• Title/Summary/Keyword: Electrical Isolation

Search Result 617, Processing Time 0.021 seconds

Satellite Fault Detection and Isolation Scheme with Modified Adaptive Fading EKF

  • Lim, Jun Kyu;Park, Chan Gook
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1401-1410
    • /
    • 2014
  • This paper presents a modified adaptive fading EKF (AFEKF) for sensor fault detection and isolation in the satellite. Also, the fault detection and isolation (FDI) scheme is developed in three phases. In the first phase, the AFEKF is modified to increase sensor fault detection performance. The sensor fault detection and sensor selection method are proposed. In the second phase, the IMM filer with scalar penalty is designed to detect wherever actuator faults occur. In the third phase of the FDI scheme, the sub-IMM filter is designed to identify the fault type which is either the total or partial fault. An important feature of the proposed FDI scheme can decrease the number of filters for detecting sensor fault. Also, the proposed scheme can classify fault detection and isolation as well as fault type identification.

An Approach for High Voltage Battery Voltage Sensing of Plug-In Hybrids and Battery Electric Vehicle (플러그인 하이브리드 및 전기 자동차 고압배터리 전압 측정 방법)

  • Kwon, Youngsung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.140-144
    • /
    • 2019
  • This paper proposes an approach for measuring voltage of high voltage(HV) battery of plug-in hybrid electric vehicle(PHEV) and battery electric vehicle(BEV). The proposed methods use isolation resistor and isolation amplifier in order to measure high voltage which should be electrically separated from measuring circuit. In terms of practical applications their advantages and disadvantage are discussed and key design points are addressed by simulations. More importantly, the proposed methods are applicable to various applications such as on-board charger, inverter and battery management system (BMS) which are directly connected to HV battery in PHEV and BEV.

Optimal In-Plane Configuration of 3-axis MEMS IMUs Considering Fault Detection and Isolation Performance and Lever Arm Effect (레버암 효과와 고장 감지 및 배제 성능을 고려한 여분의 3축 MEMS IMU의 평면 배치 기법)

  • Kim, Eung Ju;Kim, Yong Hun;Choi, Min Jun;Song, Jin Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1648-1656
    • /
    • 2018
  • The configuration of redundant inertial sensors are very important when considering navigation performance and fault detection and isolation (FDI) performance. By constructing a redundant sensor system using multiple inertial sensors, it is possible to improve the navigation performance and fault detection and isolation performance, which are highly related to the sensor configuration and allocation. In order to deploy multiple MEMS inertial measurement units effectively, a configuration and allocation methods considering navigation performance, fault detection and isolation performance, and lever arm effect in one plane are presented, and the performance is analyzed through simulation in this research. From the results, it is confirmed that the proposed configuration and allocation method can improve navigation, FDI, and lever arm effect rejection performances more effectively by more than 70%.

집적회로에서의 isolation

  • 김충기
    • 전기의세계
    • /
    • v.24 no.6
    • /
    • pp.32-34
    • /
    • 1975
  • 집적회로에서는 한개의 silicon chip위에 여러개의 소자를 동시에 제작한 후 이들 소자를 상호 연결하여 하나의 회로를 구성한다. 이때 소자간의 불필요한 상호작용을 제거하기 위하여 각각의 소자는 Isolate되어 있어야 한다. 집적회로가 아닌 일반회로에서는 각각의 소자를 따로 제작하여 회로기판에서 연결하므로 소자간의 Isolation은 기판과 공기에 의해 이루어 진다. 그러나 집적회로에서는 각 소자가 수 10.mu.정도의 간격을 두고 동일한 Chip상에 있으므로 각 소자간의 Isolation을 위하여 특별한 기술을 사용하여야 한다. 본 논문에서는 집적회로에서 사용되는 몇가지 Isolation방법을 소개하고자 한다.

  • PDF

An Ultra Wideband, Novel and Reliable RF MEMS Switch

  • Jha, Mayuri;Gogna, Rahul;Gaba, Gurjot Singh;Miglani, Rajan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.183-188
    • /
    • 2016
  • This paper presents the design and characterization of wide band ohmic microswitch with an actuation voltage as low as 20~25 V, and a restoring force of 14.1 μN. The design of the proposed switch is primarily composed of an electrostatic actuator, bridge membrane, cantilever (beam) and coplanar waveguide, suspended over the substrate. The analysis shows an insertion loss of −0.002 dB at 1GHz and remains as low as −0.35 dB, even at 100 GHz. The isolation loss of the switch is sustained at −21.09 dB at 100GHz, with a peak value of −99.58 dB at 1 GHz and up-state capacitance of 4 fF. To our knowledge, this is the first demonstration of a series contact switch, which works over a wide bandwidth (DC-100 GHz) and with such a high and sustained isolation, even at high frequencies and with an excellent figure of merit (fc=1/2.pi.Ron.Cu= 39.7 THz).

Signal Analysis of Motor Current for End Point Detection in the Chemical Mechanical Polishing of Shallow Trench Isolation with Reverse Moat Structure

  • Park, Chang-Jun;Kim, Sang-Yong;Seo, Yong-Jin
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.5
    • /
    • pp.262-267
    • /
    • 2002
  • In this paper, we first studied the factors affecting the motor current (MC) signal, which was strongly affected by the systematic hardware noises depending on polishing such as pad conditioning and arm oscillation of platen and recipe, head motor. Next, we studied the end point detection (EPD) for the chemical mechanical polishing (CMP) process of shallow trench isolation (STI) with reverse moat structure. The MC signal showed a high amplitude peak in the fore part caused by the reverse meal. pattern. We also found that the EP could not be detected properly and reproducibly due to the pad conditioning effect, especially when conventional low selectivity slurry was used. Even when there was no pad conditioning effect, the EPD method could not be applied, since the measured end points were always the same due to the characteristics of the reverse moat structure with an open nitride layer.

H_/H Sensor Fault Detection and Isolation of Uncertain Time-Delay Systems

  • Jee, Sung Chul;Lee, Ho Jae;Kim, Do Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.313-323
    • /
    • 2014
  • Sensor fault detection and isolation problems subject to H_/$H_{\infty}$, performance are concerned for linear time-invariant systems with time delay in a state and parametric uncertainties. To that end, a model-based observer bank approach is pursued. The design conditions for both continuous- and discrete-time cases are formulated in terms of matrix inequalities, which are then converted to the problems solvable via an algorithm involving convex optimization.

Fault Isolation for a Diesel Engine Actuator (디젤엔진 위치서보시스템을 위한 고장 식별)

  • Park, Tae-Geon;Hur, Hak-Bom;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.417-419
    • /
    • 1998
  • In a large diesel engine actuator position servo system, it is impossible to isolate an actuator fault from a load torque with conventional fault detection isolation (FDI) schemes because they are propagated through a channel. This paper deals with a parity equation based residual generation to isolate them in the system. The actuator fault is modelled by a multiplicative type fault that can be characterized as discrepancies between the nominal and actual plant parameters, whereas the load torque is modelled by an additive disturbance. The transformation implemented in the residual generator should be determined on-line to achieve the isolation. Simulation studies show the practical applicability of the FDI scheme.

  • PDF

Determination of End Point for Direct Chemical Mechanical Polishing of Shallow Trench Isolation Structure

  • Seo, Yong-Jin;Lee, Kyoung-Jin;Kim, Sang-Yong;Lee, Woo-Sun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.1
    • /
    • pp.28-32
    • /
    • 2003
  • In this paper, we have studied the in-situ end point detection (EPD) for direct chemical mechanical polishing (CMP) of shallow trench isolation (STI) structures without the reverse moat etch process. In this case, we applied a high selectivity $1n (HSS) that improves the silicon oxide removal rate and maximizes oxide to nitride selectivity Quite reproducible EPD results were obtained, and the wafer-to-wafer thickness variation was significantly reduced compared with the conventional predetermined polishing time method without EPD. Therefore, it is possible to achieve a global planarization without the complicated reverse moat etch process. As a result, the STI-CMP process can be simplified and improved using the new EPD method.