• 제목/요약/키워드: Electrode size

검색결과 801건 처리시간 0.029초

전극형성과 태양전지 모듈 일체화 기술 개발에 적용되는 태양전지 전극 설계 기술 (Electrode Design for Electrode Formation and PV Module Integration Development)

  • 박진주;전영우;장민규;김민제;임동건
    • Current Photovoltaic Research
    • /
    • 제9권4호
    • /
    • pp.123-127
    • /
    • 2021
  • This study was on electrode design for the realization of a solar cell that combines electrode formation and module integration process to overcome printing limitations. We used the passivated emitter rear contact (PERC) solar cell. Wafer size was 156.75 mm ×156.75 mm. The fabricated cell results showed that the open-circuit voltage of 649 mV, short-circuit current density of 36.15 mA/cm2, fill factor of 68.5%, and efficiency of 16.06% with electrode conditions the 24BBs with the width 190 ㎛ and 90FBs with the width 45 ㎛. For improving efficiency, the characteristics of the solar cell were checked according to the change in the number of BBs and FBs and the change in line fine width. It is confirmed that the efficiency of the solar cell will be improved by increasing the number of FBs from 90 to 120, and increasing the line width of the FBs by about 10 ㎛ compared to the manufacturing solar cells.

동잡음 저감을 위한 심전도 전극 특성에 대한 연구 (Study on Characteristics of ECG Electrodes for Motion Artifact Reduction)

  • 강영환;박재순;조범기;최상동;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

Electrochemical Detection of $17{\beta}-estradiol$ by using DNA Aptamer Immobilized Nanowell Gold Electrodes

  • Kim, Yeon-Seok;Jung, Ho-Sup;Lee, Hea-Yeon;Kawai, Tomoji;Gu, Man-Bock
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.88-92
    • /
    • 2005
  • Aptamer is the single-stranded oligonucleotide which binds to various target molecules such as proteins, peptides, lipids and small organic molecules with high affinity and specificity. DNA aptamers specific for the $17{\beta}-estradiol$ were selected by SELEX (Systematic Evolution of Ligands by EXponential enrichment) process from a random DNA library. These DNA aptamers have a high affinity to $17{\beta}-estradiol$ as an endocrine disrupting chemical. Nanowell and $200{\mu}m$ gold electrode were used as substrate for DNA aptamer immobilization and electrochemical analysis. Especially, nanowell gold electrode was fabricated by e-beam lithography. The size of single nanowell is 130nm and 40,000 nanowells were deposited on one gold electrode. The immobilization method was based on the interaction between the biotinylated aptamer and streptavidin deposited on gold electrode previously. Immobilization procedure was optimized by surface plasma resonance (SPR) and electrochemical analysis. After the immobilization of DNA aptamer on streptavidin modified gold electrode, $17{\beta}-estradiol$ solution was treated on aptamer immobilized gold electrode. The current of gold electrode was decreased by the binding of $17{\beta}-estradiol$ to DNA aptamer immobilized on gold electrode. However, in negative control experiments of 1-aminoanthraquinone and 2-methoxynaphthalene, the current was rarely decreased. And more sensitive data was obtained from nanowell gold electrode comparing with $200{\mu}m$ gold electrode.

  • PDF

Determination of the voltage distribution in the external electrode fluorescent lamps for the backlight unit of large-size LCD

  • Choi, Jae-Young;Kim, Young-Youb;Ko, Jae-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1374-1377
    • /
    • 2006
  • The voltage distribution of an external electrode fluorescent lamp(EEFL) having a gas pressure of 50 torr and a gas composition of Ne:Ar with a ratio of 90:10 has been estimated by varying the distance between the two external electrodes and monitoring the change of the lamp voltage. The estimated voltage gradient, which represents the electric field in the positive column of the EEFL, was very sensitive to the electrode area of EEFL and was in the range of $13\;{\sim}\;27\;V/cm$ at the electrode length of $15\;{\sim}\;31\;mm$. Changing the lamp current in the range $3\;{\sim}\;5\;mA$ did not make noticeable difference in the electric field of the positive column. Theses results may serve as basic data for the optimization of electric and optic characteristics of EEFL.

  • PDF

전기집전기 방전극 프레임 최적 설계 (Optimal Design of Discharge Electrode Frame in Electrostatic Precipitator)

  • 이후광;최재승;황석환;조창호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.626-629
    • /
    • 1997
  • In this study, position optimization of insulation rods and suspension rods in discharge electrode frame of electrostatic precipitator(EP) is performed using finite element analysis(FEA). The object of the optimization is to minimize the difference of altitudes in unevenly sagged horizontal structure and to regulate the size of materials within the allowable stress bounds. Uppermost horizontal channel of discharge electrode frame is highly stressed and uniformity of lowest horizontal angle depends on the position of rods. Ten types of frame are analyzed and one recommended model is presented.

  • PDF

A Novel EST with Trench Electrode to Immunize Snab-back Effect and to Obtain High Blocking Voltage

  • Kang, Ey-Goo;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권3호
    • /
    • pp.33-37
    • /
    • 2001
  • A vertical trench electrode type EST has been proposed in this paper. The proposed device considerably improves snapback which leads to a lot of problems of device applications. In this paper, the vertical dual gate Emitter Switched Thyristor (EST) with trench electrode has been proposed for improving snab-back effect. It is observed that the forward blocking voltage of the proposed device is 745V. The conventional EST of the same size were no more than 633V. Because the proposed device was constructed of trench-type electrodes, the electric field moved toward trench-oxide layer, and the punch through breakdown of the proposed EST is occurred at latest.

  • PDF

GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향 (Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability)

  • 이방욱;구자윤;김민규;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

PERFORMANCE OF MULTILAYER CERAMIC ACTUATOR BY CONSIDERING THE SHAPE EFFECT

  • 위상봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.594-597
    • /
    • 2003
  • In the present study, the piezoelectricity and polarization of multilayer ceramic actuator, being designed to stack PMN-PZ-PT ceramic layers and Ag-Pd electrode layers alternatively, were investigated under a consideration of geometric factor, the volume ratio of the ceramic to the electrode layers. The actuators were fabricated by tape casting of 0.2Pb(Mg1/3Nb2/3)O3-0.38PbZrO3-0.42PbTiO3 followed by lamination and burnout & co-firing processes. The actuators of 10 10 0.62 nm3 in size were formed in a way that 60 200 m thick ceramics were stacked alternatively with 5 m thick electrode layer. Increases in polarization and electric field-induced displacement with thickness of the ceramic layer were attributed to change of 90o/180o domain ratio, which was affected by interlayer internal stress. The piezoelectricity and actuation behaviors were found to depend upon the volume ratio (or thickness ratio) of ceramic to electrode layers.

  • PDF

하전입자의 분포에 따른 Electrowetting display의 오일의 움직임 (Oil Movement Control by Charge Density Control in the Electrowetting Display)

  • 김태현;김연식;;정은;한윤봉;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.495-496
    • /
    • 2006
  • Electrowetting phenomenon is applied in the various field of technology. One of that is electrowetting display as a paper like electronic paper. Fast response and easy to express a color is goodness. In spite of that, the oil movement of the electrowetting display is irregular. So it doesn't look like uniform. Because of above reason, electrowetting display using patterned electrode is made and the characteristic of oil movement is observed. Electrode and polymer wall is patterned by photo-lithography. We analyze the oil movement according to the variation of size and the position of etched electrode area.

  • PDF

절삭유의 필터링 시스템이 플라즈마 에칭 전극의 표면 품질에 미치는 영향 (Effects of Filtering System of Cutting Fluid on the Surface Quality of Plasma Etching Electrode)

  • 이은영;김문기
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.46-50
    • /
    • 2018
  • The purpose of this study is to analyze effects of filtering system of cutting fluid which is used for machining silicon electrode. For the research, different sizes of filter clothes are applied to check grain size of sludge of cutting fluid. Surface roughness of machined workpiece, depth of damage inside of silicon electrode, and suspended solids of cutting fluid are experimented and analyzed. From these experiments, it is verified that filtering system of cutting fluid is very important factor for machining. Results of this study can affect various benefits to the semiconductor industry for better productivity and better atmospheric pollution in workplace.