The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee (Korea Research Institute of Ships & Ocean Engineering) ;
  • Lim, Chang Hwy (Korea Research Institute of Ships & Ocean Engineering) ;
  • Park, Jong-Won (Korea Research Institute of Ships & Ocean Engineering) ;
  • Kim, Ik-Hyun (Korea Research Institute of Ships & Ocean Engineering) ;
  • Moon, Myung Kook (Korea Atomic Energy Research Institute) ;
  • Lim, Yong-Kon (Korea Research Institute of Ships & Ocean Engineering)
  • Received : 2017.06.12
  • Accepted : 2017.10.24
  • Published : 2017.12.31

Abstract

Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

Keywords

References

  1. Jaffray DA, Battista JJ, Fenster A, Munro P. X-ray scatter in megavoltage transmission radiography: physical characteristics and influence on image quality. Med. Phys. 1994;21(1):45-60. https://doi.org/10.1118/1.597255
  2. Chan HP, Lam KL, Wu Y. Studies of performance of antiscatter grids in digital radiography: effect on signal-tonoise ratio. Med. Phys. 1990;17(4):655-664. https://doi.org/10.1118/1.596496
  3. Neitzel U. Grids or air gaps for scatter reduction in digital radiography: a model calculation. Med. Phys. 1992;19(2): 475-481. https://doi.org/10.1118/1.596836
  4. Boone JM, Seibert JA, Tang CM, Lane SM. Grid and slot scan scatter reduction in mammography: comparison by using Monte Carlo techniques. Radiology. 2002;222(2): 519-527. https://doi.org/10.1148/radiol.2222010491
  5. Barnes GT. Contrast and scatter in X-ray imaging. Radiographics. 1991;11(2):307-323. https://doi.org/10.1148/radiographics.11.2.2028065
  6. Tang CM, Stier E, Fischer K, Guckel H. Anti-scattering Xray grid. Microsyst. Technol. 1998;4:187-192. https://doi.org/10.1007/s005420050128
  7. Miller EA, Caggiano JA, Runkle RC, White TA, Bevill AM. Scatter in cargo radiography. Appl. Radiat. Isot. 2011;69: 594-603. https://doi.org/10.1016/j.apradiso.2010.12.006
  8. Aichinger H, Dierker J, Joite-Barfuss S, Sabel M. Radiation exposure and image quality in X-ray diagnostic radiology. 2nd Ed. Berlin Germany. Springer. 2012;53-64

Cited by

  1. 고에너지 X-선 영상검출을 위한 CdWO4 섬광체 두께와 반사체의 반사율 변화에 따른 광 수집량의 변화 vol.24, pp.12, 2017, https://doi.org/10.6109/jkiice.2020.24.12.1704
  2. 이온전리함 기반의 컨테이너 검색용 고에너지 X-선 선량 측정장치 개발 vol.24, pp.12, 2017, https://doi.org/10.6109/jkiice.2020.24.12.1711