• 제목/요약/키워드: Elevator Car

검색결과 44건 처리시간 0.023초

엘리베이터 카 내부 기류분포에 관한 열 유동해석 (Thermal and Fluid Analysis on Air Distribution in a Elevator Car)

  • 정경택;이중섭
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.56-62
    • /
    • 2020
  • The purpose of this study is to observe the visualization of the flow field for air flow distributed in the car from the ventilation fan installed in the ceiling of the passenger elevator car through the numerical analysis using computational fluid dynamics. STAR-CCM+, which is a code used for the numerical analysis, was used to predict the airflow distribution inside the elevator car. The numerical analysis of the distribution of the air current in the elevator was carried out. As a result, the analysis results for each point and the visualization of the air current distribution and the temperature distribution in the elevator car and were obtained. It was found that heat transfer was actively occurring inside the car due to the influence of the flow field discharged from the ventilation vent installed in the ceiling in the elevator car, and especially the convection heat transfer of Model-2 was more active than that of Model-1. As a result, the temperature distribution inside the car was found to be relatively low. In addition, the temperature distribution at a cross-section of 1700mm height in the elevator car shows that Model-2 is the location of the ventilation vent which makes people feel more comfortable.

엘리베이터 실내공기질의 특성 기초조사 (A Study on the Characteristics of Indoor Air Quality in Elevator)

  • 박정호;추연규;서정민
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.

유압식 엘리베이터용 에너지 저감장치의 개발에 관한 연구 (A Study on the Development of an Energy Saving Unit for a Hydraulic Elevator)

  • 조인성
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2106-2112
    • /
    • 2013
  • 기존의 유압식 엘리베이터에서, 엘리베이터 카는 하강 제어 밸브에 의해 하강하며, 작동유의 유압 에너지는 하강행정 동안 손실 될 수밖에 없다. 본 연구에서는 하강행정 동안 손실되는 유압 에너지를 회수하기 위해서 유압식 엘리베이터용 하이브리드 형 에너지 저감 장치에 대해서 연구하였다. 회수된 에너지는 전기 에너지로 변환하여 저장하고, 저장된 에너지는 엘리베이터의 상승행정 동안에 보조 동력으로 사용하거나 다른 부품의 주동력으로 사용할 수 있다. 본 연구의 결과들은 에너지 저감 장치의 출력 특성이 안정적이고 양호하다는 것을 보여주고 있으며, 본 연구를 통하여 유압식 엘리베이터의 하강행정 동안 손실되는 에너지를 회수하는데 성공하였으며, 회수된 에너지를 재사용하는데 매우 유용하다는 것을 확인하였다.

엘리베이터 하중시험 대체 검사기법 개발 (New Inspection Skill for Load-test of Hydraulic Elevator without Actual Loads)

  • 허윤섭;엄용기
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.127-132
    • /
    • 2013
  • In order to check traction of the elevator, the load-test is positively necessary on the inspection of elevator in Korea. So actual loads are used in the elevator car for the load-test. However, some of advanced countries in Europe, for example Germany, are using the alternative method with no load test instead of traditional load-test. Commonly hydraulic elevator, compared to passenger elevator is mainly used for loading heavy weights. It requires a great deal of labor to carry out load-test. The reason is why we developed a new inspection skill for the load-test of hydraulic elevator without actual loads. The results of studies show that the new method of the load-test can be replace the traditional load-test.

통합 제어 시스템에서의 엘리베이터 위치 제어 성능 개선 (Improvement of elevator position control performance in unified control system)

  • 류형민;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.34-36
    • /
    • 2002
  • This paper addresses an elevator position control scheme in unified control system. Conventional systems have employed independent micro-processors for speed, car, and group control respectively and the car controller generates a velocity command by combining the time-based and distance-based velocity pattern. In this scheme, it is inevitable that an elevator creeps in the vicinity of target floor, or stops abruptly. The proposed control system employs only one high-performance micro-processor, which can execute the car and group control as well as the speed control. It simply generates the desired position trajectory based on time and on-line corrects a velocity pattern to make the position error be zero. Experimental results show the feasibility of the proposed control scheme.

  • PDF

승객용 승강기의 재해예방에 관한 연구 (Accident Prevention Counterplen of the Elevator for the Passenger)

  • 권오헌;고성석;윤유성
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.106-111
    • /
    • 2002
  • Recently the car and elevator accidents as well as the fire, explosion and collapse increased. The passenger elevator accident from 1993 year to 2001 year has about 56.7% of total accidents and the human victims of 180 according to the Korea Elevator Safety Institute. Accident cause and prevention were investigated for the elevator having the fall, impact and narrowness accident types. The prevention and protection methods of the elevator accident from analysis results were suggested by comparing and analogizing the accident statistics about the accident investigation of the passenger elevator according to the elevator accidents.

승강기 Car용 고속응성 배터리 충전시스템에 적합한 제어알고리즘 (A Control Algorithm Suitable for High-speed Response Battery Charging System for Elevator Car)

  • 이정환;황보찬;박성준;박성미;고재하
    • 한국산업융합학회 논문집
    • /
    • 제25권6_2호
    • /
    • pp.1071-1081
    • /
    • 2022
  • As the demand for high-rise buildings increases, the demand for high-speed elevators is also increasing. In order to make a high-speed elevator, a method is needed to reduce the weight of the elevator's components, which is a constraint on the increase in speed. As a measure to reduce the weight, it is possible to remove the traveling cable for power and signal supply. Since the weight of the traveling cable varies depending on the position of the carriage, it is difficult to compensate the weight using the counter weight. The power supply is a structure in which a brush-rail type power input terminal is installed in the elevator hoistway to receive power in a contact-type manner while the carriage is moving. If a small-capacity ESS is installed in a passenger car, power can be supplied uninterruptedly inside the passenger car. A small-capacity ESS charging system to be applied to such an elevator system is required to perform several functions. First, the passenger Car must be able to charge as much as possible even during high-speed operation. A control algorithm with high responsiveness is required because charging starts and ends repeatedly by the partially installed input power stage. In addition, if the input-side line impedance is large due to the structure of the system and the response characteristic is increased, the stability of the system may be lowered. Accordingly, in this paper, we propose a control algorithm that has a stable steady-state output while having a fast response in a transient state. To verify the proposed control algorithm, simulation was conducted using PSIM, and the performance of the controller was verified by manufacturing a prototype buck conveter charger.

스마트 센서를 이용한 선박용 승강기 실시간 모니터링 시스템의 구현 (Implementation of Real-time Monitoring System for Marine Elevator using Smart Sensors)

  • 이우진;임재홍
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.405-410
    • /
    • 2016
  • Elevator industry is a field that is mechanical, electrical and electronic technology and constantly requires inspection and maintenance considering various applications and various types. Recently, various elevator control and monitoring technologies with IT are developing for elevators on land. But technologies with IT have been hardly done in marine elevator that is consistently assured safety and reliability of life cycle for its parts in poor environment. In this paper, we implemented embedded main controller, floor controller and car controller that meet the requirements and use NMEA network protocol by analyzing home and abroad integrated elevator operation and management systems. Especially, we secured reliability of maintenance by real-time fault diagnosis and control that was implemented with limit switch, gyro sensor, temperature/humidity/barometric pressure sensor and fire detection sensor thinking over the environmental conditions of terrestrial and marine elevator.

엘리베이터 위치제어를 위한 속도패턴 발생 (Velocity Pattern Generation for the Position Control Elevator)

  • 김경서;박창훈;강기호;한권상
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.616-623
    • /
    • 1999
  • 엘리베이터의 속도패턴은 출발시부터 목표 위치 근처에 다다를 때까지의 시간기준 속도패턴과 정밀한 정위치 정지를 위한 거리기준 속도패턴등로 이루어진다. 시간기준 속도패턴에서 거리기준 속도패턴으로 절환시 속도와 가속도의 급격한 변화가 없도록 하여야 패턴 절환시의 충격을 최소화하여 안락한 승차감을 얻을 수 있다. 본 논문에서는 속도패턴 절환 시 항상 속도와 가속도가 연속이 되도록 하고, 또한 목표 위치로의 수렴 속도를 개선한 새로운 엘리베이터 속도패턴 발생 방법을 제시한다.

  • PDF

화재 시 승강기를 이용한 피난에 관한 연구 (A Study on escape using elevators in fire emergency)

  • 정의수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2007년도 추계학술대회
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF