• Title/Summary/Keyword: Electrical Characteristic Measurement

Search Result 367, Processing Time 0.024 seconds

CO Gas Response Characteristic and Electrical Properties of ZnO-TiO$_2$Composite (ZnO-TiO$_2$ 복합체의 전기적 성질과 일산화탄소 감응특성)

  • 김태원;최우성;박춘배;정승우;소병문;백승철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.103-106
    • /
    • 1997
  • The electrical properties and the sensing properties of ZnO-TiO$_2$ composites were investigated by using the complex impedance measurement and voltage-current source and measurement unit. In air, the electrical conductivity of TiO$_2$ added ZnO increase with increasing the content of TiO$_2$ and the relative dielectric constants for 3, 5 and 7mol% TiO$_2$ added ZnO are 7, 13 and 120, respectively. In 3000ppm CO gas, the relative dielectric constants for 3, 5mol% TiO$_2$ added ZnO are 25, 28, respectively.

  • PDF

A Study on the Analysis of the Magnetic Fields Generated by the operation of Electric Appliances (전기기구의 운전중에 발생되는 자계성분해석에 관한 연구)

  • Lee, Bok-Hee;Park, Hyung-Ki;Chung, Seung-Soo;Paek, Yong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.575-577
    • /
    • 1993
  • In this study, the reponse characteristic of the time-changing magnetic field measurement system by using the self-integrated magnetic sensor is investigated. The measurement system has the frequency bandwidth of 40[Hz]-50[kHz]. The time-changing magnetic fields generated by the operations of small-size electric machines are investigated. The magnetic field generated by the starting and/or the operation of electric appliances mainly includes the odd harmonics such as the third, the fifth, the seventh, and so on.

  • PDF

Analysis of Torque Characteristics for the Single-phase Induction Motor Considering Space Harmonics

  • Kim Byung-Taek;Lee Sung-Ho;Kwon Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.327-331
    • /
    • 2006
  • This paper presents the analysis method for the torque characteristic of the 1-phase induction motor considering space harmonics in the air gap. The equivalent circuit method is used, where the circuit constants are obtained by classic theory. In addition, the space harmonic components in air gap magneto motive force are analyzed and added to the equivalent circuit to obtain accurate torque characteristics in low speed regions. Each torque component due to the harmonics is calculated and the total torque characteristic is obtained and compared with the measurement result.

High Precise Measurement of Grid-Connected Inverter using DFT (DFT를 이용한 계통연계 인버터 시스템의 고정밀 계측)

  • Lee, Sang-Hyeok;Kang, Feel-Soon;Lee, Sang-Hun;Cho, So-Eog;Lee, Tae-Won;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • A precise measurement of the grid voltage is one of the essential techniques, which is required to connect a renewable energy to the grid. In general, when a filter is used to eliminate unnecessary harmonics and noises, a signal is distorted by phase delay, amplitude attenuation, and other distortions. And the response characteristic of a controller is directly affected by bandwidth of cut-off frequency of the filter. To alleviate this problems, we propose an effective algorithm based on DFT(Discrete Fourier Transform) instead of approaching the filter application. The proposed algorithm ensures high precise measurement of the grid voltage because it can extract the fundamental and harmonics from the raw signal without any distortions. The high performance of the proposed algorithm is verified by PSIM simulation and experiments of Grid-Connected VSI.

Effect of Wall Groove Characteristics on Yield Stress Measurement of Magnetorheological Fluid

  • Tian, Zuzhi;Guo, Chuwen;Chen, Fei;Wu, Xiangfan
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.281-285
    • /
    • 2017
  • To suppress the wall slip effect and improve the yield stress measurement precision of magnetorheological fluid, measurement disks with different grooves are first manufactured. Then, the influence of groove characteristics on the yield stress of magnetorheological fluid is investigated by the method of experiments. Finally, the optimization wall grooves of measurement disks are obtained, and the yield stress of a self-prepared magnetorheological fluid is measured. Results indicate that the groove type and groove width have a slight influence on the shear yield stress, whereas the measured yield stress increases with enhanced groove density, and the optimized groove depth is 0.3 mm. The measured shear yield stress of self-prepared MR fluid can be improved by 18 % according to the optimized grooved disks, and the maximum yield stress can reach up to 65 kPa as the magnetic flux density is 0.5 T.

Development of Power Supply Device for Load Characteristic Experimentation (부하특성실험을 위한 전원공급장치 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.101-107
    • /
    • 2005
  • The reduced power quality due to some of disturbances on power system has great influence on the efficient and life of load for bad with serious economic loss. The response of load about disturbance needs to analysis quantitatively in detail to improve load characteristics. In this research, a power supply device is developed to supply disturbed power similar to that of power system. The developed device can output a voltage and frequency from 180[V] to 240[V], 55[Hz] to 65[Hz] respectively. The most outstanding feature of this device is a function to be performed steady and dynamic state characteristic experiment on load or appliances. Also, this device is designed to include high accuracy ouput and simple measurement.

Development of Plasma Assisted ALD equipment and electrical characteristic of TaN thin film deposited PAALD method (Plasma Assisted ALD 장비 계발과 PAALD법으로 증착 된 TaN 박막의 전기적 특성)

  • Do Kwan-Woo;kim Kyoung-Min;Yang Chung-Mo;Park Seong-Guen;Na Kyoung-Il;Lee Jung-Hee;Lee Jong-Hyun
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.139-145
    • /
    • 2005
  • In the study, in order to deposit TaN thin film using diffusion barrier and bottom electrode we made the Plasma Assisted ALD equipment and confirmed the electrical characteristic of TaN thin films deposited PAALD method, PAALD equipment depositing TaN thin film using PEMAT(pentakis(ethylmethlyamlno) tantalum) Precursor and $NH_3$ reaction gas is aware that TaN thin film deposited of high density and amorphous phase with XRD measurement The degree of diffusion and react ion taking place in Cu/TaN(deposited using 150 W PAALD)/$SiO_2$/Si systems with increasing annealing temperature was estimated from MOS capacitor property and the $SiO_2(600\;\AA)$/Si system surface analysis by C-V measurement and secondary ion material spectrometer(SIMS) after Cu/TaN/$SiO_2(400\;\AA)$ system etching. TaN thin film deposited PAALD method diffusion barrier have a good diffusion barrier property up to $500^{\circ}C$.

  • PDF

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

Artificial contaminated test method and leakage current characteristics of EHV insulators (송전용 애자의 인공오손시험 기법과 누설전류 특성)

  • Choi, In-Huyk;Jung, Yoon-Hwan;Choi, Jang-Hyun;Lee, Dong-Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.386-391
    • /
    • 2004
  • To find out the reason of accident by being stained of insulators, this paper researched and analyzed the result of electrical characteristic test and field test of EHV insulator through artificial contaminated method. The best way to evaluate contaminated level of insulator surface is getting a contamination data by regional groups continually. But it is needed a lot of time and manpower. To overcome those difficulties, this research introduced ESDD(equivalent salt deposit density) measurement method which is adapted to the international codes of IEC and compared the relation between experimental test results which contaminated insulators by going through stain procedure and electrical measurement results.

  • PDF