• Title/Summary/Keyword: Energy Ratio Factor

Search Result 550, Processing Time 0.028 seconds

Design of Friction Dampers for Seismic Response Control of a SDOF Building (단자유도 건물의 지진응답제어를 위한 마찰감쇠기 설계)

  • Min, Kyung-Won;Seong, Ji-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.22-28
    • /
    • 2010
  • Approximate analysis for a building installed with a friction damper is performed to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor(DMF). It is found out that DMF is dependent on friction force ratio and resonance frequency. Approximation of DMF and equivalent damping ratio of a friction damper is proposed with such assumption that the building with a friction damper shows harmonic steady-state response and narrow banded response behavior near resonance frequency. Linear transfer function from input external force to output building displacement is suggested from the simplified DMF equation. Root mean square of a building displacement is derived under earthquake-like random excitation. Finally, design procedure of a friction damper is proposed by finding friction force corresponding to target control ratio. Numerical analysis is carried out to verify the proposed design procedure.

Detailed Analysis on Operation Characteristics and Cooling Energy Saving Effect of Chiller Staging in an Office Building (사무소 건물에서 냉동기의 대수제어를 통한 냉동기 거동 특성 및 에너지 절감 효과 분석)

  • Seo, Byeong-Mo;Son, Jeong-Eun;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.4
    • /
    • pp.137-144
    • /
    • 2016
  • Commercial buildings account for a significant proportion of the total building energy use in Korea, and cooling energy, in turn, accounts for the largest proportion of total energy consumption in commercial buildings. Under this circumstance, chiller staging is considered to be a reasonable and practical solution for cooling energy saving. In this study, the part-load ratio and the operating characteristics of a vapor compression chiller were analysed within an office building. In addition, energy consumption among different chiller staging schemes was comparatively analysed. As a result, significant proportions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range from 0% through 50%, and thus energy consumption was significantly affected by the chiller COP at low part-load conditions, indicating that the chiller operation at the part-load is an important factor in commercial buildings. In addition, utilizing a sequential chiller staging scheme can reduce the annual cooling energy usage by more than 10.3% compared to operating a single chiller.

Dietary Assessment Using Dietary Pattern Analysis of Middle School Students in Seoul (서울 지역 일부 중학생의 식이 패턴에 따른 식생활 평가)

  • 유선영;송윤주;정효지;백희영
    • Journal of Nutrition and Health
    • /
    • v.37 no.5
    • /
    • pp.373-384
    • /
    • 2004
  • The objectives of this study were to identify dietary patterns of Korean middle school students and to investigate the characteristics of dietary intake of subjects with different dietary pattern. Three-day diet records were obtained from 163 male and 155 female 7th graders in Seoul, Korea. Food items from the diet records were aggregated into 22 food groups before subjected to factor analysis. Four dietary patterns emerged from factor analysis with different factor score. Cluster analysis using factor score classified subjects into three groups named 'Traditional' (n = 42), 'Westernized' (n = 135), and 'Intermediate' (n = 145). Major nutrient intake and dietary quality assessed by NAR (Nutrients Adequacy Ratio), MAR (Mean Adequacy Ratio), DDS (Dietary Diversity Score), and DVS (Dietary Variety Score) of the three groups were compared. Mean energy intakes of three groups were 1783, 1916, 1578 kcal in Traditional, Westernized, and Intermediate diet group respectively. Differences in nutrient intake of the groups were significant in all nutrients except vitamin B$_1$. Percent energy from fat was significantly higher in Westernized and Intermediate diet group, and cholesterol intake of Westernized diet group was higher than 300mg. NARs of most nutrients were higher in Traditional and Westernized than Intermediate diet group except vitamin E. Traditional and Westernized diet groups had the highest MAR of fourteen nutrients. DDS was the highest in Westernized and DVS was the highest in Traditional and Westernized diet group. Traditional diet groups had 22% of energy consumption from breakfast, significantly higher than other diet groups. In conclusion, these results suggest that Korean teenagers with Traditional diet pattern have lower diet in % energy from fat, diversity of food and regularity of meals. Future studies need to focus on the relationship between dietary patterns and health status of Korean teenagers.

Determination of Boron Isotopic Ratio by Using an Alpha Track Technique

  • Park, Yong-Joon;Pyo, Hyung-Yeal;Song, Kyu-Seok;Song, Byoung-Chul;Jee, Kwang-Yong;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1609-1612
    • /
    • 2006
  • The determination of the boron isotopic ratio in solutions was achieved by means of a solid state track detector by using an alpha track. The neutron flux was optimized by using a Cd-foil to find the optimum conditions for counting the number of alpha tracks on the selected solid detector caused by the (n, $\alpha$) nuclear reaction of boron. The home-made multi-dot detector plate was utilized in this study to increase the reproducibility of the measurement by uniformly drying the boron solution within the marked circle area on the detector plate. The experimental results of this study verified that the $^{11}B/^{10}B $ isotopic ratio can be measured by observing the number of alpha tracks for different concentrated standard solutions with various isotopic compositions. This technique was applied to the determination of $^{10}B$ enrichment factor in a biological sample for a boron neutron capture therapy.

A Comparative Study on Heating Energy Consumption for Apartment Based on the Annually Strengthened Criteria of Insulation (공동주택 연도별 단열기준 강화에 따른 에너지소요량 비교 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 2013
  • Energy consumption is closely related to our lives. As Korea has four seasons, heating and cooling system is considered as essential facilities for the residential buildings. Accordingly, the government has continuously strengthened the design criteria to improve energy for new and existing building to save energy. The most important factor in the energy efficiency analysis for apartment is the heat transmission coefficient, and the value is significantly different as the heating energy amount is greatly different according to the window area ratio versus facade area ratio. Therefore, it is time to conduct continuous set-up for goal to enhance efficiency and restriction on window area ratio versus facade area ratio.

High Temperature Viscosity Measurement of Coal Ash Slags in Oxidizing Atmosphere (산화성 분위기에서 석탁회분 슬래그의 고온 점도 측정)

  • 정봉진
    • Journal of Energy Engineering
    • /
    • v.4 no.3
    • /
    • pp.324-330
    • /
    • 1995
  • 석탄 연소로에 사용 적합한 석탄의 선정 및 조업조건의 설정에 도움을 주고, 석탁회분의 슬래깅 성향을 파악하기 위해서 갈탄부터 역청탄에 이르는 4종의 시료를 사용하여 산화성 분위기에서 고온 회전 점도계를 사용하여 석탄회분 슬래그의 점도를 온도의 함수로서 측정하였다. 또한 석탄회분의 슬래깅 성향을 해석하기 위해서, 석탄회분 조성을 사용한 Base/Acid Ratio, Lignite Factor 및 Silica Ratio 등의 주요한 인자들이 슬래그 점도에 미치는 영향을 고찰하였다.

  • PDF

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

Energy-based design base shear for RC frames considering global failure mechanism and reduced hysteretic behavior

  • Merter, Onur;Ucar, Taner
    • Structural Engineering and Mechanics
    • /
    • v.63 no.1
    • /
    • pp.23-35
    • /
    • 2017
  • A nonlinear static procedure considering work-energy principle and global failure mechanism to estimate base shears of reinforced concrete (RC) frame-type structures is presented. The relative energy equation comprising of elastic vibrational energy, plastic strain energy and seismic input energy is obtained. The input energy is modified with a factor depending on damping ratio and ductility, and the energy that contributes to damage is obtained. The plastic energy is decreased with a factor to consider the reduced hysteretic behavior of RC members. Given the pre-selected failure mechanism, the modified energy balance equality is written using various approximations for modification factors of input energy and plastic energy in scientific literature. External work done by the design lateral forces distributed to story levels in accordance with Turkish Seismic Design Code is calculated considering the target plastic drift. Equating the plastic energy obtained from energy balance to external work done by the equivalent inertia forces considering, a total of 16 energy-based base shears for each frame are derived considering different combinations of modification factors. Ductility related parameters of modification factors are determined from pushover analysis. Relative input energy of multi degree of freedom (MDOF) system is approximated by using the modal-energy-decomposition approach. Energy-based design base shears are compared with those obtained from nonlinear time history (NLTH) analysis using recorded accelerograms. It is found that some of the energy-based base shears are in reasonable agreement with the mean base shear obtained from NLTH analysis.

Energy and Inductance of a HTS Magnet with Various Aspect Ratios (마그넷 형상에 따른 고온초전도 마그넷의 에너지와 인덕턴스)

  • Kang, Myung-Hun;Kim, Young-Min;Ku, Dae-Kwan;Paik, Kyoung-Ho;Cha, Guee-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1134-1139
    • /
    • 2011
  • When the aspect ratio of a magnet varies, the magnetic field in the magnet also varies. The critical current of a tape-shaped HTS wire varies with the direction and magnitude of applied magnetic field. Consequently when the aspect ration of a HTS magnet varies, the critical current of a HTS magnet varies. This paper shows the relation between the aspect ratio of a magnet and the energy and inductance of a HTS magnet. The critical current is also shown at various aspect ratio of the magnet. The length of the HTS wire, inner diameter of the magnet, and number of pancake are chosen to be variables which varies the shape of the magnet. For a HTS magnet consisting of pancake windings, calculation results show the number of pancake windings are the prime factor which varied the energy and inductance of the magnet. The inner diameter of the magnet varies the energy and inductance of the magnet a little.

A Study on the Battery Storage Volume Optimization in case of DR Participation for the Minimization of the Customer's Investment Cost (BESS의 DR(Demand Response) 적용 시 수용가의 투자비 최소화를 위한 적정용량산출방법)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2013
  • The BESS(Battery Energy Storage System) is an useful device for load leveling, but the high cost, installation space and safety issues are the main barriers for supplying it widely. The important factor in supplying BESS to customers successfully is the payback period. As most of the H/W cost factors are uncontrollable, the optimization of storage volume can be useful factor in improving payback period. In order to obtain optimized BESS volume, the load factor, demand ratio, peak shaving ratio, electric rates and benefits from DR participation of customer should be analyzed. In this paper, we could verify the peak cutting capability and cost effectiveness under the some proposed conditions and changing value of PCS and battery based on the customers data after volume optimization process was applied, and we can identified the saturation point of load factor and shortening of customer's payback period.