system that characteristic parameter on system response is changed by self tuner for effective response. Since the proposed controller doesn't include integral part, it can't eliminate steady state error. So we include a gain to eliminate the steady state error.

Development of Force Sensors of Toes and Heel for Humanoid Robot's Intelligent Foot (인간형 로봇의 지능형 발의 발가락 및 뒤꿈치 힘센서 개발)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.61-68
    • /
    • 2010
  • In order to let the humanoid robot walk on the uneven terrains, the robot's foot should have the similar structure and function as human's. The intelligent foot should be made up of toes and heel. When it walks on the uneven terrains, the foot's sole senses the force and adjusts foot's position before robot losing his balance. In this paper, the force sensors of robot's intelligent foot for having the similar structure and function like human are developed. The heel 3-axis force/moment sensor and toe force sensors for humanoid robot's intelligent foot is developed, and the characteristic tests of them are carried out. As a result of characteristic test, the interference error of the heel 3-axis force/moment sensor is less than 2.2%. It is thought that the developed force sensors could be used to measure the reaction forces which is applied the toes and the heel of a humanoid robot.

Calibration Techniques for Low-Level Current Measurement in the Characteristic Analysis System for Semiconductor Devices (저전류 측정을 위한 반도체 소자 특성 분석 시스템에서의 보상 기법)

  • Choi, In-Kyu;Park, Jong-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2002
  • In this paper, we proposed calibration techniques to improve measurement accuracy in the characteristic analysis system for semiconductor devices. Systematic errors can be reduced using proposed calibration techniques. Also, error current reduction procedures including leakage current and offset current are proposed to measure low-level current in pA level. Calibration parameters are calculated and stored by microprocessor using least-square fitting with measured sample data. During measurement time microprocessor corrects measured data using stored calibration parameters. Experimental results show that current measurement error above nA level is less than 0.02%. And they also show that current measurement in pA level can be performed with about 0.2% accuracy.

Accuracy and Error Characteristics of SMOS Sea Surface Salinity in the Seas around Korea

  • Park, Kyung-Ae;Park, Jae-Jin
    • Journal of the Korean earth science society
    • /
    • v.41 no.4
    • /
    • pp.356-366
    • /
    • 2020
  • The accuracy of satellite-observed sea surface salinity (SSS) was evaluated in comparison with in-situ salinity measurements from ARGO floats and buoys in the seas around the Korean Peninsula, the northwest Pacific, and the global ocean. Differences in satellite SSS and in-situ measurements (SSS errors) indicated characteristic dependences on geolocation, sea surface temperature (SST), and other oceanic and atmospheric conditions. Overall, the root-mean-square (rms) errors of non-averaged SMOS SSSs ranged from approximately 0.8-1.08 psu for each in-situ salinity dataset consisting of ARGO measurements and non-ARGO data from CTD and buoy measurements in both local seas and the ocean. All SMOS SSSs exhibited characteristic negative bias errors at a range of -0.50- -0.10 psu in the global ocean and the northwest Pacific, respectively. Both rms and bias errors increased to 1.07 psu and -0.17 psu, respectively, in the East Sea. An analysis of the SSS errors indicated dependence on the latitude, SST, and wind speed. The differences of SMOS-derived SSSs from in-situ salinity data tended to be amplified at high latitudes (40-60°N) and high sea water salinity. Wind speeds contributed to the underestimation of SMOS salinity with negative bias compared with in-situ salinity measurements. Continuous and extensive validation of satellite-observed salinity in the local seas around Korea should be further investigated for proper use.

Rubust controller for inverter using CRA (CRA를 이용한 인버터 강인제어기 설계)

  • Lee, Jin-Mok;Park, Ga-Woo;Lee, Jae-Moon;Jung, Hun-Sun;Noh, Se-Jin;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.98-100
    • /
    • 2007
  • This paper proposes a robust digital controller for PWM voltage source inverter using CRA method. The usual inverter controller for the operation of constant voltage and constant frequency consists of a double looped PI controller for the outer voltage controller and the inner current controller, of which the order of characteristic polynomial is high and so the gain tuning is difficult. Considering the limited switching frequency of the devices and sampling frequency of the digital controller, the gain tuning is usually based on the engineering experiences with the try and error method. In this paper, the error-space approach is used to get the system model including the controller with low order, and the characteristic ratio assignment (CRA) method is proposed for the design of robust controller which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. The PSiM simulation and experience results are shown to verify the validity of the proposed controller.

  • PDF

Performance Evaluation of a Novel Chaos Transceiver for the High Level Modulation (고레벨 변조를 위한 새로운 카오스 송수신기의 성능 평가)

  • Lee, Jun-Hyun;Ryu, Heung-Gyoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Security of chaos communication system that has characteristic of sensitive initial conditions is superior to digital communication systems, but BER(Bit Error Rate) performance is evaluatied badly. So, studies in order to improve the BER performance is important. existing studies, BER performance of proposed chaos transceiver is possible to improve than the CDSK(Correlation Delay Shift Keying) system because it has characteristic that has very few addition elements like noise signal except for the desired signal. Chaos communication system has many symbols because it spreads according to characteristic of chaos map. Therefore, study that can have the good data rate in chaos communication system is required. Information bits of existing chaos modulation system are modulated as -1 and 1 on the basis of BPSK system. However, instead of BPSK system, if chaos communication system is applied high level modulation systems such as QPSK system and 16QAM system, it is possible to have good data rate because more data are transmitted at a time. In the paper, when QPSK system and 16QAM system are applied to proposed chaos transceiver in existing study, we evaluate the SER(Symbol Error Rate) performance and compare the each performance. Also, when QPSK system and 16QAM system are applied to proposed chaos transceiver, we evaluate the anti-jamming performance of proposed system.

Electrostatic Coupling Intra-Body Communication Based on Frequency Shift Keying and Error Correction (FSK 통신 및 에러 정정을 통한 Intra-Body Communication)

  • Cho, Seongho;Park, Daejin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.159-166
    • /
    • 2020
  • The IBC (Intra-Body Communication) benefits from a wireless communication system for exchanging various kinds of digital information through wearable electronic devices and sensors. The IBC using the human body as the transmission channel allows wireless communication without the transmitting radio frequency waves to the air. This paper discusses the results of experiments on electrostatic coupling IBC based on FSK (Frequency Shift Keying) and 1 bit error correction. We implemented FSK communication and 1 bit error correction algorithm using the MCU boards and aluminum tape electrodes. The transmitter modulates digital data using 50% duty square wave as carrier signal and transmits data through human body. The receiver performs ADC (Analog to Digital Conversion) on carrier signal from human body. In order to figure out the frequency of carrier signal from ADC results, we applied zero-crossing algorithm which is used to detect the edge characteristic in computer vision. Experiment results shows that digital data modulated as square wave can be successfully transmitted through human body by applying the proposed architecture of a 1ch GPIO as a transmitter and 1ch ADC for as a receiver. Also, this paper proposes 1 bit error correction technique for reliable IBC. This technique performs error correction by utilizing the feature that carrier signal has 50% duty ratio. When 1 bit error correction technique is applied, the byte error rate at receiver side is improved around 3.5% compared to that not applied.

A Study on the Implementation of the DC Characteristic Measurement System for Semiconductor Devices (반도체 소자의 직류특성 측정 시스템의 구현에 관한 연구)

  • Park, In-Kyu;Shim, Tae-Eun;Jeong, Hae-Yong;Kim, Jae-Chul;Park, Jong-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.10
    • /
    • pp.837-842
    • /
    • 2001
  • In this paper, we design and implement the DC characteristic measurement system for semiconductor devices. The proposed system is composed of 4 SMU(Source and Measure Unit) channels. Various efforts in hardware and software have been made to reduce the measurement errors. Internal and external sources of errors in measurement system especially in pA range measurement have been identified and removed. Also, various digital signal processing techniques are developed. Calibration is executed under the control of microprocessor periodically. Experimental results show that the implemented system can measure the DC characteristic of semiconductor devices with less than 0.2% error in various voltage and current source/measurement range.

  • PDF

FIB Machining Characteristic Analysis according to $Ga^+$ Ion Beam Current (집속이온빔의 전류변화에 따른 미세가공 특성분석)

  • Kang, Eun-Goo;Choi, Byeong-Yeol;Hong, Won-Pyo;Lee, Seok-Woo;Choi, Hon-Zong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.58-63
    • /
    • 2006
  • FIB equipment can perform sputtering and chemical vapor deposition simultaneously. It is very advantageously used to fabricate a micro structure part having 3D shape because the minimum beam size of ${\Phi}10nm$ and smaller is available. Since general FIB uses very short wavelength and extremely high energy, it can directly make a micro structure less than $1{\mu}m$. As a result, FIB has been probability in manufacturing high performance micro devices and high precision micro structures. Until now, FIB has been commonly used as a very powerful tool in the semiconductor industry. It is mainly used for mask repair, device correction, failure analysis, IC error correction, etc. In this paper FIB-Sputtering and FIB-CVD characteristic analysis were carried out according to $Ga^+$ ion beam current that is very important parameter for minimizing the pattern size and maximizing the yield. Also, for FIB-Sputtering burr caused by redeposition of the substrate characteristic analysis was carried out.