저전압 DC 배전시스템 구성요소의 부하 모델링 (Modeling of Load Element for a Low Voltage DC Distribution System)

  • 권기현;한준;오윤식;김응상;김철환
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.113-121
    • /
    • 2014
  • At the end of the 19th century, a battle known as the War of the Currents was fought over how electricity would be generated, delivered, and utilized. In this day and age, there has been a growing interest in Green Growth policies as countermeasures against global warming. As a result of these policies, the use of new and renewable energy needed a power converter to replace fossil fuels has expanded. To reduce power consumption through high efficiency of conversion, Low Voltage DC (LVDC) distribution systems are suggested as an alternative. In a DC distribution system, DC loads are very efficient due to decrease the stages of power conversion. If the LVDC distribution system is adopted, not only DC load but also existing AC loads should be connected with LVDC system. Thus, the modeling of two loads is needed to analyze the DC distribution system. This paper, especially, is focused on the modeling of resistive load and electronic load including power electronic converters using ElectroMagnetic Transient Program (EMTP) software.

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

터치키 응용을 위한 풀 디지털 정전용량 센서 (A Full Digital Capacitive Sensor for Touch Key Applications)

  • 성광수;이무진
    • 대한전자공학회논문지SD
    • /
    • 제46권6호
    • /
    • pp.25-30
    • /
    • 2009
  • 본 논문에서는 터치키에 응용할 수 있는 풀 디지털 방식의 정전용량 센싱 기법을 제안한다. 제안된 회로는 측정하고자 하는 정전용량 두 개와 두 정전용량 사이 저항으로 구성된다. 각 정전용량과 저항으로 지연을 측정한 후 두 지연의 차이로 측정하고자 하는 두 정전용량의 차이를 구하는 방식으로 동작전압, 온도, 습도와 같은 동작환경변화의 영향을 완화시킬 수 있는 장점이 있다. 실험결과 제안된 방식의 정전용량 해상도가 1.02pF이어서 터치키에 적용할 수 있음을 보였다.

하이퍼큐브 분산 시스템에서 향상된 부하분산에 관한 연구 (A Study on Adbanced Load Balancing for Hypercube distributed System)

  • 유재욱;박인갑;김중민
    • 전기전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.87-93
    • /
    • 2002
  • 본 논문에서는 n 차원의 하이퍼큐브(hypercube) 구조의 분산 시스템에서 새로운 부하분산 알고리즘을 제안하였다. 제안된 알고리즘은 인접노드에게만 과부하 노드의 부하를 전송하여 발생되었던 blocking phenomenon을 억제하였으며 processor thrashing을 방지하기 위하여 한 프로세서에 모든 프로세서의 정보를 모아 실행하는 중앙집중형 알고리즘의 장점을 응용하였다. 제안된 알고리즘의 성능 평가를 위하여 컴퓨터 모의실험을 수행하고 다른 알고리즘과 비교하였다. 2차원 하이퍼큐브 분산 시스템의 경우에는 각 알고리즘의 부하분산 결과가 큰 차이를 보이지 않았으나 3차원과 4차원의 경우에는 제안된 알고리즘이 보다 나은 결과를 보여주었다.

  • PDF

고성능 CMOS LDO 레귤레이터 설계 (Design of a High-Performance CMOS LDO Regulator)

  • 심상미;박준규;강현철;유종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.187-188
    • /
    • 2007
  • This paper describes a simple and high-performance LDO regulator designed using a $0.18{\mu}m$ CMOS process. It is designed to provide a regulated voltage for on-chip small loads instead of for off-chip heavy loads. Since the load capacitance is very small in this applications, the frequency compensation can be easily achieved without a buffer. The designed LDO drives a load current up to 15mA and dissipates only 12uA quiescent current. The line regulation is and the load regulation is for a 9mA load step. The PSRR at 10kHz is 54dB.

  • PDF

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.

전력시스템을 위한 서브시스템의 제어 (Control of the Subsystem for a Power System)

  • 이용근
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.404-409
    • /
    • 2009
  • A DC power system has many loads with various functions. In particular, these sizable loads take the form of power electronic converters. When they are tightly regulated, the loads appear as constant power loads and result in negative incremental input impedance. Under certain conditions the effect of such loads on the power system is causes instability. In this paper, converter with a large storage capacitor and a lag compensator is proposed as a DC bus conditioner to mitigate the voltage transients on the bus. In addition, the proposed control approach has the advantage of performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. Simulation and experimental results showed that the proposed control method was operated well in a small-scale DC power system that contained subsystems with constant power characteristics, such as DC/DC converters and electrical drives.

ELM을 이용한 주거용 부하의 부하모델링 기법 개발 (Development of ELM based Load Modeling Method for Residential Loads)

  • 정영택;지평식
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.29-34
    • /
    • 2012
  • Due to the increasing of nonlinear loads such as converters and inverters connected to the electric power distribution system, and extensive application of harmonic generation sources with power electronic devices, disturbance of the electric power system and its influences on industries have been continuously increasing. Thus, it is difficult to construct accurate load model for active and reactive power in environments with harmonics. In this research, we develop a load modeling method based on Extreme Learning Machine(ELM) with fast learning procedure for residential loads. Using data sets acquired from various residential loads, the proposed method has been intensively tested. As the experimental results, we confirm that the proposed method makes it possible to effective estimate active and reactive powers than conventional methods.

비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현 (The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads)

  • 장목순;이후찬;김상훈;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

Time-variant structural fuzzy reliability analysis under stochastic loads applied several times

  • Fang, Yongfeng;Xiong, Jianbin;Tee, Kong Fah
    • Structural Engineering and Mechanics
    • /
    • 제55권3호
    • /
    • pp.525-534
    • /
    • 2015
  • A new structural dynamic fuzzy reliability analysis under stochastic loads which are applied several times is proposed in this paper. The fuzzy reliability prediction models based on time responses with and without strength degeneration are established using the stress-strength interference theory. The random loads are applied several times and fuzzy structural strength is analyzed. The efficiency of the proposed method is demonstrated numerically through an example. The results have shown that the proposed method is practicable, feasible and gives a reasonably accurate prediction. The analysis shows that the probabilistic reliability is a special case of fuzzy reliability and fuzzy reliability of structural strength without degeneration is also a special case of fuzzy reliability with structural strength degeneration.