The Development and Performance Evaluation of a Cyclone to Remove Hot Particulate from a Contaminated Hot Cell

Hot Cell 내에 오염된 고방사능분진 제거를 위한 사이클론 개발 및 성능평가

  • Published : 2006.09.01

Abstract

The structural and contamination characteristics of hot cells at KAERI were investigated. The SEM results showed that the size of the hot particulate on the inner surface of the hot cell ranged from 0.2 to $10{\mu}m$. It was found that an inlet flow rate of 15 m/sec was suitable for this developed cyclone with a 49 mm optimum vortex finder length. The results showed that the collection efficiency was about 85% for $3{\mu}m$ particles. The collection efficiency didn't show a sharp increase when the inlet flow rate was faster than 15m/sec. When the temperature of the inlet flow gas was increased, the collection efficiency of the cyclone was slightly decreased. The larger the vortex finder length was, the higher the pressure drop in the cyclone was. The cut size diameter decreased with an increment of the Reynolds number. It was established that the flow in the cyclone was a turbulent flow on the basis of the Reynolds number and this turbulent flow caused a pressure drop in the cyclone. $Stk^{1/2}_{50}$ decreased with increasing values of the Reynolds number and it gradually approached a constant value at a higher value of the Reynolds number Namely, $Stk^{1/2}_{50}$ approached approximately 0.045 between 6000 and 8000 of the Reynolds number.

원자력연구소 핫셀의 구조와 오염특성이 조사되었다. SEM 측정결과 핫셀 내부에 부착된 고방사능 분진의 크기는 $0.2{\sim}10{\mu}m$이었다. 사이클론의 최적 Vortex finder의 길이는 49 mm이고, 모의입자 유입속도는 15m/sec가 적합했다. 이때 $3{\mu}m$의 포집효율은 약 85%였다. 모의 입자 유입속도가 15m/sec보다 빠를 때, 포집효율의 증가율은 크지 않았다. 유입가스의 온도가 증가할 때, 포집효율은 약간 감소했다. Vortex finder의 길이가 증가할수록 사이클론내의 압력강하는 커졌다. Cut size diameter는 Reynolds number의 증가와 함께 감소했다. 측정된 Reynolds number에 근거하면, 사이클론 내부는 난류이고 이 난류는 사이클론 내의 압력강하에 원인이 된다고 사료된다. $Stk^{1/2}_{50}$는 Re 값의 증가와 함께 감소하고, Re의 값이 커질 때에서 일정한 값에 수렴했다. 즉, 6000-8000의 Re에서 $Stk^{1/2}_{50}$는 약 0.045를 나타냈다.

Keywords