• Title/Summary/Keyword: Electron-Beam

Search Result 2,222, Processing Time 0.03 seconds

Fabrication of 2D Bravais Nano Pattern and Growth of ZnO Nano Rods with Photonic Crystal Effect (2차원 Bravais Lattice를 가지는 나노 패턴 제조 및 광결정 효과를 가지는 ZnO 나노 기둥 성장)

  • Kim, Tae-Un;Moon, Jong-Ha;Kim, Seon-Hoon;Kim, Doo-Gun;Kim, Jin-Hyeok
    • Korean Journal of Materials Research
    • /
    • v.21 no.12
    • /
    • pp.697-702
    • /
    • 2011
  • Two-dimensional (2D) nano patterns including a two-dimensional Bravais lattice were fabricated by laser interference lithography using a two step exposure process. After the first exposure, the substrate itself was rotated by a certain angle, $90^{\circ}$ for a square or rectangular lattice, $75^{\circ}$ for an oblique lattice, and $60^{\circ}$ for a hexagonal lattice, and the $90^{\circ}$ and laser incident angle changed for rectangular and the $45^{\circ}$ and laser incident angle changed for a centered rectangular; we then carried out a second exposure process to form 2D bravais lattices. The band structure of five different 2D nano patterns was simulated by a beam propagation program. The presence of the band-gap effect was shown in an oblique and hexagonal structure. The oblique latticed ZnO nano-photonic crystal array had a pseudo-bandgap at a frequency of 0.337-0.375, 0.575-0.596 and 0.858-0.870. The hexagonal latticed ZnO nano-crystallite array had a pseudo-bandgap at a frequency of 0.335-0.384 and 0.585-0.645. The ZnO nano structure with an oblique and hexagonal structure was grown through the patterned opening window area by a hydrothermal method. The morphology of 2D nano patterns and ZnO nano structures were investigated by atomic force microscopy and scanning electron microscopy. The diameter of the opening window was approximately 250 nm. The height and width of ZnO nano-photonic crystals were 380 nm and 250 nm, respectively.

Optimization of Cultivation and Storage Conditions on Red Cabbage Seed Sprouts (적양배추 새싹채소의 발아 및 저장 조건 최적화)

  • Baek, Kyeong-Hwan;Jo, Doekjo;Yoon, Sung-Ran;Kim, Gui-Ran;Park, Ju-Hwan;Lee, Gee-Dong;Kim, Jeong-Sook;Kim, Yuri;Han, Bumsoo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • This study was carried out to find the optimal conditions for red cabbage seed sprouts in terms of their physicochemical and sensory qualities by electron-beam irradiation, cultivation and storage using the response surface methodology (RSM). Moisture content ($R^2$=0.9638) was affected by irradiation dose and cultivation time. Total phenolics content ($R^2$=0.9117) was mainly affected by irradiation dose, but carotenoid content ($R^2$=0.8338) was affected in the order of irradiation dose, cultivation time and storage time. Sensory properties were also affected by irradiation dose, and thus scores decreased as irradiation dose increased. The optimum conditions estimated by superimposing total phenolics content and overall acceptance were 2.2-3.8 kGy of the irradiation dose, 3.0-4.0 days of cultivation and 2.0-3.0 days of storage.

Isoflavone Contents, Antioxidative and Fibrinolytic Activities of Red Bean and Mung Bean (팥과 녹두의 이소플라빈 함량과 항산화 및 혈전용해 활성)

  • 오혜숙;김준호;이명희
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.263-270
    • /
    • 2003
  • This study was conducted to investigate the isoflavone (daidzein and genistein) contents, and the antioxidative and fibrinolytic activities of red and mung beans. Daidzein was not found in either the red or mung beans. The genistein contents of the red and mung beans were 40.7 and 27.8 mg/kg, respectively. Both samples had very high electron donating abilities and SOD-like activities. Fibrinolytic activities were not detected in the crude mung bean extract, but fibrinolytic substances were purified or activated under various pH conditions and with heat treatments. With heat treatment at 100 $^{\circ}C$ for 10 min, the specific activity was increased 4.61 fold. This study revealed that, although red and mung beans were poor in isoflavone, they could be good sources for functional products due to their strong antioxidative activities and heat- and acid-resistant proteolytic abilities.

Production Technology of Titanium by Kroll Process (Kroll법에 의한 타이타늄의 제조기술)

  • Sohn, Ho-Sang
    • Resources Recycling
    • /
    • v.29 no.4
    • /
    • pp.3-14
    • /
    • 2020
  • Titanium sponge is industrially produced by the Kroll process. In order to understand the importance of the emerging smelting and recycling process, it is necessary to review the conventional production process of titanium. Therefore this paper provides a general overview of the conventional titanium manufacturing system mainly by the Kroll process. The Kroll process can be divided into four sub-processes as follows: (1) Chlorination of raw TiO2 with coke, by the fluidized bed chlorination or molten salt chlorination (2) Magnesium reduction of TiCl4 and vacuum distillation of MgCl2 and Mg by reverse U-type or I-type with reduction-distillation integrated retorts (3) Electrolysis process of MgCl2 by monopolar cells or multipolar cells to electrolyze into chlorine gas and Mg. (4) Crushing and melting process in which sponge titanium is crushed and then melted in a vacuum arc furnace or an electron beam furnace Although the apparatus and procedures have improved over the past 80 years, the Kroll process is the costly and time-consuming batch operation for the reduction of TiCl4 and the separation of MgCl2.

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

Fabrication and Electromechanical Behaviors of a SWNT/PANi Composite Film Actuator (탄소나노튜브/도전성폴리머 복합재 엑츄에이터의 제조 및 특성실험)

  • Zhang, Shuai;Kim, Cheol
    • Composites Research
    • /
    • v.19 no.5
    • /
    • pp.7-11
    • /
    • 2006
  • The improved SWNTs/PANi composite actuator films applicable to an artificial muscle were fabricated successfully using a new process of manufacture that consists of 90% pure single-walled carbon nanotubes (SWNT) and chemical polymerization. PANi is electrically conducting polyaniline polymer. The conductivities of the composite SWNTs/PANi film-type actuators and the pure PANi films fabricated were measured as 56.15 S/cm and 17.38 S/cm, respectively, by the 4-prove method. The conductivity of the composite actuator is 3.2 times higher than the pure PANi film. The fabricated composite actuator showed higher conductivity than any other similar ones. The quality of samples was investigated by an electron scanning microscope (SEM). To measure the actuating strains, a specially designed beam balance apparatus was developed and strains of the composite actuators was measured by a laser displacement sensor subjected to electric currents. During the operation, the sample was soaked in the $NaNO_3$ solution and the sine-wave voltage in the range of $+1V{\sim}-1V$ was applied. The length of the composite actuator changed from $l_0=12.690$ mm to $l_1=12.733$ so that the change of length was l=0.043 mm and the strain was 0.34 %. This is a very high strain for this kind of a composite actuator. Other result reported by Tahhan showed 0.23 % strain, so that the present result is improved by 48%.

Manufacturing and testing of flat-type divertor mockup with advanced materials

  • Nanyu Mou;Xiyang Zhang;Qianqian Lin;Xianke Yang;Le Han;Lei Cao;Damao Yao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2139-2146
    • /
    • 2023
  • During reactor operation, the divertor must withstand unprecedented simultaneous high heat fluxes and high-energy neutron irradiation. The extremely severe service environment of the divertor imposes a huge challenge to the bonding quality of divertor joints, i.e., the joints must withstand thermal, mechanical and neutron loads, as well as cyclic mode of operation. In this paper, potassium-doped tungsten (KW) is selected as the plasma facing material (PFM), oxygen-free copper (OFC) as the interlayer, oxide dispersion strengthened copper (ODS-Cu) alloy as the heat sink material, and reduced activation ferritic/martensitic (RAFM) steel as the structural material. In this study, a vacuum brazing technology is proposed and optimized to bond Cu and ODS-Cu alloy with the silver-free brazing material CuSnTi. The most appropriate brazing parameters are a brazing temperature of 940 ℃ and a holding time of 15 min. High-quality bonding interfaces have been successfully obtained by vacuum brazing technology, and the average shear strength of the as-obtained KW/Cu and ODS-Cu alloy joints is ~268 MPa. And a fabrication route for manufacturing the flat-type divertor target based on brazing technology is set. For evaluating the reliability of the fabrication technologies under the reactor relevant condition, the high heat flux test at 20 MW/m2 for the as-manufactured flat-type KW/Cu/ODS-Cu/RAFM mockup is carried out by using the Electron-beam Material testing Scenario (EMS-60) with water cooling. This paper reports the improved vacuum brazing technology to connect Cu to ODS-Cu alloy and summarizes the production route, high heat flux (HHF) test, the pre and post non-destructive examination, and the surface results of the flat-type KW/Cu/ODS-Cu/RAFM mockup after the HHF test. The test results demonstrate that the mockup manufactured according to the fabrication route still have structural and interfacial integrity under cyclic high heat loads.

Heterostructures of SnO2-Decorated Cr2O3 Nanorods for Highly Sensitive H2S Detection (고감도 H2S 감지를 위한 SnO2 장식된 Cr2O3 nanorods 이종구조)

  • Jae Han Chung;Yun-Haeng Cho;Junho Hwang;Su hyeong Lee;Seunggi Lee;See-Hyung Park;Sungwoo Sohn;Donghwi Cho;Kwangjae Lee;Young-Seok Shim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.40-47
    • /
    • 2024
  • The creation of vertically aligned one-dimensional (1D) nanostructures through the decoration of n-type tin oxide (SnO2) on p-type chromium oxide (Cr2O3) constitutes an effective strategy for enhancing gas sensing performance. These heterostructures are deposited in multiple stages using a glancing angle deposition technique with an electron beam evaporator, resulting in a reduction in the surface porosity of the nanorods as SnO2 is incorporated. In comparison to Cr2O3 films, the bare Cr2O3 nanorods exhibits a response 3.3 times greater to 50 ppm H2S at 300℃, while the SnO2-decorated Cr2O3 nanorods demonstrate an eleven-fold increase in response. Furthermore, when subjected to various gases (CH4, H2S, CO2, H2), a notable selectivity toward H2S is observed. This study paves the way for the development of p-type semiconductor sensors with heightened selectivity and sensitivity towards H2S, thus advancing the prospects of gas sensor technology.

Consideration about Ozone Generation in the Treatment Room While Treating a Patient (방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰)

  • Kwak, Yong-Kuk;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.75-82
    • /
    • 2009
  • Purpose: Measure the ozone level in the treatment room while treating a patient so want to know the degree of contamination caused by ozone occurrence. Materials and Methods: Use the linear accelerator (Clinac 21EX, Varian, USA) with the ozone meter (series-200, aeroQual, New Zealand) and water phantom (Wellhofer, IBA, Germany) is irradiated the radiation so that measured the ozone generation level according to MU, dose-rate, SSD, field size, energy, delay time and put the ozone meter in the treatment room actually while treating a patient so measured the daily ozone level variation. Results: While irradiating the radiation, degree of ozone contamination wasn't affected by the energy but mostly in case of electron beam, ozone level was higher than photon beam. The higher dose-rate (0.016~0.025 ppm/hr), the farther SSD (0.018~0.030 ppm/hr), the wider field sizes (0.016~0.025 ppm/hr), the more MU (0.018~0.046 ppm/hr), it occurred high ozone level. Ozone decrement according to delay time changed the background level (0.016 ppm/hr) after elapsed time of 10 minutes from irradiating radiation. And daily ozone occurrence level in the treatment room was below ozone standard level 0.1 ppm/hr (average:0.06 ppm/8 hr) but it could confirm that ozone generation level was included the level (max:0.038 ppm/hr) above 0.02 ppm/hr which patient could perceive. Conclusion: Through ozone level according to variation of certain conditions, actually in the treatment room ozone generation level didn't damaged to patients or workers. Commonly peoples think that ozone was harmful gas but it thought that small amount of ozone generation level while treating a patient was beneficial in the treatment room through air purge action of pathogenic germ or virus sterilization.

  • PDF