• Title/Summary/Keyword: Emergency Power Generation

Search Result 80, Processing Time 0.023 seconds

Application and Evaluation of Emergency Rates in Overhead Transmission Lines (가공송전선로의 비상용량 응용과 평가)

  • Kim, Sung Duck
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.442-446
    • /
    • 2014
  • A method for applying emergency ratings to improve the reliability of power supply in ACSR overhead transmission lines is described in this paper. Due to re-regulate power industry, most power companies worldwide as well KEPCO have been searching for only economical strategies without new investment. Power demand was rapidly increasing, however, generation amount did not follow sufficiently. Hence in order to increase the transmission capacity for the existing transmission lines in case of peak load, or contingency in transmission lines, an application method of emergency ratings such as short or long term rating is proposed. If applying long term emergency rating instead of static line rating for the period of a peak load, power transmission can be increased to 10 % or more. Furthermore, it was shown that emergency rating can be effectively used in the contingency of double-circuit transmission lines and/or overload cases.

Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System (이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발)

  • Jeong, Byoung-Chang;Kim, Hee-Jung;Chung, Yong-Ho;Jeon, Young-Soo;Kwak, No-Hong;Song, Seung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

Analysis of energy-saving effects of recirculation aquaculture system using seawater source heat pumps and solar power generation (해수 열원 히트펌프와 태양광 발전을 이용한 순환여과식 양식장의 에너지 절감 효과 분석)

  • Jong-Hyeok RYU;Hyeon-Suk JEONG;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.2
    • /
    • pp.194-206
    • /
    • 2024
  • This study focuses on analyzing the energy-saving effects of the recirculation aquaculture system using seawater source heat pumps and solar power generation. Based on the thermal load analysis conducted using the transient system simulation tool, the annual energy consumption of the recirculation aquaculture system was analyzed and the energy-saving effects of utilizing the photovoltaic system was evaluated. When analyzing the heat load, the sea areas where the fish farms are located, the type of breeding tank, and the circulation rate of breeding water were taken into consideration. In addition, a method for determining the appropriate capacity for each operation time was examined when applying the energy storage system instead of the existing diesel generator as an emergency power, which is required to maintain the water temperature of breeding water during power outage. The results suggest that, among the four seas considered, Jeju should be estimated to achieve the highest energy-saving performance using the solar power generation, with approximately 45% energy savings.

On-line Stabilizing Control Scheme for Power System (On-line 안정화 제어기법)

  • Oh, Tae-Kyoo;Kim, Hak-Man;Suh, Eui-Suk;Kim, Il-Dong;Kim, Yong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.903-906
    • /
    • 1997
  • When large capacity generation stations that consist of several large units tend to pull out of step from main power system, stabilizing control scheme as emergency control for preventing loss of synchronism of the whole stations with the remaining system is devided into two steps that the first step is to perform on-line prediction for out-of-step and the next step is on-line calculation of the amount of generation shedding for the rest of generators to be in step when out of step is expected. This paper presents on-line prediction scheme for out-of-step based on P-$\delta$ curve estimation using real-time measurement and on-line calculation of generation shedding. The proposed stabilizing scheme was applied to case study of real power system and the results obtained by the method compare well with the results by simulation.

  • PDF

A Study on the Emergency Control Algorithm for Viability Crisis of Power System (계통사고시 장해경감을 위한 긴급제어 알고리즘에 관한 연구)

  • 송길영;이희영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.9
    • /
    • pp.591-599
    • /
    • 1988
  • After the short-term dynamics due to the major disturbance are over, the power system may lead to viability crisis state wherein there is possibility of cascading damage. This paper presents an emergency control algorithm to alleviate the obstacles of system frequency or bus voltage during the viability crisis state. The algorithm considers the effects of controlling reactive power sources for load shedding and generation reallocation in order to alleviate the obstacles. The problem is decomposed into a subproblem I and a subproblem II. The former minimizes system frequency deviation from nominal value and the latter voltage violation of load buses. The optimization problem is solved by a reduced gradient technique which can handle a great number of inequality constraints more easily. It has been verified that the use of the proposed algorithm for IEEE 14 bus system alleviates the obstacles efficiently during the viability crisis.

  • PDF

An Adaptive Reclosing Algorithm Considering Distributed Generation

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.651-659
    • /
    • 2008
  • Autoreclosing techniques have been used in power systems to maintain system stability and continuity of supply. Environmental and economical issues have driven significant increases in the development of distributed generation (DG). DG connected to distribution systems, however, may impose negative influences with respect to power quality, protection, and stability, because DG can cause some challenges to protection, especially to reclosing. For this reason, in order to improve the reliability and safety of the distribution system, the rules and guidelines suggest that the DG system needs to be rapidly disconnected from the system before reclosing. We present, in this paper, an adaptive reclosing algorithm considering the DG. The algorithm consists of an angle oscillation's judgment, the emergency extended equal-area criterion (EEEAC), the calculation of an optimal reclosing time, and a reconnection algorithm. Our simulation results for three different DG technologies with Electromagnetic Transient Program (EMTP) indicate that we can maintain transient stability while the DG is protected against disturbances.

An Adaptive Reclosing Technique Considering the Distributed Generation (분산전원을 고려한 적응적 재폐로 기법)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yeo, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.227-232
    • /
    • 2007
  • The autoreclosing is applied to power system for maintaining system stability and continuity of supply. Developments on distributed generation(DG) grows significantly by environmental issues and economical issues. If the DG is connected to distribution system, the DG influences the technical aspects such as power quality, protection and stability. It causes the challenges to protection, especially to reclosing. In order to achieve reliability and safety of the distribution system, the rules and guidelines suggest that the DG units should be rapidly disconnected from the network before the reclosing. If the DG is disconnected whenever the fault occurs, it cannot be utilized effectively. This paper presents the adaptive reclosing algorithm considering the DG. The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Expanded Equal-Area Criterion), calculation of optimal reclosing time and re-connection algorithm. The simulation is implemented for the DG technology by using EMTP MODELS. The simulation results show that the transient stability is maintained and the DG is protected against disturbance.

A Study on the Emergency Control Algorithm for Viability Crisis of Power System (계통사고시 장해 경감을 위한 긴급제어에 관한 연구)

  • Song, Kil-Yeong;Lee, Hee-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.129-132
    • /
    • 1987
  • This paper presents an emergency control algorithms for viability crisis following abnormal condition as well as a sudden major supply outage and line outage. The algorithm considers the effect of voltage-reactive power control for determining the load shedding quantities and generation reallocation. The problem is decomposed into a P-problem and a Q-problem. The former minimizes system frequency deviation from nominal value and the latter minimizes voltages violation of load buses. The optimization problem is solved by a reduced gradient technique which can handle a great number of inequality constraints very efficiently. It has been found that the use of the proposed algorithm for 6-Bus system restore the abnormal system during the viability crisis to the normal state.

  • PDF

Hard rock TBM project in Eastern Korea

  • Jee, Warren W.
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.10a
    • /
    • pp.33-41
    • /
    • 2008
  • The longest tunnel has been halted at Daekwanryung by the failure of the host country of the Winter Olympiad in 2014, but modern High-Power TBM will come to Korea to excavate these long tunnels to establish the better horizontal connection between the western and eastern countries to improve the strong powerful logistic strategy of Korean peninsula. Train operation provides a key function of air movements in a long underground tunnel, and heat generation from transit vehicles may account of the most heat release to the ventilation and emergency systems. This paper indicates the optimal fire suppress services and safety provision for the long railway tunnel which is designed twin tunnel with length 22km in Gangwon province of Korea. The design of the fire-fighting systems and emergency were prepared by the operation of the famous long-railway tunnels as well as the severe lessons from the real fires in domestic and overseas experiences. Designers should concentrate the optimal solution for passenger's safety at the emergency state when tunnel fires, train crush accidents, derailment, and etc. The optimal fire-extinguishing facilities for long railway tunnels are presented for better safety of the comfortable operation in this hard rock tunnel of eastern mountains side of Korea. Since year 1900, hard rock tunnel construction has been launched for railway tunnels in Korea, tunnels have been built for various purposes not only for infrastructure tunnels including roadway, railway, subway, and but also for water and power supply, for deposit food, waste, and oils etc. Most favorable railway tunnel system was discussed in details; twin tunnels, distance of cross passage, ventilation systems, for the comfortable train operations in the future.

  • PDF

Study on the mobile phone case for self-power generation (자가발전용 휴대폰 케이스에 관한 연구)

  • Kim, Jin Ho;Park, Chang Hyung;Han, Seung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.8-12
    • /
    • 2017
  • This paper presents the mobile phone case for self-power generation and recharge for emergency calls or text messages at the discharge of a battery. If the user shakes his smart phone case, the interaction of electromagnetic coil and permanent magnet in an electric generator produces electric energy, which charges the lithium-ion battery. This enables the user to give a few calls or text messages. In addition, the vibration energy from humans walking at a frequency of 2 ~ 3Hz charges the battery. The electric generator was simulated using MAXWELL, a commercial electromagnetic analysis program, to analyze the electric power generation. Finally a prototype of the mobile phone case for self-power generation was built based on the analysis and its performance was verified.