• Title/Summary/Keyword: Enclosure System

Search Result 170, Processing Time 0.027 seconds

Inverse Radiation Analysis of a Two-Dimensional Irregular Geometry Using Unstructured Triangular Meshes (비정렬 삼각 격자를 이용한 2 차원 비직교 형상에서의 역복사 해석)

  • Yi, Kyung-Joo;Baek, Seung-Wook;Kim, Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.561-567
    • /
    • 2011
  • The inverse radiation analysis of a two-dimensional irregular configuration using unstructured triangular meshes is presented. In this study, an enclosure filled with an absorbing, emitting and scattering medium with diffusely emitting and reflecting opaque boundaries is considered. The finite volume method is applied to solve the radiative transfer equation in order to simulate the measured incident radiation values which are used as input data for the inverse analysis. The conjugate gradient method is adopted for the estimation of wall emissivities by minimizing the objective function at each iteration step. To verify the performance of the unstructured grid system, we compare the results with those using a structured grid system for the two-dimensional lopsided shape. The effect of measurement errors on the estimation accuracy is also investigated.

Optimal Transducer Positions of an Active Noise Control System with an Opening in an Enclosure (능동방음벽 시스템에서의 제어음원 위치에 관한 고찰)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.164-171
    • /
    • 2004
  • Active control techniques have been used in wide areas of noise and nitration control engineering and a noise barrier is one of them. Omoto's work in 1993 would be one of the fundamental and systematic studies on the actively controlled noise barrier, in which he used equal number of control sources and error sensors. The error sensors were placed uniformly along the top edge of the noise barrier with equal distance apart and the control sources were placed in the exactly same way some distance apart from the error sensors. Since then, a couple of studies were made on the secondary sources'arrangement rather than the optimality of secondary source positions. Shao's results showed that arc shaped arrangement for secondary sources is better than the straight line one, and later work of Yang showed that the more important factor is the average distance between the primary source and secondary sources. However, since these studies were all executed with a simple uniform distribution of the secondary sources along the straight line or arc, it is difficult to conclude which arrangement is superior In order for the fare comparison. the optimality of the source positions in each arrangement must be given in prior. The primary goal of this study is focused on this aspect and some major factors were investigated and compared. The computer simulation results showed that the arc shaped arrangement is marginally better than the straight line one, and more importantly slightly tuned position can greatly improve the performance of the control system.

A Study on the Spatial Allocation Planning of Dental Care Departments in Dental Hospital in Korea (한국 치과병원내 진료과목의 공간배분계획에 관한 연구)

  • Jeong, Taejong;Choi, Jaepil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.27-36
    • /
    • 2017
  • Purpose: The characteristics of spatial allocation planning in dentistry through examining the dental hospitals in Korea and comparison between them are necessary for the development of planning of the dental healthcare system. This study has been started to provide basic informations such as zoning, allocation distribution, and space configuration for the planning of dental hospital architecture. Methods: Literature review of dental care departments and investigation on current status of dental hospital in Korea have been conducted. The spatial allocation and space configuration of eleven dental hospitals have been analyzed. Results: The result of this study can be summarized in three points. The first one is that dental hospitals in Korea are consisted with eight to eleven dental care departments and they are divided with the horizontal allocation type with three to four departments in a floor for the spatial communication or the vertical allocation type with a department in each floor for the independent space. The second one is that oral medicine and oral maxillofacial radiology are located near the main entrance, orthodontics and pedodontic dentistry in lower level, prosthodontics in upper level, and conservative dentistry and periodontics have no specific spatial consideration. The third one is that the factors to consider the allocation planning are zoning for examination & diagnosis, basic practice, adolescence, surgery, circulations for patient, dentist, staff, different access for department like as easy access for reception and pedodontic dentistry, enclosure space for prosthodontics and surgery, frequency of visit and treatment care time, and change of treatment concept from treatment department to disease control corporative practice. Implications: This study is the starting point for the research of spatial configuration in dentistry and it is necessary to analyze the architectural planning to develop the dental healthcare system.

A Study on the Perceptual Characteristics of Upper-class Houses in the Joseon Dynasty through Sectional Analysis - Focused on the Kyeong Buk Region 'ㅁ' Shape of House - (단면분석을 통한 조선시대 상류주택 안마당의 시지각 특성에 관한 연구 - 경북지방 'ㅁ'자형 주택을 중심으로 -)

  • Sung, Jae-Joong;Lee, Seung-Yong
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.4
    • /
    • pp.9-16
    • /
    • 2022
  • The purpose of this study is to analyze the cross-sectional ratio of the courtyard, an external space that not only was used as a workplace, shelter, and playground in our lives, but also gave symbolic meaning to Koreans. Since the beginning of 2000, Hanok began to receive rapid attention from people, and Hanok construction and remodeling were actively carried out in urban and rural areas. In particular, Bukchon and Seochon in Seoul, around Cheonmachong in Gyeongju, and Hanok Village in Jeonju became popular places related to hanok, and Gyeongju, Buyeo, Gongju, and Iksan were designated as ancient districts to encourage the construction of hanok. However, although hanok is being built with national trends, support, and interest, attention is focused only on the external form, materials, and convenience of use, and the composition and system of the external space have not been properly reviewed. Therefore, this study aims to understand the functions and meanings of the yard in traditional housing, and to analyze the proportion of the height of the building surrounding the yard and the depth of the yard in terms of closure and opening. In addition, the system and characteristics of the external space of traditional architecture felt by this can be used as basic data in designing traditional architecture.

Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System (다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용)

  • Yoo, Jae-Ill;Lee, Dong-Ho;Hong, Jin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • The multi-level profile system is designed to measure the vertical profile of $H_2O$ and $CO_2$ concentrations in the surface layer to estimate the storage effects within the plant canopy. It is suitable for long-term experiments and can be used also in advection studies for estimating the spatial variability and vertical gradients in concentration. It enables the user to calculate vertical fluxes of water vapor, $CO_2$ and other trace gases using the surface layer similarity theory and to infer their sources or sinks. The profile system described in this report includes the following components: sampling system, calibration and flow control system, closed path infrared gas analyzer(IRGA), vacuum pump and a datalogger. The sampling system draws air from 8 inlets into the IRGA in a sequence, so that for 80 seconds air from all levels is measured. The calibration system, controlled by the datalogger, compensates for any deviations in the calibration of the IRGA by using gas sources with known concentrations. The datalogger switches the corresponding valves, measures the linearized voltages from the IRGA, calculates the concentrations for each monitoring level, performs statistical analysis and stores the final data. All critical components are mounted in an environmental enclosure and can operate with little maintenance over long periods of time. This report, as a practical manual, is designed to provide helpful information for those who are interested in using profile system to measure evapotranspiration and net ecosystem exchanges in complex terrain.

Effect of Latent Heat Material Placement on Inside Temperature Uniformity of Insulated Transfer Boxes (단열용기의 잠열재 배치에 따른 내부 온도 균일성에 대한 영향)

  • HyungYong Ji;Dong-Yeol Chung;Seuk Cheun Choi;Joeng-Yeol Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.27-33
    • /
    • 2023
  • An optimized design of the transportation insulated box must be considered to control the thermal damage in order to maintain the fresh condition for temperature-sensitive medicine and frozen food safety. The inside temperature of the insulated box is a natural convection enclosure state, thermal stratification naturally occurs as time passes in case of with outside heat load. The latent heat material (LHM) placement inside the box maintains the target temperature of the product for temperature fluctuations during transport, and LHM application is a common and efficient method. In this work, inside temperature stratification in an insulated box depending on the LHM pack position is numerically simulated and experimented. The insulated box is made up of vacuum insulation panel (VIP), and LHM modules are placed over six faces inside the box, with the same weight. The temperature curves for 72 hrs as experiment results clearly show the temperature stratification in the upper, middle, and lower at the LHM melting time region. However, the temperature stratification state is uniformly changed in accordance with the condition of the upper and lower placement weight of the LHM pack. And also, the temperature uniformity by changed placement weight of LHM has an effect on maintaining time for target air temperature inside the box. These results provide information on the optimized design of the insulated box with LHM.

Characteristics of Partial Discharge Under HVDC in SF6 Gas (SF6 가스 중 직류 고전압 하에서 부분방전 특성)

  • Kim, Min-Su;Kim, Sun-Jae;Jeong, Gi-Woo;Jo, Hyang-Eun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.238-243
    • /
    • 2014
  • This paper dealt with the measurement and analysis of partial discharge (PD) under high voltage direct current (HVDC) in SF6 gas. Electrode systems such as a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack on epoxy plate and a free particle (FP) were fabricated to simulate the insulation defects. The analysis system was designed with a Time-Frequency (T-F) map algorithm programed based on LabVIEW. This can arrange the acquired PD pulses into frequency and time domain. A HVDC power source is composed of a transformer (220 V/50 kV), a diode (100 kV) and a capacitor (50 kV, 0.5 ${\mu}F$). The gap between the electrodes is 3 mm, and the $SF_6$ gas was set at 5 bar. PD pulses were detected by a 50 ${\Omega}$ non-inductive resistor. In the analysis, PD pulses were distributed below 0.5 MHz and 20 ns ~ 35 ns for the POC, 0.7 MHz ~ 1.7 MHz, below 0.6 MHz and 10 ns ~ 40 ns and 60 ns ~125 ns for the POE, below 0.1 MHz and 135 ns ~ 215 ns for the crack, and below 1.6 MHz and 250 ns for the FP.

A Study on Perceived Problems of and Improvement Measures for Asbestos Abatement Companies in Support of Related Policies (석면 해체 및 제거 업체가 느끼는 관련 제도의 문제점 및 개선방안에 관한 연구)

  • Chang, Jaepil;Rho, Youngman;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.28-38
    • /
    • 2020
  • Objectives: The purpose of this study is to identify the perceived problems of and suggest improvement measures for asbestos abatement companies in support of asbestos-related systems and policies. Methods: For this study a questionnaire was prepared consisting of current work (two questions), the contribution and necessity of a risk assessment system for asbestos abatement (two questions), and problems with and improvement measures for systems and policies (nine questions). The questionnaires were sent to 2,170 asbestos abatement companies and were returned by 83 companies (return rate = 3.8%). We conducted frequency analysis, ANOVA, and a Chi-squared test at the 5% significance level. Results: Asbestos abatement companies expressed difficulties with complying with wet work (43% of unenrolled managers), negative pressure enclosure (36% of all respondents), and installation and use of decontamination units (26% of all respondents) as stipulated in the relevant regulations. In addition, 43% of the respondents expressed concerns that the expertise of the company was not considered during bidding for asbestos abatement and hoped that an advantage (e.g., bid point) would be given to the upper grades for asbestos risk assessment (38%). Asbestos abatement companies generally rented and used negative pressure devices (including negative pressure recording devices) and suggested that periodic calibration (32%) is needed to ensure the performance of the rented equipment. Finally, the respondents asked for clear definitions for three situations specified in the Occupational Safety and Health Acts: (1) temporarily leaving the asbestos abatement workplace; (2) tasks with less airborne asbestos; and (3) physically breaking or cutting using a machine. Conclusions: The problems and improvement measures identified in this study of asbestos abatement companies can be utilized as fundamental information for the improvement of the systems and policies for safe asbestos abatement.

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • v.6 no.4
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.

A Study on Method to Decide Location to Install Integrated Standard Controller Utilizing Centroid Method (센트로이드기법을 활용한 통합표준제어기 설치위치 결정방법에 관한 연구)

  • Kim, Gyeong-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.4
    • /
    • pp.1-9
    • /
    • 2015
  • Since logical ground and method to deduct location to install Integrated Standard Controller under development to combine physically and functionally multiple enclosures of controllers for various ITS equipments on streets into one enclosure, there are much difficulty to apply it to site. Particularly we need to establish standardized methodology to deduct optimal location to integrate individual controllers installed dispersedly on streets such as node part and line part. Accordingly this study has the purpose of suggesting more reasonable and efficient methodology to determine location for Integrated Standard Controller to be developed newly. For this, new solution has been searched by using centroid which is utilized to decide facility location in urban planning. As the result of analysis, central point among centroid, in which equal connection to each equipment is possible is proved to be the most reasonable and correct coordinate and zone is proposed as installation location through designating coordinate system. The methodology suggested by this study seems to have high degree of utilization in site according to expansion of integrated standard controller market.