An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source (공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구)

  • SOON YOUNG JEONG
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy (신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구)

  • JEONG, SOON YOUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.6
    • /
    • pp.630-636
    • /
    • 2020
  • This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

Investigation on the Wave Power Resources on the East Coast of Korea Based on Field Measurement Data (실측자료에 근거한 동해안 파력 부존량 검토)

  • Jeong, Weon-Mu;Oh, Sang-Ho;Lee, Dal-Soo;Lee, Dong-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.630-634
    • /
    • 2007
  • In the past, the use of wave energy has mainly been focused on conversion of large wave energy resources in the far offshore areas. However, with the technological improvement of converting wave energy into electricity, the energy resources at much shallow waters are now considered as a site for possible installation of the devices that obtain energy from the waves. In this respect, the wave energy resources on the east coast of Korea, where the sea is milder than the open ocean, were investigated using the field measurement data obtained at three different locations along the coast. For all the locations, the wave power was greater in winter season, compared to summer season. The estimated wave power varied from 2 to 4.5 kW/m on average, depending on the measurement locations.

  • PDF

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

Quantitative Measurement of Ethane Using Mid-infrared Cavity Ring-down Spectroscopy

  • Yonghee Kim;Byung Jae Chun;Lim Lee;Kwang-Hoon Ko;Seung-Kyu Park;Taek-Soo Kim;Hyunmin Park
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.457-462
    • /
    • 2023
  • Quantitative measurement of trace ethane is important in environmental science and biomedical applications. For these applications, we typically require a few tens of part-per-trillion level measurement sensitivity. To measure trace-level ethane, we constructed a cavity ring-down spectroscopy setup in the 3.37 ㎛ mid-infrared wavelength range, which is applicable to multi-species chemical analysis. We demonstrated that the detection limit of ethane is approximately 300 parts per trillion, and the measured concentration is in agreement with the amounts of the injected sample. We expect that these results can be applied to the chemical analysis of ethane and applications such as breath test equipment.

An Evaluation on Energy Recovery Performance of the Ventilation System in Multi-Residential Building by Field Measurement (실험을 통한 공동주택 환기시스템의 실제 운전 시 전열교환성능 검토)

  • Choi, Younhee;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-73
    • /
    • 2017
  • Recently, energy recovery ventilators (ERVs) have been installed for energy saving in many multi-residential buildings in Korea. The performance of the heat exchanger of an ERV is analyzed in this study under specific indoor and outdoor conditions in a test-cell measurement. However, the performance of the heat exchanger varies according to the indoor and outdoor condition. In this study, the performance of energy recovery of the ventilation system was therefore analyzed in actual weather conditions using field measurement. Experiments were conducted under winter conditions in a multi-residential building for 20 days. Based on the measurement results, the characteristics of sensible heat and latent heat exchange rates were analyzed.

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module (PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Comparative Validation of WindCube LIDAR and Remtech SODAR for Wind Resource Assessment - Remote Sensing Campaign at Pohang Accelerator Laboratory (풍력자원평가용 윈드큐브 라이다와 렘텍 소다의 비교.검증 - 포항가속기 원격탐사 캠페인)

  • Kim, Hyun-Goo;Chyng, Chin-Wha;An, Hae-Joon;Ji, Yeong-Mi
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.63-71
    • /
    • 2011
  • The remote-sensng campaign was performed at the Pohang Accelerator Laboratory where is located in a basin 6km inland from Yeongil Bay. The campaign aimed uncertainty assessment of Remtech PA0 SODAR through a mutual comparison with WindCube LIDAR, the remote-sensing equipment for wind resource assessment. The joint observation was carried out by changing the setup for measurement heights three times over two months. The LIDAR measurement was assumed as the reference and the uncertainty of SODAR measurement was quantitatively assessed. Compared with LIDAR, the data availability of SODAR was about half. The wind speed measurement was fitted to a slope of 0.94 and $R^2$ of 0.79 to the LIDAR measurement. However, the relative standard deviation was about 17% under 150m above ground level. Therefore, the Remtech PA0 SODAR is judged to be unsuitable for the evaluation of wind resource assessment and wind turbine performance test, which require accuracy of measurement.