• Title/Summary/Keyword: Electric Power Reduction System

Search Result 339, Processing Time 0.031 seconds

Analysis and Performance Test of Hybrid Transformer used in the Grid-Connected Photovoltaic Generation System (태양광 계통연계형 하이브리드 변압기의 해석 및 성능시험)

  • Kim, Ji-Ho;Park, Hoon-Yang;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.333-338
    • /
    • 2014
  • This paper concerns the development of the transformer that can reduce harmonics supplied to the system if the output of photovoltaic inverter in the photovoltaic system is grid-connected, and suggests that problems of harmonics and power factor degradation in the grid-connected photovoltaic system can be improved. In this study, the burden of increasing the investment in new facilities and securing their installation space due to harmonics has been substantially eased through the development of a hybrid transformer possessing unbalanced function and harmonics reduction function using zig-zag coils, and most of all, it is expected that the development of such high efficiency hybrid transformer possessing functions of transformation and reducing harmonics can improve the power quality as well as prevent damages caused by harmonics, leading to suppress unnecessary loss of electric power and thereby contribute to energy savings.

A Study on the Electromagnetic Transients at Switching Capacitor Banks in a Electric Distribution Electric Power Distribution Substation (배전변전소에서 캐패시터 뱅크 투입시 일어나는 전자과도 현상에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.92-99
    • /
    • 2002
  • Transient in an electric distribution system are mainly generated by switching. This paper presents analysis of switching surge and means of limiting the voltage magnification transient for high voltage power systems by using the EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor contraction capacitor banks to harmonics filters. An inductance in series with the capacitor bank was used to decrease the transient voltage at the customer bus to acceptable levels. And also simulation results used the EDSA harmonics analysis program show the effect of harmonics reduction.

Analysis on Operating Characteristics according to Applied Location of SFCL in a Power Transmission System (모의송전계통에서 고장전류 저감을 위한 초전도한류기 적용위치에 따른 동작특성 분석)

  • Lee, Hyeong-Jin;Park, Han-Min;Kim, Jin-Seok;Sung, In-Je;Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1104-1105
    • /
    • 2015
  • Recently, electric power demand increase due to the rapid industrial development. As a result, a power system has been expanded and fault currents are raised. Fault current is detriment effect on protective equipment. Superconducting fault current limiter(SFCL) is one of the solution to solve the fault current reduction. This paper analyzed operating characteristics according to applied location of SFCL in a transmission power system through the PSCAD/EMTDC simulation.

  • PDF

Electric Power Demand Prospect Pattern System (전력 수요 예측 패턴 시스템 설계)

  • Yu, seung-hyun;Lee, joung-myung;Park, han-ho;Kwak, nae-joung;Lee, hyun-tae;Jeon, jae-sung
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.112-115
    • /
    • 2008
  • Recently, In Korea Electric power Corporation guarantee free using, which separate a class of electric supply with a group of generates electricity and supply, so a market price is decided by demand and supply that take part in a tender. In this treatise predict about demand of power by abstracting a pattern cause it (temperature and economic growth). Also it proposes market price of the best electricity power generation with predicted data that is made database and is showed by Web. The proposed system is increased satisfaction of consumer through smoothness of power supply and demand that rises competitiveness through exactly estimated demand at power supply and demand and supply market will open the future. Moreover consumers can reduce expenses of basic charge. Because they beforehand predict and analyze a mount of power spending with former times so a provider concludes the lowest price and reduction effect of basic charge that needed producing of power.

  • PDF

Design and Implementation of User Pattern based Standby Power Reduction System Applying Zigbee-MQTT in a Smart Building Environment (스마트빌딩 환경에서 Zigbee-MQTT를 이용한 사용자 패턴 기반 대기전력 저감 시스템 설계 및 구현)

  • Jang, Young-Hwan;Lee, Sang-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1158-1164
    • /
    • 2020
  • In Korea, the dependence on imported energy is very high, and research to reduce standby power is being conducted based on Zigbee, a low-power technology, to reduce wasted power and improve power efficiency. However, because Zigbee is not an IoT standard protocol and is not network-based, it is necessary to build a network with a separate gateway, and research on standby power is insufficient because the standards for international power consumption of devices are ambiguous. Therefore, in this paper, we applied the IoT standard protocol MQTT to the existing Zigbee technology to build a network network without a separate gateway, and designed and implemented a standby power reduction system that collects standby power degradation and user patterns. As a result of evaluating with the existing system, it was confirmed that about 7.11% of standby power was consumed compared to the existing system.

A Study on the Integration Costs in Korean Electric System in Accordance with Increasing Solar and Wind Power Generation (태양광·풍력 발전 증가에 따른 한국의 전력시스템 내 통합비용에 관한 연구)

  • Kim, Doo Chun;Kim, Kwang Jin;Park, Jung Gu
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.42-54
    • /
    • 2019
  • The solar and wind power is spreading as a means to $CO_2$ reduction, but it has the characteristics of the volatility depending on the weather changes. This article aims to estimate the additional integration costs in Korea electric system in response to such volatility of increasing solar and wind power generation, using Korea electric power trading analyzer(KEPTA). The analysis utilizes the statistics of "8th Basic Plan for Long-term Electricity Supply and Demand" and "Renewable Energy Plan 3020". As the results, integration costs will be estimated 13.94Won/kWh~32.55Won/kWh, consisting of 8.94Won/kWh as back-up costs, 1.03Won/kWh~4.45Won/kWh as balancing costs, and 3.97Won/kWh~19.16Won/kWh as grid-costs. These results suggest that when the integration costs are secured, Korea electric system will be expected in the stable situation. This article leaves the further studies with taking the technological development of solar and wind power generation, the introduction of energy storage system, and wholesale price of electricity into consideration.

Study on Equivalent Consumption Minimization Strategy Application in PTI-PTO Mode of Diesel-Electric Hybrid Propulsion System for Ships

  • Lee, Dae-Hong;Kim, Jong-Su;Yoon, Kyoung-Kuk;Hur, Jae-Jung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.3
    • /
    • pp.451-458
    • /
    • 2022
  • In Korea, five major ports have been designated as sulfur oxide emission control areas to reduce air pollutant emissions, in accordance with Article 10 of the "Special Act on Port Air Quality" and Article 32 of the "Ship Pollution Prevention Regulations". As regulations against vessel-originated air pollutants (such as PM, CO2, NOx, and SOx) have been strengthened, the Ministry of Oceans and Fisheries(MOF) enacted rules that newly built public ships should adopt eco-friendly propulsion systems. However, particularly in diesel-electric hybrid propulsion systems,the demand for precise control schemes continues to grow as the fuel saving rate significantly varies depending on the control strategy applied. The conventional Power Take In-Power Take Off(PTI - PTO) mode control adopts a rule-based strategy, but this strategy is applied only in the low-load range and PTI mode; thus, an additional method is required to determine the optimal fuel consumption point. The proposed control method is designed to optimize fuel consumption by applying the equivalent consumption minimization strategy(ECMS) to the PTI - PTO mode by considering the characteristics of the specific fuel oil consumption(SFOC) of the engine in a diesel-electric hybrid propulsion system. To apply this method, a specific fishing vessel model operating on the Korean coast was selected to simulate the load operation environment of the ship. In this study, a 10.2% reduction was achieved in the MATLAB/SimDrive and SimElectric simulation by comparing the fuel consumption and CO2 emissions of the ship to which the conventional rule-based strategy was applied and that to which the ECMS was applied.

An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System (도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가)

  • Jung, Hosung;Kim, Joouk;Shin, Seongkuen;Kim, Hyungchul;An, Taepung;Yun, Junseok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

Development of the ultra-high speed electric injection molding machine using the energy regeneration method (에너지 회생 기법을 사용한 초고속 전동 사출성형기 개발)

  • Yu, Hyeon-Jae;Yoo, Sung-Chul;Hyun, Chang-Hoon;Park, Kyoung-Ho
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2016
  • High-speed and high-torque performance is required in the ultra-high speed electric injection molding machine field. To implement this performance, the big-size inverter is needed and the corresponding converter should be used. In this case, the whole cost for configuring the system will be increased. In this paper, we introduce a method which is able to reduce the energy and the cost for configuring the system using the energy regeneration. The energy regeneration method is based on reusing the regeneration power generated at the electric motor during decelerating the injection motion. In this paper, we demonstrate the effectiveness of the method by using the ultra-high speed injection motion.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.