Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

Sensitivity Analysis of the CMB Modeling Results by Considering Photochemical Degradation of Polycyclic Aromatic Hydrocarbons (PAHs) in the Seoul atmosphere (서울 대기에서 PAHs 광화학반응을 고려한 CMB 수용모델 결과 검토)

  • Cho, Ye Seul;Jung, Da Bin;Kim, In Sun;Lee, Ji Yi;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Several studies have been carried out on the source contribution of the particulate Polycyclic Aromatic Hydrocarbons (PAHs) over Seoul by using the Chemical Mass Balance Model (CMB)(Lee and Kim, 2007; Kim et al., 2013). To confirm the validity of the modeling results, the modified model employing a photochemical loss rate along with varying residence times and the standard model that considers no loss were compared. It was found that by considering the photochemical loss rate, a better performance was obtained as compared to those obtained from the standard model in the CMB calculation. The modified model estimated higher contributions from coke oven, transportation, and biomass burning by 4 to 8%. However, the order of the relative importance of major sources was not changed, coke oven followed by transportation and biomass burning. Thus, it was concluded that the standard CMB model results are reliable for identifying the relative importance of major sources.

A Study on Status of Domestic Machine Tools Remanufacturing Technology Development and Improvement of Standard Process (국내 공작기계 재제조 기술개발 현황 및 표준공정 개선방안 연구)

  • Sung-woo Shin;Sang-Seok Seol;Young-Hwa Roh;Hyun-Su Kim;Min-Seong Park;Won-Jee Chung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.415-424
    • /
    • 2024
  • This study analyzes trends and characteristics of the machine tool remanufacturing industry and proposes a standard process that considers environmental impact assessment during the remanufacturing process. First, trends in remanufacturing and environmental regulations are reviewed. And the current status of the machine tool remanufacturing industry and cases of national R&D projects related to machine tools are analyzed. Machine tool remanufacturing has a high resource saving effect, and remanufacturing is carried out as a finished product rather than as a part. And the scope of remanufacturing work is very wide due to the performance improvement of the machine and the addition of features. In order for the machine tool remanufacturing industry to be competitive, it is necessary to create products with high added value. In addition, in order to respond to international environmental regulations, it is necessary to secure related data by conducting an environmental impact assessment together during remanufacturing.

A Study on The Comparison of Mechanical Property Between The Staggered Stud Wood Wall and The Standard Wood Frame Wall (일반벽체와 교호 샛기둥 벽체의 역학적 성능 비교 연구)

  • Shim, Jae-Kwang;Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.640-649
    • /
    • 2017
  • A comparative research on the traditional standard wood walls and other light-frame wood walls is necessary to expand the base of wooden buildings and improve consumer satisfaction. Therefore, in this research we looked for new possibilities through comparison of performance between standard wood wall and newly presented staggered stud wood wall. First, the strength characteristics of staggered stud wood walls were evaluated and the those of standard wood walls were compared. The ultimate load of the standard wall was larger than that of the staggered stud wood wall, because the cross section of the wood making up the standard wood wall was larger than that of the staggered stud wood wall. However, the statistical analysis between the two groups didn't showed a significance of 95% confidence level. This means that, staggered stud wood walls have shown the possibility of replacing the standard wood wall. Because the cross-section of the stud in the staggered stud wood walls is smaller than that of the standard wall, the material can be saved. Therefore, staggerd wood stud wall is judged to be more economical than the standard wall. In addition, since the area of the insulation also increases, improvement of the heat bridge is also expected.

Application of SOPs (Standard Operating Procedures) in National Environmental Specimen Bank (국가환경시료은행의 표준운영절차 적용)

  • Kim, Myungjin;Lee, Jangho;Choi, Taeyoung;Han, Areum;Song, Kyohong;Lee, Eugene;Lee, Jongchun
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.327-338
    • /
    • 2012
  • Environmental specimen banks provide the baselines for the scientists and decision makers to do research using the past and present specimens to expect the possible contaminant implications of the future. Many chemicals that are considered harmless now but not found may be found and pose threats in the future. Collected specimens of animals and plants should be conserved without contamination for future analysis. To ensure the availability of samples for the retrospective analysis, the establishment and maintenance of specimen banks in the developing and developed nations has become absolutely necessary. National Environmental Specimen Bank (NESB) established at National Institute of Environmental Research (NIER) in 2009. For the application of NESB, several activities such as standard operating procedures (SOPs) development have been prepared. This study applied the guidelines for sampling and sample treatment of five environmental specimens which had been prepared from 2007 to 2009. The target species were shoots of red pine and Korean pine, leaves of Mongolian oak, eggs of domestic pigeon and muscles and livers of common carp. The NESB will enhance the quality of environmental assessment and environmental monitoring based on real time and retrospective analysis.

Reliability Analysis of Auto-Connector in Use-condition (사용 조건하에서의 자동차용 커넥터 신뢰성 분석)

  • 김종걸;김진환
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.129-136
    • /
    • 2004
  • Environmental factors for automotive consist of temperature, humidity, vibration(sine & random), gas, an electrical load and so on. These environmental factors are impressed in a automotive. Dependability is essential requirement in many electronic parts. Among components of automotive, the connector connecting electrical signals is one of the most important parts. Automotive -connector is inspected according to each manufacturer's test standard in which dependability should be considered. This paper aims to verify that current test standard is suitable for dependability, and present an inductive life test for automotive connector based on the field data in use-condition.

  • PDF

Production of Standard Sample for Quality Control of Total Coliform (총대장균군 측정의 정도관리에 적합한 균주의 조제)

  • Kim, Ju-Young;Seo, Eun-Young;Kim, Mi-Ree;Jeon, Nam-Hui;Chung, Hyen-Mi;Kim, Myeong-Woon;Ahn, Tea-Seok
    • Korean Journal of Microbiology
    • /
    • v.44 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Standard sample for quality control of total coliform measurement was procured by addition of nalidixic acid and cephalexin as bacteriostatic agents to Escherichia coli cultured broth. After making the standard sample, the number of E. coli was measured by fluorescence microscopic count method and plate count method by 12 hr interval. The numbers of E. coli remained unchanged for at least for 48 hr at room temperature which ranged from 3.5 to $4.2{\times}10^5\;cells/ml$ and from 1.0 to $1.2{\times}10^4\;CFU/ml$ by direct fluorescence microscopic count method and plate count method, respectively. This result suggests that microbial standard sample with bacteriostatic agents of nalidixic acid and cephalexin is usable for quantitative quality control.

A Study on Reduction Effects of Air Pollutant Emissions by Automotive Fuel Standard Reinforcement (자동차연료 기준강화에 따른 대기오염물질 배출량 저감효과)

  • Lim, Cheol-Soo;Hong, Ji-Hyung;Kim, Jeong-Soo;Lee, Jong-Tae;Lim, Yun-Sung;Kim, Sang-Kyu;Jeon, Sang-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.181-190
    • /
    • 2011
  • The air pollutants from vehicle exhaust gas are affected by many factors including fuel qualities, engine and vehicle technologies, driving patterns. In particular, fuel qualities and after-treatment devices could directly affect the emission level of pollutants. The pollutant reduction characteristics that caused by enforced fuel quality standard were analyzed. Three types of test fuel were selected in accordance with Korean automotive fuel standard in 2006, 2009, 2012 and used for vehicle emission test in chassis dynamometer. European COPERT correction equation of fuel impact was considered as reference information to quantify the vehicle emission test results. The contribution rates of exhaust emission by COPERT correction equation showed that aromatic compounds and oxygen contents in gasoline fuel was most important. In case of diesel fuel, cetane index and polycyclic aromatic compounds accounted for the greater part. The exhaust emission effects by COPERT correction equation revealed that CO and VOC was increased 0.86%, 1.57% respectively in after 2009 gasoline when compared to before 2009 gasoline fuel. In case of light-duty diesel vehicle CO, VOC and PM were decreased in range of 3~7%. The result from this study could be provided for developing future fuel standards and be used to fundamental information for Korean clean air act.

Air Pollution History, Regulatory Changes, and Remedial Measures of the Current Regulatory Regimes in Korea (우리나라 대기오염 역사, 규제의 변천, 현행 규제제도의 개선방안)

  • Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.353-368
    • /
    • 2013
  • All Koreans had suffered heavily from municipal and industrial air pollution problems since 1960's to 1980's. However the levels of $SO_2$, CO, and Pb have been dramatically decreased since 1990's due to various air pollutants' reduction policies under the provisions of the 1978 Environmental Preservation Act and the 1990 Air Quality Preservation Act such as increasing the supply of low-sulfur fuel, the use of cleaner fuel, no use of solid fuel, and so on. Even though the national ambient air quality standard has been strengthened to protect public health and welfare, the levels of $NO_2$, $O_3$, and $PM_{10}$ frequently exceed the corresponding standards; for example, only 4 stations (1.7%) out of 239 nationwide monitoring stations satisfied the 24-hr based PM10 standard in 2011. Moreover, upto the present time, since there are serious underlying policies of economism and growth-first which can not be solely solved by the environmental laws, it is difficult to root out undesirable social evils such as public indifference, passive academic activities, complacent government bureaucracy, insufficient social responsibility of enterprise, and radical activities of environmental groups. The paper initially reviewed air pollution history of Korea with surveying various environmental factors affecting in/out-door air pollution in the past Korea. Further this study extensively investigated legal and political changes on air pollution control and management for the last 50 years, and then intensively discussed the present environment-related laws and policies unreasonably enforced in Korea. It is necessary to practically revise many outdated legal policies based on health-oriented thinking and on our current economic levels as well.

Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed- (시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로-)

  • Park, Jinhwan;Kang, Taewoo;Han, Sungwook;Baek, Seunggwon;Kang, Taegu;Yoo, Jechul;Kim, Youngsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.