• Title/Summary/Keyword: Environment conversion factor

Search Result 63, Processing Time 0.028 seconds

Method of Estimating Environment Conversion Factor Analyzing Environment Factors of MIL-HDBK-217F (MIL-HDBK-217F의 환경인자 분석을 통한 환경변환계수 추정)

  • Jeong, Da-Un;Yun, Hui-Sung;Lee, Eun-Hak;Kwon, Dong-Soo;Lee, Seung-Hun
    • Journal of Applied Reliability
    • /
    • v.11 no.2
    • /
    • pp.141-149
    • /
    • 2011
  • Environment Conversion Factors, which are stipulated in System Reliability Toolkit, have a lot of advantages once applied in a reliability data handbook such as NPRD-95, during the process of reliability prediction. However, the factors have a restriction in their applications because they don't deal with a few environments, e.g., Missile Launch (ML). In this study, environment factors of various components from MIL-HDBK-217F were analyzed to address this problem. Statistical computations showed that converting from Airborne Rotary Wing (ARW) to Missile Launch (ML) was the most coherent by comparing coefficient of determination. In addition, conversion factors from System Reliability Toolkit and those from the statistical calculations were evaluated in terms of their similarities.

Application of Margin of Safety Considering Regional Characteristics for the Management of Total Maximum Daily Loads (지역특성을 고려한 수질오염총량관리 안전부하량 적용)

  • Park, Jun Dae;Oh, Seung Young;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The allocation of margin of safety (MOS) at a uniform rate to all areas of the unit watershed makes it very difficult to keep the load allotment stable in the area for lack of reduction measures like forest land. This study developed an equation to calculate margin of safety differentially according to the regional characteristics. The equation was formulated on the basis of the regional characteristic factors such as a load contribution factor for land use type and a site conversion factor for the unit watershed. The load contribution factor represents a contribution of loads from a particular land use. The site conversion factor was derived from the site conversion ratio of a unit watershed. Margin of safety for the non-point pollution load in the land use sector decreased by 20~25% in three river basins. The margin of safety in the unit watersheds with low site occupation ratios decreased in high rate, while in the unit watersheds with large urban area decreased in low rate. With the application of the differential margin of safety considering regional characteristics, not only the reduction of pollution loads can become lighter but also it can be easier to develop plans for Total Maximum Daily Loads (TMDLs) even where the reduction measures are not available.

Validation of a Model for Estimating Individual External Dose Based on Ambient Dose Equivalent and Life Patterns

  • Sato, Rina;Yoshimura, Kazuya;Sanada, Yukihisa;Sato, Tetsuro
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. Materials and Methods: The model estimates effective doses based on the integrated ambient dose equivalent (H*(10)) and life patterns, considering a dose reduction factor to estimate the indoor H*(10) and a conversion factor from H*(10) to the effective dose. Because personal dose equivalent (Hp(10)) has been reported to agree well with the effective dose after the FDNPS accident, this study validates the model's accuracy by comparing the estimated effective doses with Hp(10). The Hp(10) and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. Results and Discussion: The estimated effective doses correlated significantly with Hp(10); however, the estimated effective doses were lower than Hp(10) for indoor sites. A comparison with the measured indoor H*(10) showed that the estimated indoor H*(10) was not underestimated. However, the Hp(10) to H*(10) ratio indoors, which corresponds to the practical conversion factor from H*(10) to the effective dose, was significantly larger than the same ratio outdoors, meaning that the conversion factor of 0.6 is not appropriate for indoors due to the changes in irradiation geometry and gamma spectra. This could have led to a lower effective dose than Hp(10). Conclusion: The estimated effective doses correlated significantly with Hp(10), demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose indoors could be because the conversion factor did not reflect the actual environment.

A Study on The Conversion Factor between Heterogeneous DBMS for Cloud Migration

  • Joonyoung Ahn;Kijung Ryu;Changik Oh;Taekryong Han;Heewon Kim;Dongho Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.8
    • /
    • pp.2450-2463
    • /
    • 2024
  • Many legacy information systems are currently being clouded. This is due to the advantage of being able to respond flexibly to the changes in user needs and system environment while reducing the initial investment cost of IT infrastructure such as servers and storage. The infrastructure of the information system migrated to the cloud is being integrated through the API connections, while being subdivided by using MSA (Micro Service Architecture) internally. DBMS (Database Management System) is also becoming larger after cloud migration. Scale calculation in most layers of the application architecture can be measured and calculated from auto-scaling perspective, but the method of hardware scale calculation for DBMS has not been established as standardized methodology. If there is an error in hardware scale calculation of DBMS, problems such as poor performance of the information system or excessive auto-scaling may occur. In addition, evaluating hardware size is more crucial because it also affects the financial cost of the migration. CPU is the factor that has the greatest influence on hardware scale calculation of DBMS. Therefore, this paper aims to calculate the conversion factor for CPU scale calculation that will facilitate the cloud migration between heterogeneous DBMS. In order to do that, we utilize the concept and definition of hardware capacity planning and scale calculation in the on-premise information system. The methods to calculate the conversion factor using TPC-H tests are proposed and verified. In the future, further research and testing should be conducted on the size of the segmented CPU and more heterogeneous DBMS to demonstrate the effectiveness of the proposed test model.

High Alloying Degree of Carbon Supported Pt-Ru Alloy Nanoparticles Applying Anhydrous Ethanol as a Solvent

  • Choi, Kwang-Hyun;Lee, Kug-Seung;Jeon, Tae-Yeol;Park, Hee-Young;Jung, Nam-Gee;Chung, Young-Hoon;Sung, Yung-Eun
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Alloying degree is an important structural factor of PtRu catalysts for direct methanol fuel cells (DMFC). In this work, carbon supported PtRu catalysts were synthesized by reduction method using anhydrous ethanol as a solvent and $NaBH_4$ as a reducing agent. Using anhydrous ethanol as a solvent resulted in high alloying degree and good dispersion. The morphological structure and crystallanity of synthesized catalysts were characterized by X-ray diffraction (XRD), high resolution transmission electron microscope (HR-TEM). CO stripping and methanol oxidation reaction were measured. Due to high alloying degree catalyst prepared in anhydrous ethanol, exhibited low onset potential for methanol oxidation and negative peak shift of CO oxidation than commercial sample. Consequently, samples, applying ethanol as a solvent, exhibited not only enhanced CO oxidation, but also increased methanol oxidation reaction (MOR) activity compared with commercial PtRu/C (40 wt%, E-tek) and 40 wt% PtRu/C prepared in water solution.

A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul (서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Oh, Seokryul;Kim, Iksoo;Shin, Jinho;Eo, Soomi;Jung, Kweon;Lee, Jinsook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator (산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화)

  • 김만구;권영진;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

Optimal Rotor Blade Design for Tidal In-stream Energy (조류발전용 로터 블레이드의 최적 형상 설계)

  • Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.75-82
    • /
    • 2011
  • Marine current energy is one of the most interesting renewable and clean energy resources that have been less exploited. Especially, Korea has worldwide outstanding tidal current energy resources and it is highly required to develop tidal in-stream energy conversion system in coastal area. The objective of study is to investigate harnessing techniques of tidal current energy and to design the a 100 kW horizontal axis tidal turbine using blade element momentum theory with Prandtl's tip loss factor for optimal design procedures. In addition, Influence of Prandtl's tip loss factor at local blade positions as a function of tip speed ratio was studied, and the analysed results showed that power coefficient of designed rotor blade using NACA 63812 was 0.49 at rated tip speed ratio.