• 제목/요약/키워드: Electronic Acupuncture System

검색결과 54건 처리시간 0.023초

경혈 저항특성에 관한 연구(II) (A Study on the Acupuncture Point Resistance Characteristics(II))

  • 김응수;한순천;최태종;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.69-72
    • /
    • 2001
  • In this paper, we study about a acupuncture point and a non-acupuncture point resistance characteristics for acupuncture research. For this study, we devised resistance variation measurement system. This system is consist of 4-channel skin resistance measuring parts, filters, 12bit A/D convertor, 8051 micro-controller, and personal computer The developed system insert a low current to skin and obtains voltages from standard resistor that is convected to measurement circuit in series. The obtained voltage is converted to 12bit digital signal. Therefore the converted signal is changed to skin resistance by calculation in the personal computer. As the results of experiment, the resistance of acupuncture point and non-acupuncture point are different from each other. The acupuncture point has very fast current flows than the other non- acupuncture point.

  • PDF

WEB 기반 지능형 전자침 시스템 구현 (Implementation of Intelligence Electronic Acupuncture System based on WEB)

  • 박현숙;홍유식
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권3호
    • /
    • pp.93-100
    • /
    • 2018
  • 전자 침은 환자의 신체 상태 및 치료 상태를 동시에 분석함으로써 환자를 침술 기법으로 치료할 수 있는 장점이 있다. 본 논문에서는 다중 패드에 내장 된 전자 바늘 알고리즘을 제안하고 개발 하였다. 특별히, 환자의 건강 상태에 맞는 최적의 전자침 강도 자동 계산, 감지 패드 및 DSP 시스템을 사용한 전자침 제어 알고리즘을 구현 하였다. 뿐만 아니라, 본 논문에서는 환자의 개인 생체신호 정보를 수신 할 수 있는 SW 및 HW 시제품을 개발하여서, WEB 기반에서 멀티 ARRAY형 전지침 시술을 받을 수 있는 SW 및 HW 시제품을 개발 하였다.

경혈의 밀리파 자극과 그 영향에 관한 연구 (A Study on the millimeter-wave stimulation on acupuncture points and it′s biological effects)

  • 변미경;한상휘;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.129-132
    • /
    • 2002
  • In this paper, we describe a millimeter-wave radiation system developed for stimulating acupuncture points, and an analyzing system developed for monitoring the change of physiological signals after the stimulation such as ECG, skin temperature, skin potential and skin resistance. The systems are to be used to investigate the treatment efficacy and biological effects of the millimeter-wave, and eventually, can be used to study the acupuncture meridian system theory in the traditional Korean medicine.

  • PDF

침치료가 부교감신경계에 미치는 영향에 대한 문헌 고찰 (Effects of Acupuncture on Parasympathetic Nervous System: A Review of the Literature)

  • 이동화;임진웅;남상수;김용석;이상훈
    • Journal of Acupuncture Research
    • /
    • 제28권1호
    • /
    • pp.109-115
    • /
    • 2011
  • Objectives : This review is to summarize and assess the effects of acupuncture on parasympathetic nervous system(PNS). Methods and Materials : We searched two electronic databases (CNKI, PubMed) for the articles published until Oct. 2010. The randomized clinical trials (RCTs) and uncontrolled clinical trials (UCTs) were considered to be reviewed. We selected four RCTs, seven UCTs and one article which conducted both RCT and UCT, and reviewed them. The quality of RCTs was also assessed with Cochrane criteria. Results : There were four RCTs which reported acupuncture enhanced PNS, and one RCT reported acupuncture reduced PNS. Four UCTs reported acupuncture enhanced PNS, three UCTs reported acupuncture reduced PNS and one UCT reported there was no remarkable change of PNS after acupuncture. Conclusions : Although the majority of reviewed articles showed acupuncture enhance PNS, it is hard to conclude clearly how acupuncture affects PNS due to insufficient quality of trials. Therefore, more trials with strict condition need to be conducted to obviously identify the effects of acupuncture on PNS.

인터넷 기반 멀티 전자침 구현 (Implementation of Multi Electronic Acupuncture based on Internet)

  • 홍유식
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.197-202
    • /
    • 2014
  • 한의학에서는, 한의사가 환자의 질병 상태를 판단하기위해서, 환자의 혀 상태를 관찰 하는 것을 중요하게 사용한다. 본 논문에서는, 한방 치료에서 가장 많이 사용 하고 있는 맥진 및 설진 방법을 이용하여서 스마트폰 기반 한방 전자 침을 개발 하였다. 기존의 주관적인 진단을 객관화 및 과학화 하고자 한다. 뿐만 아니라, 한의원에서, 잘못된 진단 없는 객관적인 판단을 하도록 하였다. 본 논문에서는, 스마트폰 기반에서, 퍼지 논리와 추론을 사용하여 환자의 건강 상태 자동 판단 및 지능형 전자침 키트를 완성하였다. 모의실험 결과 지능을 이용한 전자침이 기존의 방법보다 효율적인 것을 입증하였다.

웹기반 스마트 전자침 시스템 (Smart Electrical Acupuncture System based on Web)

  • 홍유식
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.209-214
    • /
    • 2013
  • 인간은, 어떤 조직에 질환이 발생하게 되면, 질병이 발생한 부위는 주위 조직보다 전기 저항이 높아지게 된다. 왜냐하면, 인간은 본래부터 가지고 있는 고유의 전류가 상처 부위에서는 전기저항이 높기 때문에 전류가 잘 통과하지 못하는 특징이 있기 때문이다. 본 논문에서는, 퍼지 규칙을 이용해서 환자의 신체 상태에 적합한 전자 침술의 정확한 시간산출을 모의실험 하였다. 뿐만 아니라, 본 논문에서는 퍼지논리와 퍼지 추론 규칙을 이용하여 환자신체조건 적합한 최적의 자침시간 산출하였다.

전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구 (An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error)

  • 이병욱;오용택;장한솔;최성경;조효림;성원석;김은정
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

Trends in Acupuncture Training Research: Focus on Practical Phantom Models

  • Jang, Jung Eun;Lee, Yeon Sun;Jang, Woo Seok;Sung, Won Suk;Kim, Eun-Jung;Lee, Seung Deok;Kim, Kyung Ho;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • 제39권2호
    • /
    • pp.77-88
    • /
    • 2022
  • The purpose of this review was to identify research trends in acupuncture training systems and models and to analyze acupuncture training using phantom models. Articles on acupuncture training were retrieved from domestic and foreign electronic databases (PubMed, CNKI, CiNii, NDSL, KISS, RISS and KMBase). The search included studies conducted from January 1, 2010 to October 1, 2021. Acupuncture training was analyzed by categorization into acupoint location training and needling training. Acupuncture training was most frequently studied in China, acupoint location training was the most studied in 2012, and needling training was the most studied in 2013 and 2020. Among them, a silicone model with a sensor was used for training in acupoint location, and silicone and agarose gel were frequently used for needling training. Classifications of the phantom models for needling training by topic included phantom development, phantom-based education and evaluation system, phantom-based quantitative measurement, comparison of kinematic characteristics of hand motion between experts and beginners, and phantom models for acupoint location and needling training. Further research on the development of acupuncture practice training systems to improve practical skills is needed.

Research Trends of Acupuncture-Related Therapy on Microbiome in Musculoskeletal Disorders

  • Joo-Hee Kim
    • Journal of Acupuncture Research
    • /
    • 제40권2호
    • /
    • pp.129-134
    • /
    • 2023
  • In this review, we searched for clinical and experimental studies related to acupuncture-related therapy (ART) on the microbiome in musculoskeletal disorders (MSDs) through the electronic databases of MEDLINE via PubMed, EMBASE, and Oriental Medicine Advanced Searching Integrated System up to May 2023, without language restriction, and after the selection/exclusion process, the study design, target disease, intervention details, treatment period, outcomes, and study results were extracted. A total of 8 articles were selected. Two randomized controlled trials and 6 animal studies evaluated knee osteoarthritis, rheumatoid arthritis, spinal cord injury, ankylosing spondylitis, and osteoporosis. ART, including electroacupuncture, thread-embedding acupuncture, and moxibustion, affected microbiome modulation in MSDs. The results reveal that ART could be a potential treatment for regulating the microbiome in MSDs. However, further high-quality studies are needed.

Development of Electronic Acupuncture using Intelligence Technology

  • Hong, YouSik;Cho, Seongsoo;Shrestha, Bhanu;Kim, Young Roak
    • International journal of advanced smart convergence
    • /
    • 제3권2호
    • /
    • pp.10-13
    • /
    • 2014
  • In oriental medicine, the pulse beats are important signals that may let us know the conditions of one's health and disease. In other words, doctors of oriental medicine can simply analyze pulse waves anywhere and anytime to treat patients without using high-priced medical appliances. However, they are largely subjective in interpreting the pulse rates and hence their reliability is far from being perfect. The current paper aims to solve this problem by using fuzzy inference rules in judging patients' health status and to develop a software kit of intelligent electronic needles.