• 제목/요약/키워드: Electrochemical Impedance

검색결과 899건 처리시간 0.024초

Evaluation of the Inhibitive Performance of Cyperus Conglomeratus Leaves Extract as a Green Corrosion Inhibitor on Mild Steel XC70 in Acid Medium

  • Belkis, Guessoum;Abdelkader, Hadj Seyd;Oumelkheir, Rahim
    • Corrosion Science and Technology
    • /
    • 제21권3호
    • /
    • pp.171-183
    • /
    • 2022
  • The performance and inhibitory action of the aqueous extract of Cyperus Conglomeratus's leaves against corrosion of XC70 steel in a 1M HCl acid medium are studied by the determination of the weight loss, the potentiodynamic polarization curves analysis, and electrochemical impedance measurements (electrochemical techniques). The corrosion inhibitory efficiency of XC70 steel increases with the increasing concentration of the green inhibitor, however, the corrosion rate of the steel decreases. Weight loss measurements show that the maximum percentage corrosion inhibition efficiency is approximately 61.86%, while the analysis of the mixed character polarization curves shows that the inhibitor could achieve an inhibition efficiency of 86.96%. The electrochemical impedance study confirmed that the value of the charge transfer resistance (Rct) increases and the value of the double layer capacity (Cdl) decreases with increasing concentration of the aqueous extract of Cyperus Conglomeratus's leaves, thus increasing the inhibition efficiency. The study showed that this aqueous extract acts by adsorption on the metal surface; this adsorption follows the Langmuir isotherm. This research work showed that Cyperus Conglomeratus leaves extract acts as an effective and eco-friendly inhibitor on mild steel in an acid medium.

가정용 연료전지 스택의 EIS 평가 기법 개발 (Development of EIS Evaluation Method about PEMFC 1kW STACK)

  • 박찬엄;한운기;정진수;고원식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.100.1-100.1
    • /
    • 2011
  • Electrochemical impedance spectroscopy(EIS) are using widely as a useful technique mainly in the field of electrochemical for the analysis of electrode reactions or characteristics of the composites. The response analysis of the systems technique provides comprehensive informations about the characteristic and structure of complex and internal reaction. The EIS is the method to measure impedance of the measurement target classified by the frequency, it select the equivalent impedance model to give same response from the result and it calculate the parameter. Therefore, the chemical reaction inside the fuel cell is to modeling to electrical impedance. And as repeating the same experiment in each of the operating point, we can get each different parameter. As a result, we can establish the equivalent impedance model in each operating point. Therefore, if we use these models, we can evaluate the fuel cell without the internal design parameter of the fuel cell as required in existing modeling. The EIS is used typically technique for distinguish status of fuel cell called SOH(State Of Health). When the fuel cell is degradation, Efficiency and health of the fuel cell is reduced because internal impedance is increase. As usage of these principles, we can evaluate state of fuel cell through the impedance analysis of fuel cells. In this study, we are presents EIS distinction system and algorithm for residential fuel cell systems. At the time of the fuel cell installation in the fields, the EIS system and proposed algorithm will be able to apply as technique for efficiency and performance evaluation about fuel cell system.

  • PDF

EIS를 이용한 시멘트 모르타르에 매입된 철근의 부식거동에 관한 실험적 연구 (An Experimental Study on the Corrosion Behavior of Rebar in Cement Mortar by Using EIS Method)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.145-146
    • /
    • 2016
  • In this study, Corrosion behavior in mortar was observed by the passage of time by using EIS method. As a result of EIS experiment, equivalent circuit and changes of Impedance parameter could be observed. In addition, it was confirmed that impedance of rebar in mortar and corrosion rate according to the amount of NaCl were different.

  • PDF

Electrochemical Behavior of AZ31 Mg Alloy in Neutral Aqueous Solutions Containing Various Anions

  • Duyoung Kwon;Hien Van Pham;Pungkeun Song;Sungmo Moon
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.311-319
    • /
    • 2023
  • This work was performed to characterize the electrochemical behavior of AZ31 Mg alloy in neutral aqueous solutions where Cl-, SO42-, PO43-, and F- ions were present and pH was adjusted to 6 to exclude the contribution of H+ and OH- ions. Open-circuit potential (OCP) transient, electrochemical impedance spectroscopy (EIS) and potnetiodynamic polarization curves were employed. The OCP value appeared to decrease in the order of F- > Cl- > SO42- > PO43- ions while corrosion current density increased in the same order. Electrochemical impedance spectroscopy (EIS) data showed two capacitive arcs in all the solutions and one more inductive arc appeared in PO43--containing solution. By fitting of two capacitive arcs, capacitance of dense film (Cdf), resistance of porous film (Rpf) and double layer capacitance (Cdl) and charge transfer resistance (Rct) beneath the porous films were obtained. A simplified model in which various thicknesses and coverages of dense and porous films are assumed to be present on the AZ31 Mg alloy surface, is suggested to explain the effects of four different anions on the electrochemical behavior of AZ31 Mg alloy.

Electroactive Conjugated Polymer / Magnetic Functional Reduced Graphene Oxide for Highly Capacitive Pseudocapacitors: Electrosynthesis, Physioelectrochemical and DFT Investigation

  • Ehsani, A.;Safari, R.;Yazdanpanah, H.;Kowsari, E.;Shiri, H. Mohammad
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권4호
    • /
    • pp.301-307
    • /
    • 2018
  • The current study fabricated magnetic functional reduced graphene oxide (MFRGO) by relying on ${FeCl_4}^-$ magnetic anion confined to cationic 1-methyl imidazolium. Furthermore, for improving the electrochemical performance of conductive polymer, hybrid poly ortho aminophenol (POAP)/ MFRGO films have then been fabricated by POAP electropolymerization in the presence of MFRGO nanorods as active electrodes for electrochemical supercapacitors. Surface and electrochemical analyses have been used for characterization of MFRGO and POAP/ MFRGO composite films. Different electrochemical methods including galvanostatic charge discharge experiments, cyclic voltammetry and electrochemical impedance spectroscopy have been applied to study the system performance. Prepared composite film exhibited a significantly high specific capacity, high rate capability and excellent cycling stability (capacitance retention of ~91% even after 1000 cycles). These results suggest that electrosynthesized composite films are a promising electrode material for energy storage applications in high-performance pseudocapacitors.

건습환경중 순 Mg박막의 EIS부식 모니터링 특성 관찰 (Properties Investigation of Corrosion Monitoring for Pure Mg Thin Films under Wet-Dry Cyclic Conditions by Using Electrochemical Impedance Spectroscopy Method)

  • 배일용;이경희;김기준;문경만;이명훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.192-193
    • /
    • 2005
  • Magnesium thin films were prepared on cold-rolled steel substrates by RF(Radio Frequency) magnetron sputtering technique.$^{1)}$ The crystal orientation and monitoring of the deposited films were investigated by using XRD(X-ray Diffraction) and EIS(Electrochemical Impedance Spectroscopy), respectively. The corrosion rates of Mg thin films deposited with different argon gas pressure and substrate bias voltage were monitored by AC impedance method under a cyclic wet-dry condition, which was conducted by exposure to alternate conditions of 1h immersion in 3%NaCl solution and 5h drying at 60% RH and 25$^{\circ}C$. The result of corrosion rate of Mg thin films deposited at various Ar gas pressures and substrate bias voltage under wet-dry cyclic exposure in chloride-containing solutions was showed the following conclusions. At the region I during the onset of the wet cycle, corrosion rate showed relatively low value. The increase in the Corrosion rate of region II is due to the increase in the chloride concentration. Corrosion rate of region III during the onset of the cycle zero and salt crystals remain on the metal surface.$^{2)}$

  • PDF

$TiO_2$ 두께에 따른 염료감응형 태양전지의 전기화학적 임피던스 분석 (Electrochemical Impedance Spectroscopy Analysis on the Dye-sensitized Solar Cell with Different $TiO_2$ thicknesses)

  • 김희제;이정기;서현웅;손민규;김진경;프라바카르;신인영
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2425-2430
    • /
    • 2009
  • Dye-sensitized solar cell(DSC) is composed of a dye-adsorbed nanoporous $TiO_2$ layer on fluorine-doped tin oxide(FTO) glass substrate, electrolyte, and platinium doped counter electrode. Among these, a dye-absorbed nanoporous $TiO_2$ layer plays an important role in the performance of the DSC because the injected electrons from excited dye molecules move through this layer. And the condition of $TiO_2$ layer such as the morphology and thickness affects on the electron movement. Therefore, the performances and the efficiency of DSC change as the thickness of $TiO_2$ layer is different. Electrochemical Impedance Spectroscopy(EIS) is the powerful analysis method to study the kinetics of electrochemical and photoelectrochemical processes occurring in the DSC especially the injected electron movements. So we analyzed the DSCs with different $TiO_2$ thicknesses by using EIS to understand the influence of the $TiO_2$ thickness to the performance of the DSC clearly. Finally, we got the EIS analysis on the DSC with different $TiO_2$ thickness from the internal resistance of the DSC, the electron life time and the amount of dye molecules.

Electrochemical Noise Analysis on the General Corrosion of Mild steel in Hydrochloric Acid Solution

  • Seo, Do-Soo;Lee, Kwang-Hak;Kim, Heung-Sik
    • Corrosion Science and Technology
    • /
    • 제7권6호
    • /
    • pp.319-323
    • /
    • 2008
  • The polarization resistance of mild steel in 0.5M hydrochloric acid has been evaluated by using impedance (Z) and linear polarization (LPR) techniques and compared to the noise resistance obtained from electrochemical noise data. The degree of localization of this general corrosion has also been discussed by evaluating localization index and power spectral density. Polarization resistance obtained by LPR technique ($28\Omega$) was higher than that obtained by impedance technique ($15\Omega$). Noise resistance ($11\Omega$) was much lower than polarization resistance measured by both of above techniques. Higher polarization resistance obtained by LPR technique is generally caused by passivation effect in the presence of scales or deposits which can introduce an increased resistance as can low conductivity electrolytes. The reason why noise resistance is lower than polarization resistance is the effect of background noise detected by using three platinum electrodes cell in 0.5M hydrochloric acid. Slope($-\beta$) of power spectral density (PSD) obtained from analysis of noise data ($-\beta$ = 3.3) was much higher than 2 which indicates mild steel corroded uniformly. Localization index (LI) calculated from statistical analysis (LI=0.08) is much lower than 1 which indicates that mild steel did not corroded locally. However, LI value is still higher than $1x10^{-3}$ and this indicates that mild steel corroded locally in microscopic point of view.

전도성 고분자-리그닌 복합소재의 전기화학적 특성 분석 (The Electrochemical Characterization of Conducting Polymer-Lignin Composite)

  • 배준원
    • 공업화학
    • /
    • 제33권2호
    • /
    • pp.210-215
    • /
    • 2022
  • 표면의 전하 특성이 다른 두 가지 리그닌을 사용하여 이전 연구에서 제시된 간단한 방법인 용액상 화학적 중합을 이용하여 폴리피롤@리그닌(PPy@lignin) 및 폴리피롤@리그노설포네이트(PPy@lignosulfonate) 복합소재를 제조하였다. 폴리피롤은 두 가지 리그닌 표면에서 각각 성공적으로 중합되었으며, 얻어진 복합소재들은 주사전자현미경, 순환전압 전류법, 임피던스(impedance) 분석법 등을 이용하여 분석하였다. 이러한 결과들을 바탕으로, 리그닌의 종류가 달라도 복합재료들은 성공적으로 제조되는 것을 알 수 있었으며, 전기적 특성도 일정하게 유지되는 것으로 나타났다. 다만, 개별 리그닌의 표면 특성 차이로 나타나는 물성 차이가 존재함을 임피던스 분석으로 판단할 수 있었다. 나아가, 두 가지 복합소재들을 아가로즈(agarose) 젤(gel)에 투입하여 전도성 젤을 형성하고 이 젤들의 특성들을 역시 순환전압전류법으로 살펴보았으며, 전기전도도를 측정하여 제시하였다. 리그닌의 전기절연성에도 불구하고 전도성 젤이 전기전도도를 포함한 전기적 특성을 유지하는 것을 알 수 있었다. 이는 전도성 젤의 활용이 가능하다는 점을 의미한다.