• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 867, Processing Time 0.029 seconds

The Development and Performance Evaluation of a Cyclone to Remove Hot Particulate from a Contaminated Hot Cell (Hot Cell 내에 오염된 고방사능분진 제거를 위한 사이클론 개발 및 성능평가)

  • Kim Gye-Nam;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.217-226
    • /
    • 2006
  • The structural and contamination characteristics of hot cells at KAERI were investigated. The SEM results showed that the size of the hot particulate on the inner surface of the hot cell ranged from 0.2 to $10{\mu}m$. It was found that an inlet flow rate of 15 m/sec was suitable for this developed cyclone with a 49 mm optimum vortex finder length. The results showed that the collection efficiency was about 85% for $3{\mu}m$ particles. The collection efficiency didn't show a sharp increase when the inlet flow rate was faster than 15m/sec. When the temperature of the inlet flow gas was increased, the collection efficiency of the cyclone was slightly decreased. The larger the vortex finder length was, the higher the pressure drop in the cyclone was. The cut size diameter decreased with an increment of the Reynolds number. It was established that the flow in the cyclone was a turbulent flow on the basis of the Reynolds number and this turbulent flow caused a pressure drop in the cyclone. $Stk^{1/2}_{50}$ decreased with increasing values of the Reynolds number and it gradually approached a constant value at a higher value of the Reynolds number Namely, $Stk^{1/2}_{50}$ approached approximately 0.045 between 6000 and 8000 of the Reynolds number.

  • PDF

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile (병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가)

  • Park, Sangwoo;Kim, Byeongyeon;Sung, Chihun;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.361-375
    • /
    • 2015
  • An energy pile is one of the novel ground heat exchangers (GHEX's) that is a economical alternative to the conventional closed-loop vertical GHEX. The combined system of both a structural foundation and a GHEX contains a heat exchange pipe inside the pile foundation and allows a working fluid circulating through the pipe, inducing heat exchange with the ground formation. In this paper, a group of energy piles equipped with parallel U-type (5, 8 and 10 pairs) heat exchange pipes was constructed in a test-bed by fabricating in large-diameter cast-in-place concrete piles. In addition, a closed-loop vertical GHEX with 30m depth was constructed nearby to conduct in-situ thermal response tests (TRTs) and to compare with the thermal performance of the cast-in-place energy piles. A series of thermal performance tests was carried out with application of an artificial cooling and heating load to evaluate the heat exchange rate of energy piles. The applicability of cast-in-place energy piles was evaluated by comparing the relative heat exchange efficiency and heat exchange rate with preceding studies. Finally, it is concluded that the cast-in-place energy piles constructed in the test-bed demonstrate effective and stable thermal performance compared with the other types of GHEX.

Effect of energy density and virginiamycin supplementation in diets on growth performance and digestive function of finishing steers

  • Navarrete, Juan D.;Montano, Martin F.;Raymundo, Constantino;Salinas-Chavira, Jaime;Torrentera, Noemi;Zinn, Richard A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1396-1404
    • /
    • 2017
  • Objective: This study was determined the influence of virginiamycin supplementation on growth-performance and characteristics of digestion of cattle with decreasing dietary net energy value of the diet for maintenance ($NE_m$) from 2.22 to 2.10 Mcal/kg. Methods: Eighty crossbred beef steers ($298.2{\pm}6.3kg$) were used in a 152-d performance evaluation consisting of a 28-d adaptation period followed by a 124-d growing-finishing period. During the 124-d period steers were fed either a lesser energy dense (LED, $2.10Mcal/kg\;NE_m$) or higher energy dense (HED, $2.22Mcal/kg\;NE_m$) diet. Diets were fed with or without 28 mg/kg (dry matter [DM] basis) virginiamycin in a $2{\times}2$ factorial arrangement. Four Holstein steers ($170.4{\pm}5.6kg$) with cannulas in the rumen (3.8 cm internal diameter) and proximal duodenum were used in $4{\times}4$ Latin square experiment to study treatment effects on characteristics of digestion. Results: Neither diet energy density nor virginiamycin affected average daily gain (p>0.10). As expected, dry matter intake and gain efficiency were greater (p<0.01) for LED- than for HED-fed steers. Virginiamycin did not affect estimated net energy value of the LED diet. Virginiamycin increased estimated NE of the HED diet. During daylight hours when the temperature humidity index averaged $81.3{\pm}2.7$, virginiamycin decreased (p<0.05) ruminal temperature. Virginiamycin did not influence (p>0.10) ruminal or total tract digestion. Ruminal (p = 0.02) and total tract digestion (p<0.01) of organic matter, and digestible energy (p<0.01) were greater for HED vs LED. Ruminal microbial efficiency was lower (p<0.01) for HED vs LED diets. Conclusion: The positive effect of virginiamycin on growth performance of cattle is due to increased efficiency of energy utilization, as effects of virginiamycin on characteristics of digestion were not appreciable. Under conditions of high ambient temperature virginiamycin may reduce body temperature.

A Basic Study for Sustainable Analysis and Evaluation of Energy Environment in Buildings : Focusing on Energy Environment Historical Data of Residential Buildings (빌딩의 지속가능 에너지환경 분석 및 평가를 위한 기초 연구 : 주거용 건물의 에너지환경 실적정보를 중심으로)

  • Lee, Goon-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.262-268
    • /
    • 2017
  • The energy consumption of buildings is approximately 20.5% of the total energy consumption, and the interest in energy efficiency and low consumption of the building is increasing. Several studies have performed energy analysis and evaluation. Energy analysis and evaluation are effective when applied in the initial design phase. In the initial design phase, however, the energy performance is evaluated using general level information, such as glazing area and surface area. Therefore, the evaluation results of the detailed design stage, which is based on the drawings, including detailed information of the materials and facilities, will be different. Thus far, most studies have reported the analysis and evaluation at the detailed design stage, where detailed information about the materials installed in the building becomes clear. Therefore, it is possible to improve the accuracy of the energy environment analysis if the energy environment information generated during the life cycle of the building can be established and accurate information can be provided in the analysis at the initial design stage using a probability / statistical method. On the other hand, historical data on energy use has not been established in Korea. Therefore, this study performed energy environment analysis to construct the energy environment historical data. As a result of the research, information classification system, information model, and service model for acquiring and providing energy environment information that can be used for building lifecycle information of buildings are presented and used as the basic data. The results can be utilized in the historical data management system so that the reliability of analysis can be improved by supplementing the input information at the initial design stage. If the historical data is stacked, it can be used as learning data in methods, such as probability / statistics or artificial intelligence for energy environment analysis in the initial design stage.

A Study on Performance Evaluation for the Bio-retention Non-point Source Pollution Treatment System (생물 저류 방법 적용을 통한 비점오염원 처리시설의 성능평가에 관한 연구)

  • Lee, Jang-Soo;Park, Yeon-Soo;Cho, Wook-Sang
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.295-299
    • /
    • 2013
  • This study was purposed and performed to evaluate removal efficiency of non-point source pollution in the process and system based on bio-retention design criteria regulated by EPA. Basic Column Reactors (BCR) were prepared for optimal determinations of inflow rate of first rainfall runoff and composition and ratio of soil layers. Removal efficiencies of non-point source pollution from synthetic runoff and real first rainfall runoff, directly sampled from motor way and parking lot, were analyzed, respectively. Removal efficiency of SS, BOD, COD, T-N, and T-P were all shown to be more than 80%.

Evaluation on Characteristics and Economical Efficiency of X-L Pipe Boiler with Electric Heat Closed Type (전열밀폐식 X-L 파이프 보일러 난방장치의 특성 및 경제성 평가)

  • Kim, Su-Man;Chun, Tae-Kyu;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.330-337
    • /
    • 2011
  • In these days, the gas or kerosene boiler was usually used as heating system. This study was carried out to investigate the merits of X-L pipe boiler with electric heat line that was specially manufactured. The electric heat line was inserted into inside of X-L pipe and voltage was impressed to electric heat line and, as a result, temperature of X-L pipe filled with heat medium was increased. As changing the number of electric heat line and voltage, the characteristics of X-L pipe boiler and its mechanism on heat generation were studied. Furthermore, the economical efficiency was evaluated by comparing heating cost of X-L pipe boiler with those of kerosene boiler and natural gas boiler, respectively. As the results, it was confirmed that heating cost of X-L pipe boiler was showed as 28% of kerosene boiler and 58% of natural gas boiler.

Priority Analysis of Climate Smart Agriculture (CSA) Technology using Analytic Hierarchy Process (AHP) (계층화 분석기법(AHP)을 이용한 기후스마트농업(CSA) 기술의 우선순위 분석)

  • HyunJi Lee;KyungJae Lee;Sung Eun Sally Oh;Yun Yeong Choi;Brian H.S. Kim
    • Journal of Korean Society of Rural Planning
    • /
    • v.28 no.4
    • /
    • pp.127-138
    • /
    • 2022
  • In responding to climate change in the agricultural sector, Climate Smart Agriculture (CSA) is an approach to establish a sustainable agricultural system through comprehensive management of technology, policy, and investment. The international community is continually expanding CSA implementation, and it became more important to understand the status of the domestic agriculture system and practices that are relevant to CSA. This study explored the available CSA in domestic agricultural systems and presented the order of relative importance of CSA technology. AHP analysis is employed for the evaluation with the following criteria: productivity, marketability, adaptability, and mitigation. The relative importance is evaluated with six agricultural technologies (soil, crop management, water, energy efficiency, alternative energy, and precision agriculture) in 28 agricultural technology sectors. The results of the AHP analysis showed that 'alternative energy' was found to be a top priority among the agricultural technology sectors, and 'shallow depth drain in rice paddy' was a top priority for agricultural technology. Also, the 'marketability' in soil and water sectors, 'mitigation' in crop management, and 'adaptability' in energy efficiency and alternative energy were given higher priority. The results of this study can be used as a good source for strategic CSA preparation and application.

Integrated Evaluation of Advanced Activated Sludge Processes Based on Mathematical Model and Fuzzy Inference (수학적 모델 및 퍼지 추론에 의한 고도 활성슬러지 공정의 통합 평가)

  • Kang, Dong-Wan;Kim, Hyo-Su;Kim, Ye-Jin;Choi, Su-Jung;Cha, Jae-Hwan;Kim, Chan-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.97-104
    • /
    • 2010
  • At present, the biological nutrient removal (BNR) process for removal of nitrogen and phosphorus is being constructing to keep pace with the reinforced standard of effluent quality and the traditional activated sludge process of preexistence is being promoting to retrofit. At the most case of retrofitting, processes are subjected to be under consideration as alternative BNR process for retrofitting. However, process evaluation methods are restricted to compare only treatment efficiency. Therefore, when BNR process apply, process evaluation was needed various method for treatment efficiency as well as sludge production and aeration cost, and all. In this study, the evaluation method of alternative process was suggested for the case for retrofitting S wastewater treatment plant which has been operated the standard activated sludge process. Three BNR processes for evaluation of proper alternatative process were selected and evaluated with suggested method. The selected $A^2$/O, VIP and DNR processes were evaluated using the mathematical model which is time and cost effective as well as gathered objective evaluation criteria. The evaluation between 5 individual criteria was possible including sludge production and energy efficiency as well as treatment performance. The objective final decision method for selection of optimal process was established through the fuzzy inference.

Multi-MW Class Wind Turbine Blade Design Part II : Structural Integrity Evaluation (Multi-MW급 풍력발전용 블레이드 설계에 관한 연구 Part II : 구조 건전성 평가)

  • Kim, Bum Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.311-320
    • /
    • 2014
  • Rotor blades are important devices that affect the power performance, efficiency of energy conversion, and loading and dynamic stability of wind turbines. Therefore, considering the characteristics of a wind turbine system is important for achieving optimal blade design. When a design is complete, a design evaluation should be performed to verify the structural integrity of the proposed blade in accordance with international standards or guidelines. This paper presents a detailed exposition of the evaluation items and acceptance criteria required for the design certification of wind turbine blades. It also presents design evaluation results for a 2-MW blade (KR40.1b). Analyses of ultimate strength, buckling stability, and tip displacement were performed using FEM, and Miner's rule was applied to evaluate the fatigue life of the blade. The structural integrity of the KR40.1b blade was found to satisfy the design standards.