• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 867, Processing Time 0.029 seconds

Mutual Accreditation of Certification Systems for Apartment Housing - Focused on Green Building Certification Criteria and Good Housing Certification System - (공동주택 관련 인증제도 간 상호 인정 방안 - 친환경건축물인증제도와 주택성능등급표시제도를 중심으로 -)

  • Ahn, Sun Ju;Song, Sang Hoon
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.35-44
    • /
    • 2011
  • Many countries have run their own certification systems in order to reduce the environmental loads from buildings. Domestically, various systems are applied according to building types from Building Energy Efficiency Rating System since 2001 to Green Home Construction Standard and Performance since 2009. However, these systems provide the applicants with confusion and waste by exposing them to several systems simultaneously, some of which are mandatory. Therefore, this study aims to ensure the flexibility among those systems and eliminate the possible waste by suggesting mutual accreditation method of evaluation results. To achieve this purpose, firstly, the thirteen similar evaluation items are identified between Housing Performance Grading Indication System and Green Building Rating System. Then, the mutual accreditation method is developed by comparing detailed evaluation criteria and credits for those thirteen items.

The Analysis CO2 Emission and Economic Efficiency of High-rise Apartment Houses (초고층 공동주택의 CO2 배출량과 경제성 분석에 관한 연구)

  • Roh, Seung-Jun;Tae, Sung-Ho;Kim, Tae-Hyoung;Keum, Won-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.47-48
    • /
    • 2012
  • In this study, the CO2 emission and economic efficiency of high-rise apartment houses were evaluated, and were analyzed as a way to establish database on the evaluation of environment-friendliness of high-rise buildings. To that end, standard of buildings to be evaluated were proposed through analysis of the designing guideline for high-rise apartment houses proposed by Seoul city, and CO2 emission of the subject buildings were evaluated based on the characteristics of materials admitted into each building and the amounts of energy consumed during lifecycle period. In addition, the initial costs in construction stage and annual costs in operation stage were set as analysis parameters, and along with calculation of direct cost by the consumption of construction materials and energy, the costs of CO2 emission were evaluated and analyzed. As a result, the CO2 emission and economic efficiencies of high-rise apartment houses by construction stage and operation stage could be analyzed quantitatively.

  • PDF

A Performance Evaluation of Plate Type Enthalpy Exchanger through CFD Analysis of Elements (열 교환 소자 형상의 CFD 시뮬레이션을 통한 판형 전열 교환기 성능평가)

  • Kang, In-Sung;Ahn, Tae-Kyung;Park, Jin-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In order to better save energy, many buildings have been constructed with high levels of insulation and airtightness in recent years. Additionally, having high quality indoor air has become more relevant, necessitating a ventilating system. This study is aimed at evaluating the performance of a humidity exchanger through computational fluid dynamics (CFD) analysis of elements for the purpose of providing comfortable indoor air and reduced energy consumption. The simulation was conducted with three different shapes (triangle, rectangular, and curve) of heat exchanger elements, in order to find the most effective element. A follow-up simulation then proved the efficiency of the chosen humidity exchanger, which was selected by analyzing the results of the preceding simulation, comparing study data with measurement data from the Korea Testing Laboratory (KTL). The resulting analysis revealed that the rectangular element showed the lowest level of efficiency in both heating and cooling, while the curved element showed the highest level of efficiency in both heating and cooling.

Tracepro Simulation Design and Evaluation for the Double Blind Light Pipe Daylighting System (Tracepro를 활용한 이중 블라인드 광파이프 채광 시스템의 블라인드 설계 및 시스템 효율 평가)

  • Kang, Eun-Chul;Lee, Euy-Joon;Yo, Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.515-520
    • /
    • 2012
  • A daylighting system includes three parts; light collector, light transformer and light distributor. A DBLP(Double blind light pipe) daylighting system consists of a double blind light collector, a mirror duct type light transformer and a prism film light pipe distributor. The double blinds for a light collection are used to track the sun's altitude and azimuth movements throughout the day. Behind both sets of blinds is the light transformer, which is based on a rectangular cone shaped light duct. The light transformer was designed to efficiently deliver the light into the light pipe within a 30 degree radial spread for the efficient light into the distributor. In this study, DBLP system efficiency was simulated, evaluated and optimized by Tracepro as a popular ray trace light design simulation program. The results indicated that DBLP system efficiency evaluated a maximum 22.4% in case of Spring/Fall season solar noon time. While the overall average system efficiency in the morning and afternoon is evaluated about 10%.

Evaluation on MUSLE Runoff Energy Coefficient in Small Forest Watershed (산림소유역에서 MUSLE 유출에너지인자 계수값의 적용성 평가)

  • Kim, Jaehoon;Choi, Hyung Tae;Lim, Hong-geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.191-200
    • /
    • 2015
  • This study was carried out to investigate coefficient and exponent of runoff energy in MUSLE for small forest watershed, Hwachoen watershed in Gangwon-do. For 15 rainfall events, runoff volume, peak discharge and sediment yield were measured and these data were used to calculate coefficient and exponent of runoff energy. The results of this study showed that $LS{\bullet}K{\bullet}C{\bullet}P$ factors of MUSLE were affected by slope steepness. The coefficient and exponent of runoff energy were validated with coefficient of efficiency of 0.92 and these values were suggested to 0.002 and 0.81 respectively. The comparison of the coefficients and exponents between Hwacheon and other forest watersheds showed that these values would reflect the effect of forest management within watershed.

A Study of Fabrication Techniques of Thin film Photo-Electric Energy Conversion Elements (박막 광전에너지 변환소자의 개발에 관한 연구)

  • 성영권;민남기;성만영;김승배
    • 전기의세계
    • /
    • v.25 no.5
    • /
    • pp.63-69
    • /
    • 1976
  • Among various types of photo-electric energy conversion element which can transfer solar energy into electric energy through the photo voltaic effect, Si solar cells were investigated on photoelectric characteristics, improvements of its efficiency and economical evaluation for its production cost. To study the above subjects, we decided best conditions on fabricating of thin film Si solar cell by epitaxial growth and knew that the thin solar cell by epitaxial growth was more efficient than that by diffusion process. And also higher photo voltaic output was obtained as a effect of SiO as antireflection coating by several methods, i.e. vacuum evaporating techniques of electrode to decrease the contact resistance and to form best ohmic contact, and concentration techniques of sun's ray by lenz or both-sided illumination through special structure for reflection using mirrors.

  • PDF

Development of monitoring program for performance evaluation in solar_heat hot-water -boiler (태양열온수기 성능평가를 위한 모니터링 프로그램개발)

  • 김재열;오율권;곽희열;한재호;송경석;양동조
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.260-264
    • /
    • 2003
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar-heat hot-water-boiler with high efficiency has been used for the house and the industrial process on business, advanced nations on reached up the experimental stage of solar generation system. But the actual circumstance of the domestic has been not accomplished the popularization of solar-heat hot-water-boiler and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar-heat hot-water-boiler, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar-heat hot-water-boiler, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid f3r the enlargement and the popularization on solar energy.

  • PDF

A Robust Transport Protocol Based on Intra-Cluster Node Density for Wireless Sensor Networks (무선 센서 네트워크를 위한 클러스터 내 노드 밀도 기반 트랜스포트 프로토콜)

  • Baek, Cheolheon;Moh, Sangman
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.6
    • /
    • pp.381-390
    • /
    • 2015
  • The efficient design of a transport protocol contributes to energy conservation as well as performance improvement in wireless sensor networks (WSNs). In this paper, a node-density-aware transport protocol (NDTP) for intra-cluster transmissions in WSNs for monitoring physical attributes is proposed, which takes node density into account to mitigate congestion in intra-cluster transmissions. In the proposed NDTP, the maximum active time and queue length of cluster heads are restricted to reduce energy consumption. This is mainly because cluster heads do more works and consume more energy than normal sensor nodes. According to the performance evaluation results, the proposed NDTP outperforms the conventional protocol remarkably in terms of network lifetime, congestion frequency, and packet error rate.

Insulation Performance Evaluation of the Curtain Wall Anchoring Unit by 3D Heat Transfer Simulation and Life Cycle Cost Analysis (3차원 전열해석 및 생애비용 분석을 통한 커튼월 앵커링 유닛의 단열성능 향상 방안 평가)

  • Kang, Seung-Hee;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.63-70
    • /
    • 2003
  • It is very important to improve the insulation performance of curtain wall anchoring unit since it is composed of materials with high thermal conductivity, such as aluminium, steel and so on. This study aims to evaluate the heating energy performance and economical efficiency of various alternatives which are different in position and material of insulation. As results, alternative of inserting the urethane washer & pad and coating the anchoring unit with urethane foam can improve the heating energy performance and L.C.C(Life Cycle Cost) by 6.33% and 0.95%, respectively, as compared with the existing case.

Analysis and Evaluation of 3kW Grid-Connected PV System by Field Demonstration Test (3kW급 계통연계형 태양광발전시스템의 실증시험 분석평가)

  • So, Jeong-Hoon;Yu, Gwon-Jong;Jung, Myung-Woong;Jung, Young-Seok;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1353-1355
    • /
    • 2003
  • Total six units of 3kW photovoltaic (PV) system and data acquisition system (DAS) are constructed for analyzing performance of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data-acquisition system. Furthermore, not only performance test of each PV system component such as PV module and power conditioning system, but also performance of total PV system e.g. system efficiency, electric power and loss factor at the site are reviewed.

  • PDF