• 제목/요약/키워드: Electrokinetic effect

검색결과 59건 처리시간 0.022초

중금속으로 오염된 카올린의 Electrokinetic 처리와 효율증강에 관한 연구 (A Experimental Study of Electrokinetics and Enhanced Process with Kaolin Specimen Contaminated with Heavy metals)

  • 정방미;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.241-246
    • /
    • 1999
  • In this research, electrokinetic remediation test was experimented with contaminated kaoline specimen at below, above the cation-exchange capacity of the mineral. The changes of the flow in electro-osmosis with open electrodes and current were presented, and lead removal results were evaluated through the extraction test. As a result, it was showed that removal efficiency was 20-30%, 67-87% In the anode As lead transport continues, the lead precipitation within a narrow zone very close to the cathode can go significantly high. This high lead precipitation near the cathode could block the flow path, decrease the conductivity, and thus the electroosmotic flow. The net effect will cause a decrease in the efficiency of electrokinetic processing. Therefore, in this study, citric acid and surfactant solution was used at the cathode as enhancement techniques.

  • PDF

Electrokinetic 기법에 의한 광산퇴적토내 Cd과 Pb의 제거 특성에 관한 연구 (The Study of Cd and Pb Characteristics on Electrokinetic Remediation of Mine Deposit)

  • 윤삼석;신현무;이창언
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.61-64
    • /
    • 2001
  • In the remediation of contaminated soil by electrokinetic process, transport characteristics of contaminants are major factors. Pb is highly fixed to entire soil and not moved readily. High concentration of Cd was analyzed in the cathodic section but anodic section's concentration was lower than initial concentration. Although the Cd had high treatment effect, 50% of total mass was concentrated in cathodic section and was not flowed out readily. Most of transported Cd may be adsorbed in the cathodic side soil due to increased pH at adjacent to catholyte.

  • PDF

Electrokinetic-Fenton 공정에 의한 Phenanthrene으로 오염된 카올린의 정화 (The remediation of contaminated kaolinite by phenanthrene using Electrokinetic-Fenton process)

  • 김정환;김익현;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.593-596
    • /
    • 2002
  • This study examined the feasibility of Electrokinetic-Fenton process for remediation of contaminated kaolinite by phenanthrene. The test using 7% H$_2$O$_2$as anode purging solution indicated the higher electrical current and electroosmotic flow than the test using 3.5% H$_2$O$_2$. And distribution in the soil of H$_2$O$_2$concentration showed the higher value of the former than the latter. Furthermore, the test using 7% H$_2$O$_2$and 0.01N H$_2$SO$_4$was the highest electrical current and electroosmotic flow and H$_2$O$_2$was effectively introduced to the cathode region. As it turned out, the treatment effect of phenanthrene was improved in compare with the other tests.

  • PDF

Electrokinetic cell을 이용한 해성점토지반의 개량효과 연구 (Electrokinetic Strengthening of Soft Marine Clays in E/K Cell)

  • 이승원;이영남
    • 한국지반공학회지:지반
    • /
    • 제14권4호
    • /
    • pp.77-90
    • /
    • 1998
  • 본 연구에서는 /K cell(286\times254\times119mm)$을 이용하여 해성점토 지반에서의 electrokinetic 공법에 의한 지반개량효과를 비교 연구하였다. 남해안 해성점토에 대해서 순수 재하시험과 저전압을 이용한 전기삼투시험, 그리고 고전압을 이용한 전기영동시험을 실시한 결과, 저전압 전기삼투에 의한 지반개량 효과가 제일 컸으며, 고전압 전기영동에 의한 지반개량효과는 거의 없는 것으로 나타났다. 또한 전기삼투시험에서는 전류가동시간과 전류밀도가 클수록, 즉 전력소모량이 많을수록 지반 개량효과가 크게 나타났다.

  • PDF

산 완충능력과 토양 성분이 동전기-펜톤 공정에 의한 phenanthrene 오염토양 정화에 미치는 영향 (Effect of Acid Buffering Capacity and Soil Component Remediation of Soil Contaminated with Phenanthrene using Electrokinetic-Fenton Process)

  • 김정환;나소정;박주양;변영덕
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권1호
    • /
    • pp.129-136
    • /
    • 2013
  • This research was conducted to investigate effects of acid buffering capacity and soil component in treatment of phenanthrene using electrokinetic-Fenton process. In Hadong clay of high acid buffering and low iron oxide content, it was difficult to oxidize phenanthrene due to shortage of iron catalyst and scavenger effect of carbonate minerals. The desorbed phenanthrene conductive to Fenton oxidation was transported toward cathode by electroosmotic flow. However, in Youngdong illitic clay, oxidation of phenanthrene near anode readily occurred compared to Hadong clay due to high iron content and low acid buffering capacity.

Dispersant-Binder Interactions in Aqueous Silicon Nitride Suspensions

  • Paik, Ungyu
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 제11차 KACG 학술발표회 Crystalline Particle Symposium (CPS)
    • /
    • pp.129-153
    • /
    • 1996
  • In aqueous slurry processing of silicon nitride, the interaction of dispersant and binder on the surface of particles was studied to identify the effect of these additives on ceramic powder processing. Polymethacrylic acid (PMAA) and polyvinyl alcohol (PVA) were used as dispersant and binder, respectively. the adsorption isotherms of PMAA and PVA for the silicon nitride suspension were determined, while the adsorption of PMAA was differentiated in the mixed additive system by ultraviolet spectroscopy. These experiments were done in order to investigate the effect of these organic additives on the physicochemical properties of silicon nitride suspensions. The electrokinetic behavior of silicon nitride was subsequently measured by electrokinetic sonic amplitude (ESA). As PMAA adsorbed onto silicon nitride, the isoelectric point (pHicp) shifted from pH=6.7 to acidic pH, depending on the surface coverage of PMAA. However, adsorption of PVA did not change the pHicp of suspensions, but did decrease the surface potential of silicon nitride moderately. The rheological behavior of silicon nitride suspensions was measured to assess the stability of particles in aqueous media, and was correlated with the electrokinetic behavior and adsorption isotherm data for silicon nitride.

  • PDF

공간 제약 효과에 따른 전기와류 불안정성의 동역학 전이 (Dynamics Transition of Electroconvective Instability Depending on Confinement Effect)

  • 이승하;현철헌;이효민
    • Korean Chemical Engineering Research
    • /
    • 제59권4호
    • /
    • pp.626-631
    • /
    • 2021
  • 전기투석장치, 전기화학 전지, 미세유체역학 분석 장치 등에서 사용하는 이온 교환 막 근처의 대표적인 비선형 전기동역학 현상은 전기와류 불안정성이다. 전기투석 장치에서 전기와류 불안정성은 물질 전달 속도 증폭을 통해 물질 전달에 대한 이점을 제공한다. 그러나 전기화학 전지나 미세유체역학 장치에서 발생하는 불안정성은 원치 않는 물질 전달 기작을 유발시킨다. 본 연구에서는 전기와류 불안정성의 제어하기 위해, 인가 전압과 공간 제약 효과의 전기와류 불안정성에 대한 영향을 연구하였다. 그 결과, 인가 전압과 공간 제약의 정도에 따라 불안정성의 동역학이 안정 영역 - 고정 영역 - 혼돈 영역 순으로 전이됨을 밝혀내었다. 더불어, 동역학 전이에 대한 안정성 곡선을 수치적으로 결정하였다. 결론적으로, 공간 제약 효과는 전기동역학적 혼돈을 제어할 수 있는 효과적인 기작으로 활용 가능할 것이다.

Cu, Pb, 및 Cd로 오염된 토양의 동전기적 방법에 의한 제거에 있어 중금속 종이 미치는 영향 (Effect of Heavy Metal Species on the Removal of Cu, Pb, and Cd Contaminated Soils Using Electrokinetic Process)

  • 신현무;윤삼석
    • 한국환경과학회지
    • /
    • 제13권1호
    • /
    • pp.61-68
    • /
    • 2004
  • Three kinds of toxic heavy metals, such as lead, copper, and cadmium, existing abundantly in contaminated soils were selected to investigate pH change, electroosmotic flow, and the removal rate in the application of electrokinetic process. In the change of pHs, they reached to about 12 and 2 at each cathodic and anodic region, respectively, and maintained for reaction being proceeded. Electroosmotic flow rates were not influenced by the kind of metal species but by electropotential gradient. On the soils contaminated by each metal, the removal rate of Cd was the fastest among three as in the order of Cd>Pb>Cu. While on the soils contaminated by mixed metal species, Cu was the fastest. Metal species transported by electrokinetic processes were distributed in between 0.9 and 1.0 of normalized region. In the case of soils contaminated by one kind of metal. the relative concentrations of Pb and Cd estimated in between normalized region 0.9 and 1.0 were 5.2 and 5.7, respectively.

Effect of Electrolyte Concentration on Surfactant-Enhanced Electrokinetic Removal of Phenanthrene

  • 이유진;박지연;김상준;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.346-349
    • /
    • 2004
  • Surfactant-enhanced electrokinetic (EK) process was investigated to remove polycyclic aromatic hydrocarbons (PAHs) from low-permeable soils. Phenanthrene and kaolinite were selected as a representative PAH and a model soil, respectively. A nonionic surfactant Tergitol 15-S-12 was applied to improve the solubility of phenanthrene and sodium chloride was used as an electrolyte at the various concentrations from 0.001 to 0.1M. The addition of electrolyte affected both the removal efficiency and operation cost. When electrolyte was introduced, the electrical potential gradient became low and thus power consumption was reduced. However, as electrolyte concentration increased, the electroosmotic flow also decreased, so the removal efficiency of contaminant decreased. Therefore, the removal efficiency and power consumption should be considered simultaneously to determine the iptimum surfactant concentration, so a relatively lower concentration of electrolyte than certain value is desired.

  • PDF

Electrokinetic-Fenton 기법에 의한 phenanthrene으로 오염된 토양의 처리

  • 김정환;김강호;한상재;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.51-54
    • /
    • 2001
  • This research was carried out to evaluate feasibility of using an Electrokinetic-Fenton(EK-Fenton) technique to treat hydrophobic organic pollutant(phenanthrene) from soils. Experiment examined the effect by introducing a continuous flow of a 3.5% hydrogen peroxide solution at the anode. An electric gradient of 1V/cm was applied to enhance the saturated flow in the soil cell for a period of 11 days. After 11 days or 1 pore volume, overall concentration of residual phenanthrene in the soil cell was 11% and residual phenanathrene concentration in the soil was found to increase with toward the cathode. This results indicated that Fenton-like reaction catalyzed by mineral surface was effective in oxidizing phenanthrene. This results also showed that hydrogen peroxide was effectively transported into the soil by electroosmotic flow as well as by diffusion.

  • PDF