• Title/Summary/Keyword: Electronic Healthcare System

Search Result 163, Processing Time 0.032 seconds

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

Design of Acute Heart Failure Prevention System based on QRS Pattern of ECG in Wearable Healthcare Environment (웨어러블 헬스케어 환경에서 ECG 전기패턴 QRS을 이용한 급성 심장마비 예방 시스템)

  • Lee, Joo-Kwan;Kim, Man-Sik;Jun, Moon-Seong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1141-1148
    • /
    • 2016
  • This paper proposed a heart attack predictive monitoring system using QRS pattern of ECG for wearable healthcare. It detects abnormal heart pattern with a ECG (X, Y) coordinate pattern DB on wearable monitoring smart watch. We showed the acute heart failure prevention system and method with a proposed scheme. Especially, It proved the method which can do first aid in gold time through abnormal heart analysis with a digital ECG(X, Y) pattern information when acute heart failure occurs.

M2M Technology based Global Heathcare Platform (M2M 기반의 글로벌 헬스케어 시스템 플랫폼)

  • Jung, Sang-Joong;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.145-146
    • /
    • 2010
  • This paper proposed a new concept of global healthcare system based on M2M technology with the combination of networks by using IPv6 techniques. The proposed system consists of 6LoWPAN based wearable sensors, gateway for the connection of different networks, and server program offering health information. Thus our approach presents an intelligent system which allows direct exchange of information between machines without human assistance with the epoch-making extension of measurement environment in healthcare areas appropriately.

  • PDF

Evaluation of Electronic Pedal in Commercial Vehicles using Physiology Analysis of Electromyography (근전도 생리 분석을 이용한 상용차용 전자페달의 평가)

  • Kim, Jae-Jun;Kim, Kyung;Shin, Sun-Hye;Yu, Chang-Ho;Jeong, Gu-Young;Oh, Seung-Yong;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1434-1440
    • /
    • 2011
  • In this paper, we assessed muscular activities of lower limbs and foot pressure for car and bus drivers according to operating three electronic pedals that we developed. To analyze drivers' physical exhaustion, muscular fatigue of lower limbs was evaluated. Eleven car drivers and six urban bus drivers were participated in this experiment. The virtual driving system was used for the real driving environment. The virtual driving system was comprised of a spring seat, a steering wheel, pedals (clutch, excel and brake pedals), a manual transmission and a virtual driving simulation. For the real vibration like situation on the road, six degree of freedom motion base system was used. Measured muscles were rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius (Gn) muscles. For the quantitative muscular activities, integrated electromyography (IEMG) was analyzed. Muscular fatigues also were analyzed through the analysis of the median frequency. In addition, foot pressures were analyzed and compared through the peak and averaged pressure during the operating three developed electronic pedals. The experiments are conducted with total 17 drivers, 11 general public and 6 drivers. As a result of the analysis, electromyogram and fatigue analysis through intermediate frequency reduction for pedal-1 more efficient than other pedals. And foot pressure also was decreased. Consequently, we suggested the most efficient pedal and method to minimize the amount of cumulative fatigue.

Enhancing Privacy Protection in Steppy Applications through Pseudonymization

  • Nugroho, Heri Arum;Prihatmanto, Ary Setijadi;Rhee, Kyung Hyune
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.763-766
    • /
    • 2015
  • Smart Healthcare System as an Open Platform (Shesop) is an integrated healthcare system and have several features, one of them is Steppy Application. Steppy does count your step and display on Shesop website. In this system security issues are not properly addressed, while Personal Health Record (PHR) patient stored in the cloud platform could be at risk. In fact, the huge electronic information available online, people needs reliable and effective technique for privacy preserving. In order to improve the security of data which are displayed on the Shesop website, so that anyone who access could not tamper without permission. Recently Xu et al. showed a pseudonym scheme using smart card as a solution in e-health systems which uses discrete logarithm problem with cyclic group. In this paper, we adopt their scheme and use it application into smartphone using Near Field Communication (NFC) to construct security in Steppy apps.

Design of Interworking Technology for Heterogeneous Medical Device Networks in Smart Healthcare Environments (스마트 의료 환경에서 이기종 네트워크 간 연동 기술 설계)

  • Kim, Minjin;Lee, Seunghan;Kim, Jaesoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.4
    • /
    • pp.25-31
    • /
    • 2015
  • Smart healthcare environments which merge medical and IT technology are getting ready for the third generation centering EHR from current second generation. As a basic technology for the introduction and activation of EHR systems it requires heterogeneous network interworking techniques between various wired and wireless medical devices. Interworking technology for heterogeneous network among various medical devices is needed to introduce EHR system. The heterogeneous network interworking technology is needed for construction of a reliable data system to convert each of unstructured data into structured data. Therefore, in this paper, we identify the domestic and international trends of smart medical field and analyze the characteristics of wired and wireless communication technology that is used in a heterogeneous network. and also suggest requirements needed for interworking technology and provide interworking technology based on them. we expect that proposed method which is designed for smart healthcare environments would provide a basic architecture needed for third smart medical technology generation.

Role based access control of healthcare information system for Mobile environments (모바일 환경에 적합한 헬스 케어 정보 시스템에서의 역할기반 접근제어)

  • Lee You-Ri;Park Dong-Gue
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.3 s.35
    • /
    • pp.119-132
    • /
    • 2005
  • The health care system revolutionized by the use of information and communication technologies. Computer information processing and electronic communication technologies play an increasingly important role in the area of health care. We propose a new role based access control model for pervasive health care systems, which changed location, time, environment information. Also our model can be solved the occurrence of an reduction authority problem to pervasive health care system at emergency environment. We propose a new role based access control model for pervasive health care systems, which combines role-to-role delegations, negative permission, context concept and dynamic context aware access control. With out approach we aim to preserver the advantages of RBAC and offer groat flexibility and fine-grained access control in pervasive healthcare information systems.

  • PDF

Query Technique for Quick Network Routing changing of Mobility Sensor Node in Healthcare System (헬스케어 시스템에서 이동형 센서노드의 신속한 네트워크 라우팅 변화를 위한 질의기법)

  • Lee, Seung-chul;Kwon, Tae-Ha;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.517-520
    • /
    • 2009
  • Healthcare application system has been actively researched to apply WSN technology to healthcare area with a mobile sensor node of low cost, low power, and small size. Sensor node has the problem for transmission range of RF power and time delay of the wireless routing connectivity between sensor nodes. In this paper, we proposes a new method utilizing mobile sensor nodes with relay sensor nodes for quick network routing changing using query technique in healthcare system. A query processor to control and manage the routing changing of sensor nodes in a wireless sensor network was designed and implemented. The user's PC transmits the beacon message which will change the quick link routing according to activity status of patient in wireless sensor network. We describe the implementation for query protocol that is very effective of power saving between sensor nodes.

  • PDF

Design of healthcare system using infrared camera (적외선 열화상 카메라를 이용한 건강관리 시스템 설계방안 연구)

  • Baek, Ji-Hoon;Kim, Sang-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.1262-1263
    • /
    • 2017
  • 본 논문은 열화상 카메라를 통해 촬영 범위 내에 위치한 사람들의 체온을 측정하고 수집한 데이터를 통해 의료시설과의 연계를 통하여 지속적인 케어를 받을 수 있도록 하는 시스템에 대한 설계를 다룬다.

Development of an Electronic Document for DNR Informed Consent based on the Electronic Medical Record System (전자의무기록 기반의 심폐소생술금지 동의서의 전자서식 개발)

  • Park, Ji-Kyeong
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.99-111
    • /
    • 2016
  • Objectives : This study developed an iPad-based animation for an electronic informed consent to directly help patients prepare an informed consent. The goal was to raise patients' understanding about the contents contained in a DNR informed consent in the current medical situation in which DNR informed consents are mostly written by a guardian. Methods : The development of a DNR electronic informed consent was done in 3 stages: analysis, design and development. The analysis stage was done with a survey on the real status of preparing a DNR informed consent in a medical institution. The design stage was done with the contents in the DNR electronic informed consent through a primary and secondary Delphi survey. The development stage created a DNR electronic informed consent and evaluated it through a tertiary Delphi survey. Results : After evaluating the appropriateness of the composition of the contents, the understanding of the contents, the convenience of use, the reflection of an expert opinion, and the suitability of the application, all had scores higher than 4 points. Conclusions : The results of this study show that our proposed DNR electronic informed consent can help patients better understanding the contents of a DNR informed consent.