• Title/Summary/Keyword: Electronic Load

Search Result 1,281, Processing Time 0.033 seconds

Intelligent Diagnosis System for an Electronic Weighting Machine (전자 저울을 위한 지능형 고장 진단 시스템)

  • 김종원;김영구;조현찬;서화일;김두용;이병수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.78-82
    • /
    • 2001
  • Electronic Weighting Machine is used an electronic scale which has many trouble because of broken load cells. In this paper, we propose an intelligent Diagnosis System will for an electronic weighting machine using fuzzy logic. It's purpose be detect of the load cell's trouble. The electronic circuit of system, which call 'junction box', will be connected resistances in a series at circuit of Wheatstone Bridge for monitoring the condition of load cells.

  • PDF

Construct of Electronics Load System using the Multi-level Interiver Converter (다중전류레벨 인터리버 컨버터를 이용한 전자부하 시스템 구성)

  • Moon, Hyeon-Cheol;Song, Kwang-Cheol;Lee, Chang-Ho;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.989-998
    • /
    • 2020
  • Recently, demands for large-capacity electronic loads are increasing in various industries such as a reliability test for the performance of a DC power supply device or a dummy-load for improving the stability of an independent microgrid to be actively built in the future. The electronic load required in these various fields requires an operation such as a continuously variable resistance load while minimizing the switching harmonic component generated in the electric load current in order to reduce the influence of interference from the load peripheral device. Electronic loads require a system that minimizes switching current ripple for load control. Therefore, in this paper, we propose a three-level module converter structure to reduce the current ripple of an electronic load, and a multilevel interleaved power converter topology to reduce the current ripple. The validity of the proposed electronic load, 3-level 6 interleaver converter, was verified by simulation and experiment. In addition, the user's convenience was provided by applying the emotional command curve interface method.

Load Balancing Strategies for Network-based Cluster System

  • Jung, Hoon-Jin;Choung Shik park;Park, Sang-Bang
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.314-317
    • /
    • 2000
  • Cluster system provides attractive scalability in terms of computation power and memory size. With the advances in high speed computer network technology, cluster systems are becoming increasingly competitive compared to expensive parallel machines. In parallel processing program, each task load is difficult to predict before running the program and each task is interdependent each other in many ways. Load imbalancing induces an obstacle to system performance. Most of researches in load balancing were concerned with distributed system but researches in cluster system are few. In cluster system, the dynamic load balancing algorithm which evaluates each processor's load in runtime is purpose that the load of each node are evenly distributed. But, if communication cost or node complexity becomes high, it is not effective method for all nodes to attend load balancing process. In that circumstances, it is good to reduce the number of node which attend to load balancing process. We have modeled cluster systems and proposed marginal dynamic load balancing algorithms suitable for that circumstances.

  • PDF

High-Power Water-Cooled RF Load (고출력 마이크로파 수냉식 RF Load 설계)

  • Heo, Ye-Rim;Lee, Cheol-Eon;Park, Su-Yeon;Kang, Ju-Yeong;Choi, Jin Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.6
    • /
    • pp.445-451
    • /
    • 2019
  • This paper presents the design of a water-cooled radio-frequency(RF) load with simple structure, for use in the ultrahigh-frequency (UHF) band. After establishing a formula to obtain the physical properties that affect RF matching, we measure the permittivity and $tan{\delta}$(Loss tangent) of tap water. Because the temperature of tap water increases upon applying high power, we measure the permittivity and $tan{\delta}$ for all changes in the temperature of tap water. In order to reduce the length of the water-load, molybdate with high $tan{\delta}$ is mixed with tap water. The loss tangent of the mixture is found to be approximately 26 times higher than that of tap water. Finally, we manufacture a water-cooled RF load and measure its characteristics. A reflection coefficient of -19 dB and bandwidth of 15 % is obtained at 460 MHz.

Evaluation of Load Rejection to House Load Test at 50% Power for UCN 3

  • Lee, Chang-Gyun;Suk whun Sohn;Sohn, Jong-Joo;Seo, Jong-Tae;Lee, Sang-Keun;Kim, Youngsung;Nam, Kyu-Won;Jung, Yang-Mook;Chae, Kyeong-Sik
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.398-403
    • /
    • 1998
  • The Load Rejection to House Load test at 50% power was successfully peformed during the UCN 3 PAT period. In this test, all plant control systems automatically controlled the plant from 50% power to house load operation mode. The KISPAC code, which was used in the performance analysis during the design process of UCN 3&4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design.

  • PDF

Experimental Study on Cooling Load Forecast Using Neural Networks (신경회로망을 이용한 일일 냉방부하 예측에 관한 실험적 연구)

  • Shin, Kwan-Woo;Lee, Youn-Seop;Kim, Yong-Tae;Choi, Byoung-Youn
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.61-64
    • /
    • 2001
  • The electric power load during the peak time in summer is strongly affected by cooling load. which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data approached to the actual data.

  • PDF

Load Balancing Strategy for P2P VoD Systems

  • Huang, Guimin;Li, Chengsen;Liu, Pingshan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4207-4222
    • /
    • 2016
  • In a P2P (Peer-to-Peer) VoD (video-on-Demand) streaming system, the nodes' load is an important factor which affects the system performance. In the system, some nodes may receive too many requests, which leads to overload. On the other hand, some other nodes may receive too few requests, which leads to low utilization. Therefore, designing a reasonable load balancing strategy is important. However, existing related studies cannot handle this problem effectively, because they don't have an efficient dynamic load information management mechanism, and they don't distinguish the difference of requests when transfer the nodes' load. In this paper, to manage the dynamic load information efficiently, we design a load management table for each node. Based on the load information, we propose a load balancing strategy which uses a request migration algorithm (LBRM). Through simulations, our scheme can handle the load imbalance problem effectively and improve the users' playback fluency.

Development and Evaluation of the Road Energy Harvester According to Piezoelectric Cantilever Structure and Vehicle Load Transfer Mechanism (압전 캔틸레버 구조와 차량하중 전달방법에 따른 도로용 에너지 하베스터의 설계 및 평가)

  • Kim, Chang-Il;Kim, Kyung-Bum;Jeong, Young-Hun;Lee, Young-Jin;Cho, Jeong-Ho;Paik, Jong-Hoo;Kang, In-Seok;Lee, Moo-Yong;Choi, Beom-Jin;Park, Shin-Seo;Cho, Young-Bong;Nahm, Sahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.773-778
    • /
    • 2012
  • A road energy harvester was designed and fabricated to convert mechanical energy from the vehicle load to electrical energy. The road energy harvester is composed of 16 piezoelectric cantilevers. We fabricated prototypes using a vehicle load transfer mechanism. Applying a vehicle load transfer mechanism rather than directly installing energy harvesters under roads decreases the area of road construction and allows more energy harvesters to be installed on the side of the road. The power generation amount with respect to the vehicular velocity change was assessed by installing the vehicle load transfer mechanism form and underground form. The energy harvester installed in the underground form generated power of 4.52 mJ at the vehicular velocity of 50 km/h. Also, power generation of the energy harvester installed in the vehicle load transfer mechanism form was 48.65 mJ at the vehicular velocity of 50 km/h.

Short-term Electric Load Forecasting Based on Wavelet Transform and GMDH

  • Koo, Bon-Gil;Lee, Heung-Seok;Park, Juneho
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.832-837
    • /
    • 2015
  • The group method of data handling (GMDH) algorithm has proven to be a powerful and effective way to extract rules or polynomials from an electric load pattern. However, because it is nonstationary, the load pattern needs to be decomposed using a discrete wavelet transform. In addition, if a load pattern has a complicated curve pattern, GMDH should use a higher polynomial, which requires complex computing and consumes a lot of time. This paper suggests a method for short-term electric load forecasting that uses a wavelet transform and a GMDH algorithm. Case studies with the proposed algorithm were carried out for one-day-ahead forecasting of hourly electric loads using data during the years 2008-2011. To prove the effectiveness of our proposed approach, the results were evaluated and compared with those obtained by Holt-Winters method and artificial neural network. Our suggested method resulted in better performance than either comparison group.

Enhancement Still Image Quality Considering Load Effect in PDP-TV (PDP의 정지영상에서 load effect를 고려한 화질 개선 방법)

  • Kim, Jin-Bok;Kang, Sung-Jin;Chien, Sung-Il
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.301-302
    • /
    • 2006
  • Load effect which occurs due to the electrode structure for PDP(plasma display panel) can seriously reduce the image quality of PDP. In this paper, we propose the method of reducing load effect in presentation images, which have the possibility of load effect, by using LUT(look-up table). The proposed method enhances the image quality of PDP by correcting load effect region of the still image.

  • PDF