• 제목/요약/키워드: Electrical response

검색결과 3,677건 처리시간 0.03초

돼지 분만 시기의 조절에 관하여 II. 자궁 평활근의 운동성에 대한 교감신경과 Adrenergic Agonist의 영향 (Control of Parturition Time on Pig II. Effect of Sympathetic Nerve and Adrenergic Agonist on Uterine Smooth Muscle Motility)

  • 심철수;이양성;임종옥
    • 한국동물위생학회지
    • /
    • 제17권3호
    • /
    • pp.255-263
    • /
    • 1994
  • To elucidate the action of the adrenergic nerve on the isolated uterine smooth muscle of the pig, effects of electrical transmural nerve stimulation and norepinephrine were investigated on the pretreatment of phentolamine ; non-selective ${\alpha}$-adrenoceptor blocker, propranolol ; ${\beta}$-adrenoceptor blocker and the yohimbine;${\alpha}_2$-selective adrenoceptor blocker from physiograph. 1. The relaxation response induced by norepinephrine was the concentration of $10^{-6}$ M at first and maximum response was concentration of $10^{-4}$M. 2. The relaxation response induced by norepinephrine was not effected by the pretreatment with non-selective $\alpha$-adrenoceptor blocker, phentolanune ($10^{-6}$ M) but was completely blocked by the pretreatment with ${\beta}$-adrenoceptor blocker, propranolol($10^{-6}$ M). 3. The contractile response induced by electrical transmural nerve stimulation(20V, 10Hz, 0.5msec, 20sec ) was inhibited by the pretreatment with non-selective ${\alpha}$-adrenoceptor blocker, phentolamine($10^{-6}$ M) but was not inhibited and rather increased by the pretreatment ${\beta}$-adrenoceptor blocker, propranolol($10^{-6}$ M), and was not approximately effected by the pretreatment with ${\alpha}_2$-adrenoceptor blocker, yohimbine($10^{-6}$ M). These finding suggest that it was excitatory action by ${\alpha}_1$-adrenergic nerve and inhibitory action by ${\alpha}_2$-adrenergic, ${\beta}$-adrenergic nerve on uterine smooth muscle of the pig.

  • PDF

돼지 분만 시기의 조절에 관하여 I. 자궁 평활근의 운동성에 대한 부교감 신경과 Cholinergic Agonist의 영향 (Control of Parturition Time on Pig I. Effect of Parasympathetic Nerve and Cholinergic Agonist on Uterine Smooth Muscle Motility)

  • 박상은;황보원;변유성;조광제
    • 한국동물위생학회지
    • /
    • 제17권3호
    • /
    • pp.247-254
    • /
    • 1994
  • To elucidate the action of the cholinergic nerve on the isolated uterine smooth muscle of the pig, effects of electrical transmural nerve stimulation and acetylcholine were investigated on the pretreatment of the physostigmine ; cholinestrase inhibitor and atropine ; cholinergic receptor blocker from physiograph. 1. The contractile response induced by acetylcholine was responsed in the concentration of 10^{-8}$ M at first and the maximum contractility was concentration of $10^{-6}$ M. 2. The contractile response induced by electrical transmural nerve stimulation(20 V, 0.5 Msec, 20 sec) was the frequency(2-64 Hz) -dependent manner. 3. The contractile response induced by acetylcholine was completely blocked by the pretreatment with cholinergic receptor blocker, atropine and was increased by the pretrement of cholinestrase inhibitor, physostigmine. 4. The contractile response induced by electrical transmural nerve stimulation was completely blocked by the pretreatment with cholinergic receptor blocker, atropine, and was increased by the pretretment of cholinestrase inhibitor, physostigmine. These findings suggest that it was powerful excitatory action by cholinergic nerve on uterine smooth muscle of the pig.

  • PDF

Percolation threshold and piezoresistive response of multi-wall carbon nanotube/cement composites

  • Nam, I.W.;Souri, H.;Lee, H.K.
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.217-231
    • /
    • 2016
  • The present work aims to develop piezoresistive sensors of excellent piezoresistive response attributable to change in nanoscale structures of multi-wall carbon nanotube (MWNT) embedded in cement. MWNT was distributed in a cement matrix by means of polymer wrapping method in tandem with the ultrasonication process. DC conductivity of the prepared samples exhibited the electrical percolation behavior and therefore the dispersion method adopted in this study was deemed effective. The integrity of piezoresistive response of the sensors was assessed in terms of stability, the maximum electrical resistance change rate, and sensitivity. A composite sensor with MWNT 0.2 wt.% showed the lowest stability and sensitivity, while the maximum electrical resistance change rate exhibited by this sample was the highest (96 %) among others and even higher than those found in the literature. This observation was presumably attributed by the percolation threshold and the tunneling effect. As a result of the MWNT content (0.2 wt.%) of the sensor being near the percolation threshold (0.25 wt.%), MWNTs were close to each other to trigger tunneling in response of external loading. The sensor with MWNT 0.2 wt.% was able to maintain the repeatable sensing capability while sustaining a vehicular loading on road, demonstrating the feasibility in traffic flow sensing application.

Control Strategy Based on Equivalent Fundamental and Odd Harmonic Resonators for Single-Phase DVRs

  • Teng, Guofei;Xiao, Guochun;Hu, Leilei;Lu, Yong;Kafle, Yuba Raj
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.654-663
    • /
    • 2012
  • In this paper, a digital control strategy based on equivalent fundamental and odd harmonic resonators is proposed for single-phase DVRs. By using a delay block, which can be equivalent to a bank of resonators, it rejects the fundamental and odd harmonic disturbances effectively. The structure of the single closed-loop control system consists of a delay block, a proportional gain and a set of zero phase notch filters. The principle of the controller design is discussed in detail to ensure the stability of the system. Both the supply voltage and the load current feedforwards are used to improve the response speed and the ability to eliminate disturbances. The proposed controller is simple in terms of its structure and implementation. It has good performances in harmonic compensation and dynamic response. Experimental results from a 2kW DVR prototype confirm the validity of the design procedure and the effectiveness of the control strategy.

Enhanced Startup Diagnostics of LCL Filter for an Active Front-End Converter

  • Agrawal, Neeraj;John, Vinod
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1567-1576
    • /
    • 2018
  • The reliability of grid-connected inverters can be improved by algorithms capable of diagnosing faults in LCL filters. A fault diagnostic method during inverter startup is proposed. The proposed method can accurately generate and monitor information on the peak value and the location of the peak frequency component of the step response of a damped LCL filter. To identify faults, the proposed method compares the evaluated response with the response of a healthy higher-order damped LCL filter. The frequency components in the filter voltage response are first analytically obtained in closed form, which yields the expected trends for the filter faults. In the converter controller, the frequency components in the filter voltage response are computed using an appropriately designed fast Fourier transform and compared with healthy LCL response parameters using a finite state machine, which is used to sequence the proposed startup diagnostics. The performance of the proposed method is validated by comparing analytical results with the simulation and experimental results for a three-phase grid-connected inverter with a damped LCL filter.

Recognition of Material Temperature Response Using Curve Fitting and Fuzzy Neural Network

  • Ryoo, Young-Jae;Kim, Seong-Hwan;Chang, Young-Hak;Lim, Yong-Cheol;Kim, Eui-Sun;Park, Jin-Kyn
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권2호
    • /
    • pp.133-138
    • /
    • 2001
  • This paper describes a system that can used to recognize an unknown material regardless of the change of ambient tem-perature using temperature response curve fitting and fuzzy neural network(FNN). There are some problems to realize the recogni-tion system using temperature response. It requires too many memories to store the vast temperature response data and it has to be filtered to remove noise which occurs in experiment. And the temperature response is influenced by the change of ambient tempera-ture. So, this paper proposes a practical method using curve fitting the remove above problems of memories and nose. And FNN is propose to overcome the problem caused by the change of ambient temperature. Using the FNN which is learned by temperature responses on fixed ambient temperature and known thermal conductivity, the thermal conductivity of the material can be inferred on various ambient temperature. So the material can be recognized by the thermal conductivity.

  • PDF

퍼지-PLL 제어기를 이용한 응답특성 개선 (Improvement of the Response Characteristics Using the Fuzzy-PLL Controller)

  • 조정환;서춘원
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.175-181
    • /
    • 2005
  • 본 논문에서는 자동화 시스템의 고속 정밀 제어를 위한 퍼지-PLL 제어기를 제안한다. 기존의 PLL 제어기는 넓은 데드존 때문에 지터 잡음을 발생하고, 긴 지연시간 때문에 고속 동작의 정밀제어에는 부적합 하다. 본 논문에서는 이러한 문제를 해결하기 위하여, 제어영역을 고속 제어와 정밀제어 영역으로 구분한다. 먼저 퍼지 제어 기법을 적용하여 신속한 과도응답을 수행하고, 오차가 설정된 범위에 진입하면 새로운 위상 주파수 검출기를 설계한 PLL 제어기를 사용하여 정밀제어를 수행한다. 제안된 다중 구조의 위상 주파수 검출기는 데드존과 지터 잡음을 개선하고, 상승 에지에서 동작하는 P-PFD와 하강 에지에서 동작하는 N-PFD로 구성하여 PLL의 응답 특성을 향상 시킨다.

다양한 IDT 구조에 따른 SAW 필터의 특성 연구 (Characterization of SAW filters with different IDT structures)

  • 신양호;김귀현;이진복;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1962-1964
    • /
    • 1999
  • Effect of IDT structures on the frequency response of the SAW device are investigated. Various types of IDTs, such as MSC(multistrip-coupler), double split, reflector, and ground line. are designed and patterned on the widely used Y-Z cut LN$(LiNbO_3)$ substrate. Center frequencies, band widths, and insertion losses are measured and compared. Invalidity of the conventional model based on the impulse response model is also discussed.

  • PDF

전기통신설비를 위한 옥내외 겸용 면진테이블 설계 (Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment)

  • 이춘세;안형준;이택원;손인철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF

Copper-tetra-tert-butylphthalocyanine(CuTBP) LB막의 온도에 따른 $NO_2$가스 탐지 특성에 관한 연구 (A Study on the $NO_2$ Gas-Detection properties of The Copper-tetra-tert-butylphthalocyanine(CuTBP) depending on the temperatures)

  • 한영재;이창희;김영관;김태완;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1223-1225
    • /
    • 1995
  • The $NO_2$ gas-detection characteristics were investigated using the functional organic Langmuir-Blodgett(LB) films of Copper-tetra-tert-butylphthalocyanine(CuTBP). The optimum conditions for a film deposition were obtained through a study of $\pi$-A isotherms, and the deposited film status was confirmed by the ellipsometry measurements. The $NO_2$ gas response experiments under 200 ppm concentration at room temperature show that there are increment of electrical conductivity by 40 times and 25 seconds of response time, and 40 seconds of recovery times.

  • PDF