• Title/Summary/Keyword: Electric Line

Search Result 1,916, Processing Time 0.032 seconds

Automatic Assembly Task of Electric Line Using 6-Link Electro-Hydraulic Manipulators

  • Kyoungkwan Ahn;Lee, Byung-Ryong;Yang, Soon-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1633-1642
    • /
    • 2002
  • Uninterrupted power supply has become indispensable during the maintenance task of active electric power lines as a result of today's highly information-oriented society and increasing demand of electric utilities. The maintenance task has the risk of electric shock and the danger of falling from high place. Therefore it is necessary to realize an autonomous robot system using electro-hydraulic manipulator because hydraulic manipulators have the advantage of electric insulation. Meanwhile it is relatively difficult to realize autonomous assembly tasks particularly in the case of manipulating flexible objects such as electric lines. In this report, a discrete event control system is introduced for automatic assembly task of electric lines into sleeves as one of the typical task of active electric power lines. In the implementation of a discrete event control system, LVQNN (linear vector quantization neural network) is applied to the insertion task of electric lines to sleeves. In order to apply these proposed control system to the unknown environment, virtual learning data for LVQNN is generated by fuzzy inference. By the experimental results of two types of electric lines and sleeves, these proposed discrete event control and neural network learning algorithm are confirmed very effective to the insertion tasks of electric lines to sleeves as a typical task of active electric power maintenance tasks.

Development of Monitoring and Control System of Utility-Pipe Conduit (Power Tunnel) using PLC

  • Lee, Tae-Young;Park, Byung-Seok;Ju, Seong-Ho;You, Dong-Hee;Lim, Yong-Hoon;Song, Seok-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.116-119
    • /
    • 2004
  • The existing monitoring and control systems of utility-pipe conduit (power tunnel, cable tunnel etc) have established communication lines using optical fiber, leaky coaxial cable (LCX), and several kinds of control cable. Due to the properties of the used media, the cost of equipment is considerably high and the maintenance of the system is difficult. Also, the term of carrying out is long so that the extension of the system is in difficulty. Now it is desirable to adopt Power Line Communication (hereinafter, PLC) technology in the monitoring and control systems and use the existing low-voltage power-line for lamplight as communication line. This will lead the reduction of the construction cost and the easy maintenance of the system. In this paper, we research the characteristics of PLC in conduit, design and manufacture the field test system, and analyze the performance of the system by field test. Then, we introduce the reliable monitoring and control system of utility-pipe conduit using PLC.

  • PDF

Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire (중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발)

  • Kwak, Dong-Kurl;Kim, Jin-Hwan;Lee, Bong-Seob
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성)

  • Kim, Hee-Dong;Ju, Young-Ho;Yoon, Dea-Hen
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

A Running and Transient state Test of VVVF Inverter using A Inertia Load in Electric car (관성부하를 이용한 전동차용 VVVF인버터의 모의주행 및 과도상태시험)

  • 정만규;정기찬;고영철;방이석;서광덕
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.282-286
    • /
    • 1999
  • This paper presents a vector control of parallel drive, a beatless control and a low switching PWM technique for the propulsion system of Electric car as transient state which are included interrupting line voltage, changing line voltage slowly, suddenly, regenerating light load and starting from backward running. Improved performance and a validation of proposed method is shown by the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons electric cars through a running and transient state test.

  • PDF

Neutral Current Reduction Method Using Single-Phase Inverter (단상 인버터를 사용한 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jao-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.155-157
    • /
    • 2005
  • This paper analyzed the adoption possibility of a low cost single phase active power filter as the neutral current reduction device in three-phase four-wire power system with the balanced or/and unbalnaced nonlinear load conditions. Proposed system can make neutral line current to within rated vale without the phase current THD change of the installed phase line.

  • PDF

A Study on the Network Design of Electric Railway for Power Line Communication (전기철도의 전력선 통신망 설계에 관한 연구)

  • Kim, Jae-Moon;Kim, Yang-Su;Ahn, Seung-Ho;Lee, Hui-Jun;Lee, Jong-Gu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3756-3760
    • /
    • 2010
  • In this paper we propose network design for power line communication of electric railway using messenger wire. we carried out feasibility study on the power line communication(PLC) using Contact wire and messenger wire which are required at electric railway. First of all, full-duplex data communication was implemented using coupler which is suspended on messenger wire at non-voltage state. We verified data transfer rate was found to be good, and then proposed a design example of PLC network as the main components for PLC. we will study continuously make an effort to verify on the network design of PLC for further study.

The study on slipping down phenomenon of 345kv XLPE cable in inclinatior (경사지에서의 345kV XLPE $1C{\times}2000mm^2$ 케이블 코아 활락 현상 연구)

  • Baek, J.H.;Nam, S.H.;Lee, S.K.;Heo, H.D.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1782-1784
    • /
    • 2002
  • In this paper, the coefficient of friction betwee and sheath in 345kv XLPE cable was measured the simulated inclinated condition of You-Youngdeungpo transmission line. The phenomena of slipping down the simu inclination was investigated theoretically usin measured data and was analyzed from experim result. The measured and analyzed result were conside be as a reference data for real installation of XLPE Youngseo-Youngdeungpo transmission line.

  • PDF

Soil Breakdown Test using Fixture (Fixture를 이용한 토양 절연파괴 실험)

  • Lee, H.G.;Ha, T.H.;Jung, D.H.;Ha, Y.C.;Kim, D.K.;Bae, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF