• Title/Summary/Keyword: Equivalent Source Method

Search Result 183, Processing Time 0.029 seconds

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

A Case Study to Estimate the Greenhouse-Gas Mitigation Potential on Rice Production System in Farming without Agricultural Chemicals

  • Lee, Jong-Sik;Ryu, Jong-Hee;Jeong, Hyun-Cheol;Choi, Eun-Jung;Kim, Gun-Yeob
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.374-380
    • /
    • 2014
  • To estimate greenhouse gas (GHG) emission, the inventory of rice cultivation at the farming without agricultural chemicals was established from farmers in Gunsan, Jeonbuk province in 2011~2012. The objectives of this study were to calculate carbon footprint and analyse the major factor of GHGs. To do this, we carried out a sensitivity analysis using the analyzed main factors of GHGs and estimated the mitigation potential of GHGs. Also we suggested agricultural methods to reduce GHGs that can be appled by farmers at this region. At the farming system without agricultural chemicals, carbon footprint of rice production unit of 1 kg was 2.15 kg $CO_2.-eq.kg^{-1}$. Although the amount of carbon dioxide ($CO_2$) emission was the largest among GHGs, methane ($CH_4$) emission had the highest contribution to carbon footprint on rice production system when it was converted to carbon dioxide equivalent ($CO_2-eq.$) multiplied by the global warming potential (GWP). Main source of $CO_2$ emission in the rice farming system without agricultural chemicals was combustion of fossil fuels used by agricultural machinery. Most of the $CH_4$ was emitted during rice cultivation practice and its major emission factor was flooded paddy field in anaerobic condition. Also, most of the $N_2O$ was emitted from rice cultivation process. Major sources of the $N_2O$ emission was application of fertilizer such as compound fertilizer. As a result of sensitivity analysis in energy consumption, diesel had the highest sensitivity among the energy inputs. With the reduction of diesel consumption by 10%, it was estimated that $CO_2$ potential reduction was about 2.0%. With reducing application rate of compound fertilizer by 10%, the potential reduction was calculated that $CO_2$ and $N_2O$ could be reduced by 0.5% and 0.9%, respectively. At the condition of 10% reduction of silicate and compost, $CO_2$ and $CH_4$ could be reduced by 1.5% and 1.6%, respectively. With 8 days more drainage than the ordinary practice, $CH_4$ emission could be reduced by about 4.5%. Drainage and diesel consumption were the main sources having the largest effect on the GHG reduction at the farming system without agricultural chemicals. Based on the above results, we suggest that no-tillage and midsummer drainage could be a method to decrease GHG emissions from rice production system.

A System Model of Iterative Image Reconstruction for High Sensitivity Collimator in SPECT (SPECT용 고민감도 콜리메이터를 위한 반복적 영상재구성방법의 시스템 모델 개발)

  • Bae, Seung-Bin;Lee, Hak-Jae;Kim, Young-Kwon;Kim, You-Hyun;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • Low energy high resolution (LEHR) collimator is the most widely used collimator in SPECT imaging. LEHR has an advantage in terms of image resolution but has a difficulty in acquiring high sensitivity due to the narrow hole size and long septa height. Throughput in SPECT can be improved by increasing counts per second with the use of high sensitivity collimators. The purpose of this study is to develop a system model in iterative image reconstruction to recover the resolution degradation caused by high sensitivity collimators with bigger hole size. We used fan-beam model instead of parallel-beam model for calculation of detection probabilities to accurately model the high sensitivity collimator with wider holes. In addition the weight factors were calculated and applied onto the probabilities as a function of incident angle of incoming photons and distance from source to the collimator surface. The proposed system model resulted in the equivalent performance with the same counts (i.e. in shortened acquisition time) and improved image quality in the same acquisition time. The proposed method can be effectively applied for resolution improvement of pixel collimator of next generation solid state detectors.

Characteristic Evaluation of Exposed Dose with NORM added Consumer Product based on ICRP Reference Phantom (ICRP 기준팬텀 기반의 천연방사성핵종이 포함된 가공제품 사용으로 인한 피폭선량 특성 평가)

  • Yoo, Do Hyeon;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.159-167
    • /
    • 2014
  • In Korea, July 2012, the law as called 'Act on Safety Control of Radioactive Rays Around Living Environment' was implemented to control the consumer product containing Naturally Occurring Radioactive Material (NORM), but, there are no appropriate database and effective dose calculation system. The aim of this study was to develop evaluation technique of the exposure dose with the use of the consumer products containing NORM and to understand the characteristics of the exposed dose according to the radiation type and energy. For the evaluate of exposure dose, the ICRP reference phantom was simulated by the MCNPX code based on Monte Carlo method, and the minimum, medium, maximum energy of alphas, betas, gammas from the representative NORM of Uranium decay series were used as the source term in the simulation. The annual effective doses were calculated by the exposure scenario of the consumer product usage time and position. Short range of the alpha and beta rays are mostly delivered the dose to the skin. On the other hand, the gamma rays mostly delivered the similar dose to all of the organs. The results of the annual effective dose with $1Bq{\cdot}g^{-1}$ radioactive stone-bed and 10% radioactive concentration were employed with the usage time of 7 hours 50 minute per day, the maximum annual effective dose of alphas, betas, gammas were calculated 0.0222, 0.0836, $0.0101mSv{\cdot}y^{-1}$, respectively.

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Analysis of Antioxidant Activity and Serotonin Derivatives in Safflower (Carthamus tinctorius L.) Germplasm Collected from Five Countries (국외 수집 홍화 유전자원의 항산화 활성 및 세로토닌 유도체 함량 분석)

  • Jung, Yi Jin;Assefa, Awraris Derbie;Lee, Jae Eun;Lee, Ho Sun;Rhee, Ju Hee;Sung, Jung Sook
    • Korean Journal of Plant Resources
    • /
    • v.32 no.5
    • /
    • pp.423-432
    • /
    • 2019
  • In order to select potential plant resources as functional materials and natural antioxidants, we evaluated antioxidant activity and serotonin derivatives of safflower germplasm collected from five countries. N-(p-Coumaroyl) serotonin (CS) and N-feruloylserotonin (FS) were analyzed by using Ultra Performance Liquid Chromatography (UPLC). Total polyphenol content (TPC) was determined by Folin-Ciocalteu method and antioxidant activities were estimated by 2,2-diphenyl-1-picryl-hydrazil (DPPH), 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) diammonium salt (ABTS), Ferric reducing antioxidant power (FRAP) and Reducing power (RP) assays. The TPC showed a range of 28.25 to $90.53{\mu}g$ gallic acid equivalent (GAE)/mg dried extract (DE). DPPH, ABTS, FRAP and RP assay were in the range of 18.76 to 93.98, 48.91 to 163.73, 3.80 to 132.29 and 26.32 to $80.08{\mu}g$ ascorbic acid equivalent (ASCE)/mg DE, respectively. Among the five countries, safflower seed collected from Iran had the highest levels of serotonin derivatives and antioxidant activities than other countries (p<0.05). CS showed high correlation with TPC, ABTS and DPPH (r=0.673,0.727,0.820), and FS showed high correlation with DPPH (r=0.740). Accessions IT321214 and IT321215 could be useful for development of new functional materials and could be used as a source of valuable natural antioxidant materials.

A basic study on explosion pressure of hydrogen tank for hydrogen fueled vehicles in road tunnels (도로터널에서 수소 연료차 수소탱크 폭발시 폭발압력에 대한 기초적 연구)

  • Ryu, Ji-Oh;Ahn, Sang-Ho;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.517-534
    • /
    • 2021
  • Hydrogen fuel is emerging as an new energy source to replace fossil fuels in that it can solve environmental pollution problems and reduce energy imbalance and cost. Since hydrogen is eco-friendly but highly explosive, there is a high concern about fire and explosion accidents of hydrogen fueled vehicles. In particular, in semi-enclosed spaces such as tunnels, the risk is predicted to increase. Therefore, this study was conducted on the applicability of the equivalent TNT model and the numerical analysis method to evaluate the hydrogen explosion pressure in the tunnel. In comparison and review of the explosion pressure of 6 equivalent TNT models and Weyandt's experimental results, the Henrych equation was found to be the closest with a deviation of 13.6%. As a result of examining the effect of hydrogen tank capacity (52, 72, 156 L) and tunnel cross-section (40.5, 54, 72, 95 m2) on the explosion pressure using numerical analysis, the explosion pressure wave in the tunnel initially it propagates in a hemispherical shape as in open space. Furthermore, when it passes the certain distance it is transformed a plane wave and propagates at a very gradual decay rate. The Henrych equation agrees well with the numerical analysis results in the section where the explosion pressure is rapidly decreasing, but it is significantly underestimated after the explosion pressure wave is transformed into a plane wave. In case of same hydrogen tank capacity, an explosion pressure decreases as the tunnel cross-sectional area increases, and in case of the same cross-sectional area, the explosion pressure increases by about 2.5 times if the hydrogen tank capacity increases from 52 L to 156 L. As a result of the evaluation of the limiting distance affecting the human body, when a 52 L hydrogen tank explodes, the limiting distance to death was estimated to be about 3 m, and the limiting distance to serious injury was estimated to be 28.5~35.8 m.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy (고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구)

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.290-297
    • /
    • 2009
  • In case of radiation treatment using small field high-energy photon beams, an accurate dosimetry is a challenging task because of dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, and non-uniformity between the detector and the phantom materials. In this study, the absorbed dose in the phantom was measured by using an ion chamber and a diode detector widely used in clinics. $GAFCHROMIC^{(R)}$ EBT films composed of water equivalent materials was also evaluated as a small field detector and compared with ionchamber and diode detectors. The output factors at 10 cm depth of a solid phantom located 100 cm from the 6 MV linear accelerator (Varian, 6 EX) source were measured for 6 field sizes ($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$ and $0.5{\times}0.5\;cm^2$). As a result, from $5{\times}5\;cm^2$ to $1.5{\times}1.5\;cm^2$ field sizes, absorbed doses from three detectors were accurately identified within 1%. Wheres, the ion chamber underestimated dose compared to other detectors in the field sizes less than $1{\times}1\;cm^2$. In order to correct the observed underestimation, a convolution method was employed to eliminate the volume averaging effect of an ion chamber. Finally, in $1{\times}1\;cm^2$ field the absorbed dose with a diode detector was about 3% higher than that with the EBT film while the dose with the ion chamber after volume correction was 1% lower. For $0.5{\times}0.5\;cm^2$ field, the dose with the diode detector was 1% larger than that with the EBT film while dose with volume corrected ionization chamber was 7% lower. In conclusion, the possibility of $GAFCHROMIC^{(R)}$ EBT film as an small field dosimeter was tested and further investigation will be proceed using Monte Calro simulation.

  • PDF

Underpricing of Initial Offerings and the Efficiency of Investments (신주(新株)의 저가상장현상(低價上場現象)과 투자(投資)의 효율성(效率成)에 대한 연구(硏究))

  • Nam, Il-chong
    • KDI Journal of Economic Policy
    • /
    • v.12 no.2
    • /
    • pp.95-120
    • /
    • 1990
  • The underpricing of new shares of a firm that are offered to the public for the first time (initial offerings) is well known and has puzzled financial economists for a long time since it seems at odds with the optimal behavior of the owners of issuing firms. Past attempts by financial economists to explain this phenomenon have not been successful in the sense that the explanations given by them are either inconsistent with the equilibrium theory or implausible. Approaches by such authors as Welch or Allen and Faulhaber are no exceptions. In this paper, we develop a signalling model of capital investment to explain the underpricing phenomenon and also analyze the efficiency of investment. The model focuses on the information asymmetry between the owners of issuing firms and general investors. We consider a firm that has been owned and operated by a single owner and that has a profitable project but has no capital to develop it. The profit from the project depends on the capital invested in the project as well as a profitability parameter. The model also assumes that the financial market is represented by a single investor who maximizes the expected wealth. The owner has superior information as to the value of the firm to investors in the sense that it knows the true value of the parameter while investors have only a probability distribution about the parameter. The owner offers the representative investor a fraction of the ownership of the firm in return for a certain amount of investment in the firm. This offer condition is equivalent to the usual offer condition consisting of the number of issues to sell and the unit price of a share. Thus, the model is a signalling game. Using Kreps' criterion as the solution concept, we obtained an essentially unique separating equilibrium offer condition. Analysis of this separating equilibrium shows that the owner of the firm with high profitability chooses an offer condition that raises an amount of capital that is short of the amount that maximizes the potential profit from the project. It also reveals that the fraction of the ownership of the firm that the representative investor receives from the owner of the highly profitable firm in return for its investment has a value that exceeds the investment. In other words, the initial offering in the model is underpriced when the profitability of the firm is high. The source of underpricing and underinvestment is the signalling activity by the owner of the highly profitable firm who attempts to convince investors that his firm has a highly profitable project by choosing an offer condition that cannot be imitated by the owner of a firm with low profitability. Thus, we obtained two main results. First, underpricing is a result of a signalling activity by the owner of a firm with high profitability when there exists information asymmetry between the owner of the issuing firm and investors. Second, such information asymmetry also leads to underinvestment in a highly profitable project. Those results clearly show the underpricing entails underinvestment and that information asymmetry leads to a social cost as well as a private cost. The above results are quite general in the sense that they are based upon a neoclassical profit function and full rationality of economic agents. We believe that the results of this paper can be used as a basis for further research on the capital investment process. For instance, one can view the results of this paper as a subgame equilibrium in a larger game in which a firm chooses among diverse ways to raise capital. In addition, the method used in this paper can be used in analyzing a wide range of problems arising from information asymmetry that the Korean financial market faces.

  • PDF