Abstract

A comparative research on the traditional standard wood walls and other light-frame wood walls is necessary to expand the base of wooden buildings and improve consumer satisfaction. Therefore, in this research we looked for new possibilities through comparison of performance between standard wood wall and newly presented staggered stud wood wall. First, the strength characteristics of staggered stud wood walls were evaluated and the those of standard wood walls were compared. The ultimate load of the standard wall was larger than that of the staggered stud wood wall, because the cross section of the wood making up the standard wood wall was larger than that of the staggered stud wood wall. However, the statistical analysis between the two groups didn't showed a significance of 95% confidence level. This means that, staggered stud wood walls have shown the possibility of replacing the standard wood wall. Because the cross-section of the stud in the staggered stud wood walls is smaller than that of the standard wall, the material can be saved. Therefore, staggerd wood stud wall is judged to be more economical than the standard wall. In addition, since the area of the insulation also increases, improvement of the heat bridge is also expected.

목조건축의 기반을 넓히고 소비자의 만족도를 향상시키기 위해 기존의 일반목조벽체 및 기타 경량목조벽체에 대한 비교 연구가 필요하다. 따라서 본 연구에서는 일반벽체와 개선된 방식인 교호 샛기둥 벽체와의 성능 비교를 통해 새로운 가능성을 찾고자 하였다. 우선 교호 샛기둥 벽체의 강도적 특성을 평가하고 일반벽체의 강도적 특성을 비교하였다. 일반벽체를 구성하는 목재의 단면이 교호 샛기둥 벽체보다 크기 때문에 일반벽체의 최대하중이 교호 샛기둥 벽체 보다 크게 나타났다. 하지만, 두 그룹간의 통계분석에 의하면 95% 신뢰 수준에서 유의성을 보이지 않아, 교호 샛기둥 벽체는 일반벽체를 대체할 수 있는 가능성을 보여주었다. 교호 샛기둥 벽채는 샛기둥의 단면이 일반벽체보다 작기 때문에 재료를 절약할 수 있어서 일반벽체보다 더 경제적이라고 판단된다. 또한 단열재의 면적 또한 증가하므로 열교 현상의 개선도 기대된다.

Keywords

References

  1. Brown, W.C., Bomberg, M.T., Ullett, J.M., Rasmussen, J. 1993. Measured Thermal Resistance of Frame Walls with Defects in the Installation of Mineral Fibre Insulation. Journal of Building Physics 16(4): 318-339. https://doi.org/10.1177/109719639301600404
  2. Cole, R.J. 1998. Energy and green house gas emissions associated with the construction of alternative structural systems. Building and Environment 34(3): 335-348. https://doi.org/10.1016/S0360-1323(98)00020-1
  3. Kim, G.C., Lee, M.H. 2015. A study on the insulating property of the complex insulating wall. 2015 Proceedings of the korean society of wood science and technology annual meeting. 252-253.
  4. Kim, G.C., Lee, M.H. 2016. A study on the complex insulating wall confront enhanced thermal transmittance. 2016 Proceedings of the korean society of wood science and technology annual meeting. 218-219.
  5. Kim, G.C., Shim, J.K. 2015. A mechanical property of the staggered stud wooden wall. 2015 Proceedings of the korean society of wood science and technology annual meeting. 254-255.
  6. Kim, G.C., Shim, J.K. 2016. A study on the structural performance of complex insulating wall. 2016 Proceedings of the korean society of wood science and technology annual meeting. 224-225.
  7. Kim, G.C., Shim, J.K. 2016. Design guide on the wooden frame house. Chonbuk National University Press.
  8. KS F 2198. 2004. Determination of density and specific gravity of wood, Korean Standard Association.
  9. KS F 2199. 2004. Determination of moisture content of wood, Korean Standard Association.
  10. KS F 2206. 2014. Method of compression test for wood. Korean Standard Association.
  11. Molit (Ministry if land, infrastructure and transport). 2015, Building permits of construction in korea.
  12. Patton-Mallory, M., Wolfe, R.W., Soltis, L.A., Gutkowski, R.M. 1985. Light-frame shear wall length and opening effects. Journal of Structural Engineering ASCE 111(10): 2227-2239. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:10(2227)
  13. Sherwood, G.E. 1987. Condensation Potential in Wood-Frame walls, U.S. Forest Products Laboratory, Madison, WI.
  14. Shim, J.K. 2016. A study on the comparison of mechanical property between the staggered stud wooden wall and the standard wooden frame wall. Master's. Thesis, Chonbuk National University.
  15. T Rodriguez-Nikl, et al. 2015. Seismic laboratory testing of energy-efficient, staggered-stud, wood-frame shear walls. Journal of Structural Engineering 141(3): 1-8.