• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 868, Processing Time 0.036 seconds

Evaluation Study on the Effects of $NO_x$ Reduction Techniques on the Performance and the Emission Characteristics of Medium Size Gasification Combined Cycle Plant (중급 규모 가스화 복합발전 플랜트의 $NO_x$ 저감 방식이 성능 및 환경특성에 미치는 영향에 관한 평가 연구)

  • Lee, Chan;Seo, Je-Young
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.363-369
    • /
    • 2001
  • Process design and performance evaluation were made for medium-size gasification combined/cogeneration plant. Based on the designed plant process configuration, the effects of $NO_x$ reduction techniques on the $NO_x$ emission, the power output, the efficiency and the stability of plant are investigated by applying various $NO_x$ reduction methods such as unsaturated/saturated nitrogen injection and fuel saturation of gas turbine combustor. The $NO_x$ reduction by nitrogen injection is more remarkable than that by fuel saturation, and its effect can be more enhanced by using saturated nitrogen. In addition, the applications of $NO_x$ reduction techniques accompany the improvement of plant power output and efficiency with the decrease of $NO_x$ emission, while it can cause unstable gas turbine operation.

  • PDF

Comparative Evaluation of Surface Temperature among Rooftop Colors of Flat Roof Building Models : Towards Performance Evaluation of Cool Roof (평지붕 건물 축소모형의 지붕색에 대한 표면 온도의 비교평가: 쿨루프 성능평가 차원에서)

  • Ryu, Taek Hyoung;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.83-91
    • /
    • 2013
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. It is specifically proposed that the changing trends of rooftop surface temperature in the flat roof building model could be used effectively as an indicator to reduced cooling load reduced by cool roof since it can present stable temperature record, that is not influenced according to the nearby physical as well as human variables. The temperature of cool roof in summer was lower around $20^{\circ}C$, compared to the general roofs. Such a seasonal or daily comparative study for rooftop temperature in the building model will highlight that the cool roof efficiency could be calculated in much area-wide context according to rooftop color distribution in urban residential area. It is anticipated that this research output could be used as a valuable reference in identifying energy saving by cool roof since an objective monitoring has been proposed based on the rooftop temperature in the building model, fully quantitative performance of thermal infrared image.

A Study on the Coincidences Between Group Traits and Personal Traits upon the Job Stress (개인 및 조직 성향의 적합도와 직무스트레스와의 상관성에 관한 연구)

  • Lee, Yong-Hee;Yun, Jong-Hun;Lee, Yong-Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.21-29
    • /
    • 2012
  • Person characteristics and the perception of organization climate affect on the performances associated with causes of job stress, and may induce various types of human errors. For incidence, a person's adaptation to organizational traits can influence on a person's performance with tasks assigned as well as job satisfaction, a change of occupation, etc. There are several evaluation methods such as an aptitude test to evaluate the suitability of department allocation. However, only person's traits such as an aptitude has been associated with department allocation and job assignment for the personnel management. This paper shows not only an evaluation result on the job-stress of the workers in nuclear power plants (NPPs), but also the relationships between the job-stress and the coincidences of group-personal, team-personal traits. Then, we systematically deduct a basic information on the factors to be considered to manage the organizational traits and job stress. We expect this result can contribute to enhance the organizational management against to the human errors as well as for the promotion of safety and efficiency of NPPs.

A study on the selection of optimal marine engine and its techno- economical evaluation method (최적박용기관의 선정 및 그의 경제성 평가방법에 관한 연구)

  • 전효중;조기열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.51-66
    • /
    • 1984
  • The cost percentage of engine part in the total building cost of a ship is about 30-40% and the main engine occupies about 50% of the engine part cost. For certain ships the fuel bill can be as high as about 60-70% of the total operating cost after two oil shocks and its amount for one year is nearly equivalent to her main engine price. This fact has further increased the pressure on the engine builders to develop engines of higher efficiency and better possibilities to burn further deteriorated fuel qualities. But the energy-saving plants are ordinarily more expensive and their available amount of exhaust gas energy is less and therefore, they are not always profitable and optimum systems. This paper is prepared to decide the most economical and efficient engine systems by presenting reasonable selecting and economical evaluation methods of the main engine, which is the largest single unit and the most expensive, and its auxiliaries. In order to demonstrate the application of investigated methods in a practical case, a 46, 000 DWT class bulk carrier is selected as a model ship and her main engine and its auxiliaries are selected and evaluated. The result shows that the optimum determined has one year three months POP, 0.903 IRR at a year, 4, 116, 000 dollars PW in 15 years (for 5% escalation rate of fuel cost) and 9.522 BCR for same condition, when the engine plant of a same existing ship is taken as the basis.

  • PDF

The influence of air gaps on buffer temperature within an engineered barrier system

  • Seok Yoon;Gi-Jun Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4120-4124
    • /
    • 2023
  • High-level radioactive waste produced by nuclear power plants are disposed subterraneously utilizing an engineered barrier system (EBS). A gap inevitably exists between the disposal canisters and buffer materials, which may have a negative effect on the thermal transfer and water-blocking efficiency of the system. As few previous experimental works have quantified this effect, this study aimed to create an experimental model for investigating differences in the temperature changes of bentonite buffer in the presence and absence of air gaps between it and a surrounding stainless steel cell. Three test scenarios comprised an empty cell and cells partially or completely filled with bentonite. The temperature was measured inside the buffers and on the inner surface of their surrounding cells, which were artificially heated. The time required for the entire system to reach 100℃ was approximately 40% faster with no gap between the inner cell surface and the bentonite. This suggests that rock-buffer spaces should be filled in practice to ensure the rapid dissipation of heat from the buffer materials to their surroundings. However, it can be advantageous to retain buffer-canister gaps to lower the peak buffer temperature.

An Analysis on Current Status of Certification for Green Building Revitalization in School - Focused on the School Located in Gyeonggi-do Province - (학교시설의 녹색건축 활성화를 위한 인증현황 분석 연구 - 경기도 학교시설을 중심으로 -)

  • Kim, Jang-Young;Kim, Sung-Joong;Lee, Seung-Min
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.14 no.3
    • /
    • pp.9-17
    • /
    • 2015
  • In this paper, there are several analysis on G-SEED, Building Energy Efficiency Rating System, Energy Performance Index, Energy Saving Plan about how they are applied by classification and planning standard. The analysis result found out that G-SEED has low select percentage by having difficulties to managing and additional cost when the each class is selected. And also, Building Energy Efficiency Rating System in school is planed in comparably simple design and similar size and also mostly uses high efficient machines, which was in high lever comparing to the system in facilities in other uses. In the case of EPI, there are differences on acquiring grades by each region. Especially, Gyung-gi region has a low grade on architecture part comparing to other parts, which seems to acquire more grades by strengthen insulation performance. By the result from the three standards, many facilities has only formal plan to pass the required standard without considering specialities of each buildings, which has a tendency to have a pattern to have a minimum criteria. However, School has a symbolic building which has a obligation to be the base of the aim for growing green energy buildings and green education for students. Therefore, planning with understanding of specialities of the facility, having various and rational evaluation standards from the planning of the building is necessary.

Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop (파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Lee, Kang-Ja;Choi, Hang-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Study for Support Structure of Liftable Car Deck on PCTC (자동차 운반선 이동식 갑판의 Latch 보강 적정설계 연구)

  • Na, Yongmoon;Chae, Wooki
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.60-65
    • /
    • 2013
  • Now days, the demands of new type hull lines and optimum design in relation with the EEDI (Energy Efficiency Design Index) regulation and eco-friendly high efficiency vessel design are mandatory clauses in Euro financial crises era. Therefore, in correlation with the above, we tried to find the optimum results and revealed the alterations of supporting structure for liftable car deck latch on PCTC. Generally, PCTC (Pure Car & Truck Carrier) design has been performed by 2 pillar space model F. E analysis without vehicle loads on liftable car deck to evaluate the structural adaptability. So, we applied mentioned vehicle loads on pillar and side transverse web on model to compare with not applied model and performed the ultimate strength analysis of improved design for the safety evaluation.

  • PDF

A study on advanced EMU's maintenance program on test operation in Dabul line (차세대 전동차 대불선 시운전 시 유지보수방안 연구)

  • Kim, Young-Kyu;Park, Se-Young;Song, Jeong-Hun;An, Cheon-Heon;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2215-2222
    • /
    • 2010
  • Advanced EMU have been enhanced in terms of safe transport and maintainability. It is a new urban railway technology that enables an operation institution to cut repair and maintenance costs and customers to use convenient service at lower costs based on IT technology. If a development vehicle of Advanced EMU is completed, it will be used to test the entire advanced EMU system through sufficient performance check and reliability check prior to operation in commercial line. It will also verify efficiency, safety, punctuality and energy efficiency of transport. Accordingly, it is necessary to figure how to repair and maintain vehicles to enhance safety of Advanced EMU system in cooperation with operation during the period of comprehensive evaluation on the operation of a development vehicle in a test line. In this paper, we investigated the maintenance program of Advanced EMU on test operation in Dabul line. The test condition and operation environment of Advanced EMU in Daebul line was analyzed.

  • PDF

Study on Evaluation Analysis on Thermal Performance of Window Using A. S. Lab.(Artificial Solar Laboratory) (인공태양실험실(A. S. Lab.)을 활용한 창호의 열성능 평가에 관한 연구)

  • Kang, Ki-Nam;Lee, Keon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.812-819
    • /
    • 2010
  • Recently residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. Along this the increased size and transparency of window as well as light surface caused by high stories lowers the heat shield efficiency of building. Since glass that constitutes building surface has low heat efficiency, it aggravates heat loss of all building considerably, thereby resulting in extreme heating load and cooling load in the country where temperature varies much in summer and winter. The research will check whether experiment can be effectively done by overcoming the limit of existing artificial solar laboratory constructed in the country and properly adjusting controlled variables with simplified function through construction of this experimental set.