• Title/Summary/Keyword: Energy converts

Search Result 240, Processing Time 0.03 seconds

CNN Based Spectrum Sensing Technique for Cognitive Radio Communications (인지 무선 통신을 위한 합성곱 신경망 기반 스펙트럼 센싱 기법)

  • Jung, Tae-Yun;Lee, Eui-Soo;Kim, Do-Kyoung;Oh, Ji-Myung;Noh, Woo-Young;Jeong, Eui-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.276-284
    • /
    • 2020
  • This paper proposes a new convolutional neural network (CNN) based spectrum sensing technique for cognitive radio communications. The proposed technique determines the existence of the primary user (PU) by using energy detection without any prior knowledge of the PU's signal. In the proposed method, the received signal is high-rate sampled to sense the entire spectrum bands of interest. After that, fast Fourier transform (FFT) of the signal converts the time domain signal to frequency domain spectrum and by stacking those consecutive spectrums, a 2 dimensional signal is made. The 2 dimensional signal is cut by the sensing channel bandwidth and inputted to the CNN. The CNN determines the existence of the primary user. Since there are only two states (existence or non-existence), binary classification CNN is used. The performance of the proposed method is examined through computer simulation and indoor experiment. According to the results, the proposed method outperforms the conventional threshold-based method by over 2 dB.

Effect of Steam-Treated Zeolite BEA Catalyst in NH3-SCR Reaction (NH3-SCR 반응에서 스팀 처리된 zeolite BEA 촉매의 영향)

  • Park, Ji Hye;Cho, Gwang Hee;Hwang, Ra Hyun;Baek, Jeong Hun;Yi, Kwang Bok
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Nitrous oxide (N2O) is one of the six greenhouse gases, and it is essential to reduce N2O by showing a global warming potential (GWP) equivalent to 310 times that of carbon dioxide (CO2). Selective catalytic reduction (SCR) is a technology that converts ammonia into harmless N2 and H2O by using ammonia as a reducing agent to remove NOx, one of the air pollutants; the process also produces high denitrification efficiency. In this study, the Fe-BEA catalyst was steam-treated at 100 ℃ for 2 h before Fe ion exchange in the fixed bed reactor in order to investigate the effect of the steam-treated Fe-BEA catalyst on the NH3-SCR reaction. NH3-SCR reaction test of synthesized catalysts was performed at WHSV = 180 h-1, 370 to 400 ℃ in the fixed bed reactor. The Fe-BEA(100) catalyst steam-treated at 100 ℃ showed a somewhat higher activity than the Fe-BEA catalyst at 370 to 390 ℃. The catalysts were characterized by BET, ICP, NH3-TPD, H2-TPR, and 27Al MAS NMR in order to determine the cause affecting NH3-SCR activity. The H2-TPR result confirmed that the Fe-BEA(100) catalyst had a higher reduction of isolated Fe3+ than the Fe-BEA catalyst, and that the steam treatment increased the amount of isolated Fe3+ as an active species, thus increasing the activity.

Effect of Major Factors on the Spray Characteristics of Ultrasonic Atomizing Nozzle (초음파 미립화 노즐의 분무 특성에 미치는 주요 인자의 영향)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • The atomization of a liquid into multiple droplets has many important industrial applications, including the atomization of fuels in combustion processes and coating of surfaces and particles. Ultrasonic atomizing nozzle has a transducer that receives electrical input in the form of a high frequency signal from a power generator and converts that into mechanical energy at the same frequency. Liquid is atomized into a fine mist spray using high frequency sound vibrations. In coating applications, the unpressurized, low-velocity spray reduces the amount of overspray significantly because the droplets tend to settle on the substrate, rather than bouncing off it. The spray can be controlled and shaped precisely by entraining the slow-moving spray in an ancillary air stream using specialized types of spray-shaping equipment. The desired patterns of spray can be obtained using an air stream. To simulate the water mist behavior of an ultrasonic atomizing nozzle using an air stream, the Lagrangian dispersed phase model was employed using the commercial code FLUENT. The effects of the nozzle contraction shape, water droplet size and the pneumatic pressure drop on the spray characteristics were investigated to obtain the optimal condition for coating applications.

A 3-D Measuring System of Thermoluminescence Spectra and Thermoluminescence of CaSO4 : Dy, P (열자극발광 스펙트럼의 3차원 측정 장치와 CaSO4 : Dy, P의 열자극발광)

  • Lee, Jung-Il;Moon, Jung-Hak;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2001
  • In this paper, a three-dimensional measuring system of thermoluminescence(TL) spectra based on temperature, wavelength and luminescence intensity was introduced. The system was composed of a spectrometer, temperature control unit for thermal stimulation, photon detector and personal computer for control the entire system. Temperature control was achieved by using feedback to ensure a linear-rise in the sample temperature. Digital multimeter(KEITHLEY 195A) measures the electromotive force of Copper-Constantan thermocouple and then transmits the data to the computer through GPIB card. The computer converts this signal to temperature using electromotive force-temperature table in program, and then control the power supply through the D/A converter. The spectrometer(SPEX 1681) is controlled by CD-2A, which is controlled by the computer through RS-232 communication port. For measuring the luminescence intensity during the heating run, the electrometer(KEITHLEY 617) measures the anode current of photomultiplier tube(HAMAMATSU R928) and transmits the data to computer through the A/D converter. And, we measured and analyzed thermoluminescence of $CaSO_4$ : Dy, P using the system. The measuring range of thermoluminescence spectra was 300K-575K and 300~800 nm, $CaSO_4$ : Dy. P was fabricated by the Yamashita's method in Korea Atomic Energy Research Institute(KAERI) for radiation dosimeter. Thermoluminesce spectra of the $CaSO_4$ : Dy, P consist of two main peak at temperature of $205^{\circ}C$, wavelength 476 nm and 572 nm and with minor ones at 658 nm and 749 nm.

  • PDF

A Study on the Evaluation of 3D Dose Distribution using Normoxic Polymer Gel (정상산소 중합체 겔 선량계를 이용한 3차원 방사선량 평가에 관한 연구)

  • Chung, Se-Young;Kim, Young-Bum;Kwon, Young-Ho;Lee, Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2007
  • Purpose: As increasing complexity of modern radiotherapy technique, more developing dosimetry is required. Polymer gel dosimeters offer a wide range of potential applications with high resolution and assured quality in the thee-dimensional verification of complex dose distribution such as intensity-modulated radiotherapy (IMRT). The purpose of this study is to find the most sensitive and suitable gel as a dosimeter by varying its composition ratio and its condition such as temperature during manufacturing. Materials and Methods: Each polymer gel with various ratio of composition was irradiated with the same amount of photon beam accordingly. Various polymer gels were analyzed and compared using a dedicated software written in visual C++ which converts TE images to R2 map images. Their sensitivities to the photon beam depending on their composition ratio were investigated. Results: There is no dependence on beam energy nor dose rate, and calibration curve is linear. Conclusion: The polymer gel dosimeter developed by using anti-oxidant in this study proved to be suitable for dosimetry.

  • PDF

An Algorithm for Managing Storage Space to Maximize the CPU Availability in VOD Systems (VOD 시스템에서 CPU 가용성을 최대화하는 저장공간관리 알고리즘)

  • Jung, Ji-Chan;Go, Jae-Doo;Song, Min-Seok;Sim, Jeong-Seop
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.3
    • /
    • pp.140-148
    • /
    • 2009
  • Recent advances in communication and multimedia technologies make it possible to provide video-on-demand(VOD) services and people can access video servers over the Internet at any time using their electronic devices, such as PDA, mobile phone and digital TV. Each device has different processing capabilities, energy budgets, display sizes and network connectivities. To support such diverse devices, multiple versions of videos are needed to meet users' requests. In general cases, VOD servers cannot store all the versions of videos due to the storage limitation. When a device requests a stored version, the server can send the appropriate version immediately, but when the requested version is not stored, the server first converts some stored version to the requested version, and then sends it to the client. We call this conversion process transcoding. If transcoding occurs frequently in a VOD server, the CPU resource of the server becomes insufficient to response to clients. Thus, to admit as many requests as possible, we need to maximize the CPU availability. In this paper, we propose a new algorithm to select versions from those stored on disk using a branch and bound technique to maximize the CPU availability. We also explore the impact of these storage management policies on streaming to heterogeneous users.

A Secure Multipath Transmission Scheme Based on One-Way Hash Functions in Wireless Sensor Networks (무선 센서 네트워크 환경에서 단-방향 해쉬 함수 기반 다중 경로 보안 전송 기법)

  • Lee, Yun-Jeong;Kim, Dong-Joo;Park, Jun-Ho;Seong, Dong-Ook;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.1
    • /
    • pp.48-58
    • /
    • 2012
  • With the development of sensing devices and wireless communication technologies, wireless sensor networks are composed of a large number of sensor nodes that are equipped with limited computing performance and restricted communication capabilities. Besides, the sensor nodes are deployed in hostile or unattended environments. Therefore, the wireless sensor networks are vulnerable to security. In particular, the fatal damage may be occurred when data are exposed in real world applications. Therefore, it is important for design requirements to be made so that wireless sensor networks provide the strong security. However, because the conventional security schemes in wired networks did not consider the limited performance of the sensor node, they are so hard to be applied to wireless sensor networks. In this paper, we propose a secure multipath transmission scheme based on one-way hash functions in wireless sensor networks considering the limited performance of the wireless sensor nodes. The proposed scheme converts a sensor reading based on one of one-way hash functions MD5 in order to make it harder to be cracked and snooped. And then, our scheme splits the converted data and transfers the split data to the base station using multi-path routing. The experimental results show that our proposed scheme consumes the energy of just about 6% over the existing security scheme.

Potential of Coal Gasification Slag as an Alkali-activated Cement (석탄가스화 복합발전 슬래그의 알칼리 활성 시멘트로서의 가능성)

  • Kim, Byoungkwan;Lee, Sujeong;Chon, Chul-Min;Choi, Hong-Shik
    • Resources Recycling
    • /
    • v.27 no.2
    • /
    • pp.38-47
    • /
    • 2018
  • Integrated gasification combined cycle (IGCC) is a next generation energy production technology that converts coal into syngas with enhanced power generation efficiency and environmental performance. IGCC produces almost coal gasification slag as the solid by-product. IGCC slag is generated about 140,000 tons for a year although recycling of it is still in the early stages. We evaluated the potential of IGCC slag which is generated from a pilot plant in South Korea as an alkali-activated cement. Samples which were activated with the combined activator of sodium silicate solution and caustic soda had an average compressive strength of 4.5 MPa, showing expansion. Expansion of the alkali-activated slag was presumed to be caused by free CaO in the slag, although it was not detected by the ethylene glycol method. Samples that were activated with the combined activator of sodium aluminate and caustic soda had an average compressive strength of 10 MPa. Hydroxy sodalite and $C_3AH_6$ were found to be the new crystalline phases. IGCC slag can be used as an alkali-activated material, but the strength performance should be improved with proper mix design approach to calculate optimum proportions which can alleviate the expansion issue at the same time.

A Study on the Design of a Beta Ray Sensor Reducing Digital Switching Noise (디지털 스위칭 노이즈를 감소시킨 베타선 센서 설계)

  • Kim, Young-Hee;Jin, Hong-Zhou;Cha, Jin-Sol;Hwang, Chang-Yoon;Lee, Dong-Hyeon;Salman, R.M.;Park, Kyung-Hwan;Kim, Jong-Bum;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.403-411
    • /
    • 2020
  • Since the analog circuit of the beta ray sensor circuit for the true random number generator and the power and ground line used in the comparator circuit are shared with each other, the power generated by the digital switching of the comparator circuit and the voltage drop at the ground line was the cause of the decreasein the output signal voltage drop at the analog circuit including CSA (Charge Sensitive Amplifier). Therefore, in this paper, the output signal voltage of the analog circuit including the CSAcircuit is reduced by separating the power and ground line used in the comparator circuit, which is the source of digital switching noise, from the power and ground line of the analog circuit. In addition, in the voltage-to-voltage converter circuit that converts VREF (=1.195V) voltage to VREF_VCOM and VREF_VTHR voltage, there was a problem that the VREF_VCOM and VREF_VTHR voltages decrease because the driving current flowing through each current mirror varies due to channel length modulation effect at a high voltage VDD of 5.5V when the drain voltage of the PMOS current mirror is different when driving the IREF through the PMOS current mirror. Therefore, in this paper, since the PMOS diode is added to the PMOS current mirror of the voltage-to-voltage converter circuit, the voltages of VREF_VCOM and VREF_VTHR do not go down at a high voltage of 5.5V.

The Electron Trap Analysis in Thermoluminescent LiF Crystal

  • Park, Dae-Yoon;Ko, Chung-Duck;Lee, Sang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.214-222
    • /
    • 1972
  • In the optic,11 grade LiF crystal, the electron traps corresponding to the thermoluminescence(abbreviated to TL) glow peak develop as irradiation dose is increased. Originally the electron trap of the crystal has two levels but as the dose reaches to the order of 10$^4$rontgen, it attains five levels as observed in the TL glow curves. The five trap depths are determined from the glow peak temperatures for two different heating rates, $\theta$=6.6$^{\circ}C$/sec and 3.4$^{\circ}C$/sec. The electron trap depths have the following values E$_1$=0.79 eV, E$_2$=0.93 eV, E$_3$=1.02 eV, E$_4$=1.35 eV, E$_{5}$=1.69eV. The special feature of thermoluminescence of optical grade LiF is that the traps, except E$_1$and E$_2$corresponding to 12$0^{\circ}C$ glow peak and 15$0^{\circ}C$ glow peak for $\theta$=6.6$^{\circ}C$/sec, have severe thermal instability, namely E$_3$, E$_4$and E$_{5}$ levels disappear during bleaching process. These defects in the optical grade LiF crystal seem annealed out during the course of TL measurement. The fresh or long time unused LiF(Mg) crystal shows only two glow peaks at 17$0^{\circ}C$ and 23$0^{\circ}C$ for $\theta$=6.6$^{\circ}C$/sec, but upon sensitization with r-ray irradiation, it converts to the six glow peak state. The four electron traps, E$_1$, E$_2$, E$_3$, and E$_{6}$ created by r-ray irradiation and corresponding to the glow peaks at T=10$0^{\circ}C$ 13$0^{\circ}C$, 15$0^{\circ}C$ and 29$0^{\circ}C$ are stable and not easily annealed out thermally, The sensitization essentially required to LiF(Mg) dosimeter is to give the crystal the stable six levels in the electron trap. In optical grade LiF, the plot between logarithm of total TL output versus logarithm of r-ray dose gives more supra-linear feature than that of LiF(Mg). However, if one takes the height of 12$0^{\circ}C$ glow peak(S=6.6$^{\circ}C$/sec), instead of the total TL output, the curve becomes close to that of LiF(Mg).

  • PDF